Displaying 20 results from an estimated 7000 matches similar to: "Problem with E1"
2003 Sep 25
3
configuring TE410P for four E1 PRI lines
hi,
I'm trying to configure my newly acquired TE410P card to work as 4
E1 spans. This is
supposed to be a drop-in replacement to the earlier E100P card. However,
on loading the
zaptel module it gets configured as T1 spans basically doing a 'cat' on
/proc/zaptel/1 thru 4,
it shows 24 channels per span. After this ztcfg fails saying
'ZT_CHANCONFIG failed for channel 97'.
2004 Jun 14
3
No B-Channels. PRI. E100P. HELP!
Hi.
I still hace problems getting my line to work. When I
start asterisk, I can see:
== Parsing '/etc/asterisk/zapata.conf': Found
-- Registered channel 1, PRI Signalling signalling
...
-- Registered channel 31, PRI Signalling signalling
== Starting D-Channel on span 1
== Registered channel type 'Zap' (Zapata Telephony
2004 Oct 26
2
E1 configuration problem
Hi !
I'm trying to configurate my first asterisk system.
My test plant has an E100P Card and a 4 FXS TDM 400P card.
I've an E1 configured for 15 channels.
Telco says that crc4 is configurated so my zaptel.conf is:
loadzone = it
defaultzone=it
span=1,0,0,ccs,hdb3,crc4
bchan=1-15
dchan=16
unused=17-31
fxoks=32-35
zttool shows no alarms.
I've also tried changing the timing
2004 Aug 12
1
BRI and E1 in same system
Hi-
Anyone using the Junghann's quad BRI card and the Digium E100P in the same
system?
I'm having a configuration problem where I can configure the cards one at a
time (with the appropriate drivers loaded) in a system, but when I try them
both together, neither will work. They both work fine one at a time.
Probably has something to do with the channel numbering.
I've tried
2004 Aug 02
1
help with digium E1 card
Hola!
I've a Digium E1 card, zaptel recognizes it as (loading the module
with debug=1)
Setting up DMA (write/read = 321b2000/321b2200)
Controller version: 43
Framer: DS21554, Revision: 5 (E1)
Found a Wildcard: Digium Wildcard E100P E1/PRA
Using CCS/HDB3 coding/framing with CRC4 120 Ohms
Calling startup (flags is 4099)
Started DMA
Got interrupt: 0x0005
/etc/zaptel.conf:
2003 Sep 25
6
E1 in Brazil
Hey all!
I had an experience trying to set up an E1 in Brazil which could help
somebody. In Brazil is very common telcos to have just R2 digital as their
primary signaling. As I were trying to set up an E100P, which does not
support R2 yet, I had to test an other signaling which works perfectly with
Asterisk.
They call this signaling as RDSI, using ccs as framing and PA (primary
access) as
2004 Jan 04
2
Two E100P boards - could not load zaptel module - Channel 63 - no such device
Hi,
I have two E100P boards connected to my PC. I wish to setup two
E1-ISDN-PRI lines, the first SPAN with 15 channels and the second one
with 30 channels. When I try to load zaptel modules, I get an error message:
"Loading zaptel framework:
Loading zaptel hardware modules: wct1xxp wcusb
Running ztcfg: ZT_CHANCONFIG failed on channel 63: No such device"
Follows my zaptel.conf:
2003 Jul 11
0
[Q]: Dialin problems over E1 on a Digium E100P
Hi....
Apologies for the length of this, but any help would be greatly appreciated
;-)...
I have installed and configured a Digium E100P on my Asterisk PBX and I have
connected this to an 8 port E1 VoIP gateway on a Cisco 6509. There is also
an external E1 link from our Telco plugged into one of the other ports on
this gateway and this gateway is in turn registered with a Cisco CallManager
2004 Sep 03
5
Digium E100P and PMX in Germany
Hello ml,
i need some help on my zaptel configuration. My E100P only shows some
YELLOW / RED alarm when I load the wct1xxp module and do a
cat /proc/zaptel/1
Span 1: WCT1/0 "Digium Wildcard E100P E1/PRA Card 0" HDB3/CCS YELLOW RED
...
..
.
My /etc/zaptel.conf is:
span=1,1,0,ccs,hdb3
bchan=1-15,17-31
dchan=16
loadzone=nl
defaultzone=nl
I tried zaptel-1.0RC2 and the latest CVS
2003 Jul 11
7
ISDN PRI E1 configuration with E100P
<P>hi Everyone,</P>
<P>We are configuring an ISDN PRI E1 with an E100P card, when you load the drivers, and starts the asterisk, cards also starts fine, givin following output,</P>
<P>*CLI> <BR> == D-Channel on span 1 up<BR> -- B-channel 1 successfully restarted on span 1<BR> --
2004 May 31
2
Crc4 issues
Hi All,
This is our 2nd E1 client that we try to use crc4 either with the e100p
or with the e405p without luck.
