Dushan Tcholich
2011-Apr-28 09:43 UTC
[Nut-upsuser] Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Hello First things first, thanks for great work with NUT. For years I used Informer compact 3kVA UPS http://www.informups.com/informer_compact.html with nut/megatec serial driver, but it stopped working when I switched to blazer_ser with 2.6.0 upgrade. I'm using 2.6.0 on gentoo. Blazer_ser seems to connect with UPS, but upsmon reports driver not connected. uname -a Linux localhost 2.6.36-gentoo-r7 #3 SMP Tue Feb 8 18:39:54 CET 2011 x86_64 Intel(R) Core(TM)2 CPU 6400 @ 2.13GHz GenuineIntel GNU/Linux Configuration: cat ups.conf | grep "#" -v [munja] driver = blazer_ser port = /dev/ttyS0 cat upsd.conf | grep "#" -v LISTEN 127.0.0.1 3493 cat upsd.users | grep "#" -v [monuser] password = ####### cat upsmon.conf | grep "#" -v MONITOR munja at localhost 1 monuser ###### slave MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" NOTIFYCMD /usr/local/ups/bin/notifyme POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG /etc/killpower RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5 /lib64/nut/blazer_ser -DDDDD -a munja -i 10 Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.6.0) 0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0" 0.000051 debug level is '5' 0.100836 send_to_all: SETINFO device.type "ups" 0.100860 send_to_all: SETINFO driver.version "2.6.0" 0.100870 send_to_all: SETINFO driver.version.internal "1.51" 0.100879 send_to_all: SETINFO driver.name "blazer_ser" 0.100886 Trying megatec protocol... 0.100970 send: Q1 0.326638 read: (246.0 140.0 246.0 004 50.0 54.0 25.0 00001000 0.326681 send_to_all: SETINFO input.voltage "246.0" 0.326695 send_to_all: SETINFO input.voltage.fault "140.0" 0.326707 send_to_all: SETINFO output.voltage "246.0" 0.326730 send_to_all: SETINFO ups.load "4" 0.326741 send_to_all: SETINFO input.frequency "50.0" 0.326752 send_to_all: SETINFO battery.voltage "54.00" 0.326763 send_to_all: SETINFO ups.temperature "25.0" 0.326772 send_to_all: SETINFO beeper.status "disabled" 0.326782 send_to_all: SETINFO ups.type "offline / line interactive" 0.326792 send_to_all: SETINFO ups.status "OL" 0.326799 Status read in 1 tries 0.326806 Supported UPS detected with megatec protocol 0.326877 send: F 0.446626 read: #230.0 0.0 048.0 50.0 0.446660 send_to_all: SETINFO input.voltage.nominal "230" 0.446671 send_to_all: SETINFO input.current.nominal "0.0" 0.446683 send_to_all: SETINFO battery.voltage.nominal "48.0" 0.446694 send_to_all: SETINFO input.frequency.nominal "50" 0.446701 Ratings read in 1 tries 0.446773 send: I 0.634630 read: # IN03064B 0.634659 send_to_all: SETINFO ups.mfr "" 0.634669 send_to_all: SETINFO ups.model "" 0.634679 send_to_all: SETINFO ups.firmware "IN03064B" 0.634686 Vendor information read in 1 tries 0.634693 Battery runtime will not be calculated (runtimecal not set) 0.634702 send_to_all: SETINFO ups.delay.start "180" 0.634711 send_to_all: SETINFO ups.delay.shutdown "30" 0.634719 send_to_all: ADDCMD beeper.toggle 0.634726 send_to_all: ADDCMD load.off 0.634733 send_to_all: ADDCMD load.on 0.634740 send_to_all: ADDCMD shutdown.return 0.634748 send_to_all: ADDCMD shutdown.stayoff 0.634755 send_to_all: ADDCMD shutdown.stop 0.634763 send_to_all: ADDCMD test.battery.start 0.634776 send_to_all: ADDCMD test.battery.start.deep 0.634785 send_to_all: ADDCMD test.battery.start.quick 0.634793 send_to_all: ADDCMD test.battery.stop 0.634864 send: Q1 0.862632 read: (246.0 140.0 246.0 004 50.0 54.0 25.0 00001000 0.862677 send_to_all: DATAOK 0.862793 dstate_init: sock /var/lib/nut/blazer_ser-munja open on fd 5 0.862808 