Displaying 20 results from an estimated 102 matches for "send_to_all".
2011 Mar 26
1
Help with Aiptek PowerWalker VFI 1000 LCD and Konig CMP1200
...ltage: 227.5
ups.delay.shutdown: 30
ups.delay.start: 180
ups.firmware: 00001907
ups.load: 15
ups.mfr:
ups.model: HV 1K
ups.productid: 5161
ups.status: OL BYPASS
ups.temperature: 20.5
ups.type: online
ups.vendorid: 0665
etwork UPS Tools - Megatec/Q1 protocol USB driver 0.03 (2.6.0)
0.000000 send_to_all: SETINFO driver.parameter.port
"/dev/bus/usb/007/002"
0.000041 debug level is '5'
0.305688 Checking device (1D6B/0002) (008/001)
0.305749 - VendorID: 1d6b
0.305756 - ProductID: 0002
0.305761 - Manufacturer: unknown
0.305765 - Produc...
2016 Jan 18
0
NUT support for CyberPower PR1500LCDRTXL2Ua
...23 50 52 31 35 30 30 4c 43 44 52 54 58 4c 32 55 61 20
> 0.608592 20 20 20 2c 34 2e 33 35 30 2c 50 53 55 45 56 32 30 30 30 31 31 33 2c 43 59
> 0.608620 42 45 52 20 50 4f 57 45 52
> 0.608645 CyberPower UPS with text protocol on /dev/ttyS0 detected
> 0.608679 send_to_all: SETINFO device.type "ups"
> 0.608709 send_to_all: SETINFO driver.version "2.6.5"
> 0.608761 send_to_all: SETINFO driver.version.internal "0.25"
> 0.608790 send_to_all: SETINFO driver.name "powerpanel"
> 0.608818 send_t...
2013 Sep 16
2
Zigor Ebro 650 compatibility - revisited (on Windows, at least)
...his (possibly not
very common) configuration.
Martyn
London.
--
"There are 10 types of people in this world. Those who understand binary and those who don't."
-------------- next part --------------
Network UPS Tools - Megatec/Q1 protocol USB driver 0.09 (2.6.5-3780M)
0.000000 send_to_all: SETINFO driver.parameter.port "auto"
0.000000 send_to_all: SETINFO driver.parameter.subdriver "krauler"
0.000000 send_to_all: SETINFO driver.parameter.protocol "megatec"
0.000000 send_to_all: SETINFO driver.parameter.langid_fix "0x409"
0.000000 s...
2013 Jun 26
0
smsbrasil-0.0.2 driver
...munication is lost.
- upsc sms always returns "Error: Data stale"
3096.067419 smsBR_RecAnswer: Started
3098.069531 smsBR_RecAnswer: Exiting by timeout (2 seconds)
3098.069592 Communications with UPS lost: upsdrv_updateinfo: UPS at port /dev/ttyUSB0 is returning by timeout...
3098.069617 send_to_all: DATASTALE
3098.069699 send_to_one: PONG
3101.070466 smsBR_RecAnswer: Started
3103.072605 smsBR_RecAnswer: Exiting by timeout (2 seconds)
3103.072686 Communications with UPS lost: upsdrv_updateinfo: UPS at port /dev/ttyUSB0 is returning by timeout...
3106.073475 smsBR_RecAnswer: Started
3108.075605...
2012 Dec 25
1
Blazer_usb Permissions problem: Input/output error
...read: (225.4 225.4 225.4 020 49.8 13.6 25.0 00001001
2517.292407 send: Unknown error
2517.292518 Permissions problem: Input/output error
# /usr/local/libexec/nut/blazer_usb -DDDDD -a eaton -u root
...
1451.821772 read: (221.5 221.0 221.0 019 49.8 13.6 25.0 00001001
1451.821797 send_to_all: SETINFO input.voltage "221.5"
1451.821805 send_to_all: SETINFO input.voltage.fault "221.0"
1451.821813 send_to_all: SETINFO ups.load "19"
1453.573762 send: Q1
1453.837774 read: (217.1 217.1 217.6 020 49.8 13.6 25.0 00001001
1453.837800 send_to_all:...