After some trials, we ask the telco to switch off crc4 on their side and
everything works flawlessly.
Is there anything in the crc4 calculation that may be broken? We took a
look at wct1xxx.c and wct4xx.c but there doesn't seem to be much there
to be fixed (apparently the crc4
2004 Sep 16
2
Help with E1 configuration
Hi,
I currently have a E100P card installed on my machine and the E1
subscription will be activated pretty soon. However, I have no idea how to
configure asterisk to make inbound and outbound call using the E1.
Especially for extensions.conf. Below is the configuration I used for
zaptel.conf and zapata.conf. Is it possible if someone can verify if the
configuration for zaptel and zapata is
2003 Aug 21
0
Zaptel.conf & digium E100P
Hello,
Thanks to members of the list things changed on my installation
(asterisk + digium E100P with of course an E1 line).
Here is my zaptel.conf :
-
span=1,1,0,ccs,hdb3
bchan=1-15,17-31
dchan=16
loadzone=fr
defaultzone=fr
-
Output of zttool:
-
Alarms Span
YEL/RED Digium Wildcard E100P E1/PRA Card 0
-
[root@asterisk root]# head /proc/zaptel/1
Span 1: WCT1/0 "Digium
2004 Jun 24
0
2 E100P cards on one asterisk
Hello,
Is it possible to have 2 E100P cards on one asterisk?
I'm able to do that now, but I'm not sure about my config.
Here is my zaptel.conf
[root@ConnecteurPRI02 asterisk]# more ../zaptel.conf
span=1,1,0,ccs,hdb3
bchan=1-15,17-31
dchan=16
loadzone=fr
defaultzone=fr
span=1,2,0,ccs,hdb3
bchan=32-46,48-62
dchan=47
loadzone=fr
defaultzone=fr
Here is my zapata.conf
2004 Jun 01
1
E100P isdn pri installation
Hi,
I'm installing E100P for isdn pri line.
My configuration are like this.
zaptel.conf
=======================================
span=1,0,0,ccs,hdb3,crc4
loadzone = us
defaultzone=us
bchan=1-15
dchan=16
bchan=17-31
zapata.conf
=================================================
[channels]
context=default
switchtype=euroisdn
context=default
signalling=pri_net
usecallerid=yes
2007 Jun 28
2
E1 not coming up
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Hello List,
since some days i run into the problem that one span on a TE407P is not
comming up correctly. With intense debug on that span i get:
< [ 02 01 7f ]
< Unnumbered frame:
< SAPI: 00 C/R: 1 EA: 0
< TEI: 000 EA: 1
< M3: 3 P/F: 1 M2: 3 11: 3 [ SABME (set asynchronous balanced mode
extended) ]
< 0 bytes of data
2005 Jan 24
0
TDM400P Sync source
Hi,
I am trying to track down the reason to my problems with sending and reciving fax with my PRI and 2 TDM400P Cards:
PSTN <-> PRI (E100P) <-> * <-> TDM400P <-> Fax Machine
I have used Zapbarge to listen to the data stream, but I can't say if it really have some time slips - fax kinda noisy in itself.
Using the zttool i saw the Sync source for the TDM are
2004 Jun 12
2
Sending SABME continuosly. Urgent help needed!
Hi, I'm trying to install an E1 PRI, and I need it working by
Monday, but although everything seems ok, I get no response to calls.
When I make a pri extense debug on span 1, I repeatedly get the
following:
Sending Set Asynchronous Balanced Mode Extended
[ 00 01 7f ]
Unnumbered frame:
SAPI: 00 C/R: 0 EA: 0
TEI: 999 EA: 1
M3: 3
2005 Jan 25
2
Problems splicing Asterisk with a TE405P between Arcor E1 PRI and Ericsson Business Phone 250
hi,
i'm having problems getting asterisk spliced between an E1 PRI (german
Telco Arcor) and an Ericsson Business Phone 250 digital PBX.
The Asterisk Server has a TE405P with it's port 1 connected to the E1
PRI provided by our telecommunications provider Arcor and port 2
connected to the E1 PRI of our Ericsson BP250.
the setup before:
Arcor TelCo PRI(E1)
2010 Jul 19
1
Problem with E1
Hi All,
I am facing problem with E1 line. I have installed Asterisk
(1.4.20.1) on a system with Digium TE420 card (Zaptel- 1.4.10)
But every
now and then I face problem of down E1's. The log show lot of entries like
"pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of
span 2"
This happens on a regular basis and the E1 becomes up after some
time.
My