send_to_all: SETINFO driver.parameter.pollinterval "10" 0.862818 send_to_all: SETINFO device.mfr "" 0.862827 send_to_all: SETINFO device.model "" 0.862900 send: Q1 1.090631 read: (246.0 140.0 246.0 003 50.0 54.0 25.0 00001000 1.090670 send_to_all: SETINFO ups.load "3" 10.871363 send: Q1 11.098641 read: (246.0 140.0 246.0 005 50.0 54.0 25.0 00001000 11.098681 send_to_all: SETINFO ups.load "5" upsmon -DDDDD Network UPS Tools upsmon 2.6.0 0.000000 UPS: munja at localhost (slave) (power value 1) 0.000153 Using power down flag file /etc/killpower 0.000261 debug level is '5' 0.001301 Trying to connect to UPS [munja at localhost] 0.002166 Logged into UPS munja at localhost 0.002184 pollups: munja at localhost 0.002197 get_var: munja at localhost / status 0.002279 Poll UPS [munja at localhost] failed - Driver not connected 0.002290 do_notify: ntype 0x0005 (COMMBAD) 0.002297 Communications with UPS munja at localhost lost 5.002588 pollups: munja at localhost 5.002617 get_var: munja at localhost / status 5.002758 Poll UPS [munja at localhost] failed - Driver not connected 5.002771 do_notify: ntype 0x0008 (NOCOMM) 5.002781 UPS munja at localhost is unavailable 10.003015 pollups: munja at localhost 10.003048 get_var: munja at localhost / status 10.003191 Poll UPS [munja at localhost] failed - Driver not connected 15.003280 pollups: munja at localhost 15.003309 get_var: munja at localhost / status 15.003450 Poll UPS [munja at localhost] failed - Driver not connected What am I missing? Thanks for your time Dushan
Arjen de Korte
2011-Apr-28 11:41 UTC
[Nut-upsuser] Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Citeren Dushan Tcholich <dusanc op gmail.com>: [...]> /lib64/nut/blazer_ser -DDDDD -a munja -i 10 > Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.6.0) > 0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0"Looks fine. [...]> upsmon -DDDDD > Network UPS Tools upsmon 2.6.0 > 0.000000 UPS: munja op localhost (slave) (power value 1) > 0.000153 Using power down flag file /etc/killpower > 0.000261 debug level is '5' > 0.001301 Trying to connect to UPS [munja op localhost] > 0.002166 Logged into UPS munja op localhost > 0.002184 pollups: munja op localhost > 0.002197 get_var: munja op localhost / status > 0.002279 Poll UPS [munja op localhost] failed - Driver not connected > 0.002290 do_notify: ntype 0x0005 (COMMBAD) > 0.002297 Communications with UPS munja op localhost lost > 5.002588 pollups: munja op localhost > 5.002617 get_var: munja op localhost / status > 5.002758 Poll UPS [munja op localhost] failed - Driver not connected > 5.002771 do_notify: ntype 0x0008 (NOCOMM) > 5.002781 UPS munja op localhost is unavailable > 10.003015 pollups: munja op localhost > 10.003048 get_var: munja op localhost / status > 10.003191 Poll UPS [munja op localhost] failed - Driver not connected > 15.003280 pollups: munja op localhost > 15.003309 get_var: munja op localhost / status > 15.003450 Poll UPS [munja op localhost] failed - Driver not connected > > What am I missing?What is the output of 'upsd' in the syslog telling you? Note that when running in debug mode, a process will terminate as soon as you close the terminal it is running in or when you kill it with Ctrl-C. Best regards, Arjen -- Please keep list traffic on the list (off-list replies will be rejected)
Maybe Matching Threads
- Help with Aiptek PowerWalker VFI 1000 LCD and Konig CMP1200
- nut problem on boot/restart
- blazer_usb disconnects
- NUT support for CyberPower PR1500LCDRTXL2Ua
- [BUG] nut 2.4.3+: UPS EP-1K: Firmware fault: USB-Interface crashes with nut.org monitoring if driver polling time <15 sec