Displaying 20 results from an estimated 42 matches for "200x200pels".
2003 Dec 11
2
FAX application does not work for me....
...Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 38 37 36 35 34 33 32 31 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Store and forward Internet fax: no
Real-time Internet fax: no
Preferred octets: 256
Can receive fax
Data signalling rate: V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Inch-based resolution preferred: no
Metric-based resolution preferred: no
Minimum scan line time for higher resolutions: T15.4 = T7.7...
2003 Oct 28
5
rxfax problem
...Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 38 37 36 35 34 33 32 31 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Store and forward Internet fax: no
Real-time Internet fax: no
Preferred octets: 256
Can receive fax
Data signalling rate: V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Inch-based resolution preferred: no
Metric-based resolution preferred: no
Minimum scan line time for higher resolutions: T15.4 = T7.7...
2004 Jun 18
0
Problems reciving fax with Asterisk
...to 1
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2003 Dec 07
5
RxFAX application
Hi all,
I have installed FAX app as described in several mails.
When a fax call is received, I get the following in the * console:
-- Starting simple switch on 'Zap/1-1'
-- Executing Answer("Zap/1-1", "") in new stack
-- Executing Ringing("Zap/1-1", "") in new stack
-- Executing Wait("Zap/1-1", "2") in new stack
2004 May 22
2
RxFAX generates no tiff file
...own
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed...
2004 Apr 19
3
spandsp/rxfax terminates asterisk
...carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9...
2004 May 31
2
scandsp, voicetronix and rxfx
...down
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2004 Apr 20
0
fwd:Re: Asterisk prepaid debug
...: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20
> > 20 20 20 20 20 20
> >
> > DIS:
> >
> > Preferred octets: 256
> >
> > Can receive fax
> >
> > Supported data signalling rates: V.27ter and V.29
> >
> > R8x7.7lines/mm and/or 200x200pels/25.4mm OK
> >
> > 2D coding OK
> >
> > Scan line length: 215mm
> >
> > Recording length: A4 (297mm)
> >
> > Receiver's minimum scan line time: 0ms at 3.85 l/mm:
> > T7.7 = T3.85
> >
> > R8x15.4lines/mm OK
> >
>...
2004 Jun 16
1
RxFax - Fast carrier training failed
...nged from phase 0 to 1
Slow carrier up
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2003 Nov 23
6
RxFax
...> Sending ident
> >>> CSI: 40 38 37 36 35 34 33 32 31 20 20 20 20 20 20 20 20 20 20 20
> 20
> DIS:
> Store and forward Internet fax: no
> Real-time Internet fax: no
> Preferred octets: 256
> Can receive fax
> Data signalling rate: V.29
> R8x7.7lines/mm and/or 200x200pels/25.4mm OK
> 2D coding OK
> Scan line length: 215mm
> Recording length: A4 (297mm)
> Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
> R8x15.4lines/mm OK
> Inch-based resolution preferred: no
> Metric-based resolution preferred: no
> Minimum scan line ti...
2004 Sep 21
0
more on spandsp and partially received fax
...to 1
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2003 Oct 28
1
Software FAX Modem--One Last Request For Help
...Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 38 37 36 35 34 33 32 31 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Store and forward Internet fax: no
Real-time Internet fax: no
Preferred octets: 256
Can receive fax
Data signalling rate: V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Inch-based resolution preferred: no
Metric-based resolution preferred: no
Minimum scan line time for higher resolutions: T15.4 = T7.7...
2004 Aug 16
0
SpanDSP - Training failed error / timing problem
...down
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2004 Aug 19
1
SpanDSP/RxFax help...
...down
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2004 Aug 13
1
SpanDSP - Training failed (convergence failed) error
...down
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29 R8x7.7lines/mm and/or
200x200pels/25.4mm OK 2D coding OK Scan line length: 215mm Recording
length: A4 (297mm) Receiver's minimum scan line time: 0ms at 3.85 l/mm:
T7.7 = T3.85 R8x15.4lines/mm OK Minimum scan line time for higher
resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed f...
2004 Mar 16
24
Softfax/spandsp
Hi all,
After a long time having no time, I have finally done some fresh work on
my software fax machine. I have replaced the original carrier tracking
with something more robust. I have also added 4800, and 2400 bits per
second modes, and cleaned up a few bugs in areas like superfine mode
operation. I apologise for this update taking so long.
At ftp://ftp.opencall.org/pub/spandsp you will
2005 Aug 12
0
txfax spandsp
...wn
Slow carrier up
Slow carrier down
Slow carrier up
Slow carrier down
Slow carrier up
<<< DIS: 80 00 ce f4 80 80 81 80 80 80 18
DIS with final frame tag
In state 10
DIS:
Prefer 256 octet blocks
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm
2D coding
Scan line length: 215mm
Recording length: Unlimited
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm
Minimum scan line time for higher resolutions: T15.4 = T7.7
North American Letter (215.9mm x 279.4mm)
North American Legal (215....
2004 Apr 21
1
TxFax/SpanDSP problems
...80 0c 01 02
NSF without final frame tag
The remote is made by 'Canon'
<<< DIS: 80 20 ee 88 c4 80 95 80 80 80 38
DIS with final frame tag
In state 10
DIS:
V.8 capable
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter, V.29 and V.17
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm) and B4 (364mm)
Receiver's minimum scan line time: 20ms at 3.85 l/mm: T7.7 = T3.85
Error correction mode
T.6 coding
R8x15.4lines/mm OK
R16x15.4lines/mm and/or 400x400pels/25.4 mm OK
Metric-based resolution preferred
Mini...
2003 Dec 16
2
Unable to Receive Fax -- RxFAX Application
...Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 38 37 36 35 34 33 32 31 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Store and forward Internet fax: no
Real-time Internet fax: no
Preferred octets: 256
Can receive fax
Data signalling rate: V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Inch-based resolution preferred: no
Metric-based resolution preferred: no
Minimum scan line time for higher resolutions: T15.4 = T7.7...
2005 May 24
3
rxfax(spandsp-0.0.2pre18) and HT488
Hi,
spandsp-0.0.2pre18 works fine for txfax with HT488(version-1.0.1.2),
but rxfax doesn't work. After some FAX sounds, it hangup!
Could someone tell me how to debug?
The following is the * CLI> log
to 192.168.0.161:43222
-- Executing NoOp("SIP/4881-bde9", "") in new stack
-- Executing RxFAX("SIP/4881-bde9",