2013 Jun 26
3
smsbrasil-0.0.2 driver
Hello again!
Sorry for not being able to test this before.
Ulisses, please apply the patch to fix typo in my e-mail address.
I've compiled it against nut-2.6.5 about 10 hours ago. It was everything
fine until now. I'm seeing CHRG but the ups led wasn't blinking at all.
Vendor software was strangely showing charging also. I am assuming this is
expected behavior.
I've set the
2011 Sep 28
0
[BUG] nut 2.4.3+: UPS EP-1K: Firmware fault: USB-Interface crashes with nut.org monitoring if driver polling time <15 sec
...Art-Nr. 8296861, 70539, 14Z00000, 35-0200116-01G
@nut-users
http://www.networkupstools.org/ 2.4.3 debian stable, 2.6.2 upstream, linux 2.6.38-debian-bpo
# /usr/local/src/nut-2.6.2/drivers/blazer_usb -u root -DDDDD -a ups
Network UPS Tools - Megatec/Q1 protocol USB driver 0.03 (2.6.2)
0.000000 send_to_all: SETINFO driver.parameter.port "auto"
0.000080 send_to_all: SETINFO driver.parameter.chargetime "8"
0.000104 send_to_all: SETINFO driver.parameter.runtimecal "1200,100,3200,50"
0.000381 debug level is '5'
0.081525 Checking device (0D8C/0006) (00...
2014 Nov 05
1
blazer_usb disconnects
...commands
and then terminates with a "Got disconnected by another driver" message.
Any suggestions?
Example output from blazer_usb with loads of debug:
# /lib/nut/blazer_usb -DDDDDDDDDDDDDDDDDDDDDD -a nasups
Network UPS Tools - Megatec/Q1 protocol USB driver 0.10 (2.7.1)
0.000000 send_to_all: SETINFO driver.parameter.port "auto"
0.000118 send_to_all: SETINFO driver.parameter.vendorid "0665"
0.000175 send_to_all: SETINFO driver.parameter.productid "5161"
0.000248 debug level is '22'
(...snipped lines with incorrect devices..)
0....
2017 Jun 09
2
Help with Elite 800VA usb UPS
...FFFF/0000) (004/004)
0.561393 - VendorID: ffff
0.561428 - ProductID: 0000
0.561438 - Manufacturer:
0.561443 - Product: 010937
0.561457 - Serial Number:
0.561461 - Bus: 004
0.561466 Trying to match device
0.561473 Device matches
0.565355 send_to_all: SETINFO ups.vendorid "ffff"
0.565815 send_to_all: SETINFO ups.productid "0000"
0.566137 send: QGS
0.566421 read: QGS
0.566708 qx_process_answer: short reply (input.voltage)
0.567007 send: QGS
0.567377 read: QGS
0.567668 qx_proces...
2017 Jun 10
2
Help with Elite 800VA usb UPS
...FFFF/0000) (004/004)
0.560313 - VendorID: ffff
0.560574 - ProductID: 0000
0.560700 - Manufacturer:
0.560833 - Product: 010937
0.560958 - Serial Number:
0.561081 - Bus: 004
0.561205 Trying to match device
0.561332 Device matches
0.793308 send_to_all: SETINFO ups.vendorid "ffff"
0.793568 send_to_all: SETINFO ups.productid "0000"
0.793711 send_to_all: SETINFO device.type "ups"
0.793897 send_to_all: SETINFO driver.version "2.7.2"
0.794035 send_to_all: SETINFO driver.version.inter...
2016 Jan 18
4
NUT support for CyberPower PR1500LCDRTXL2Ua
Hey all,
I ended up picking up the module listed in Subject line.
I switched over my config but apparently not all going smoothly.
My config is:
[office]
driver = powerpanel
port = /dev/ttyS0
desc = "Office UPS"
When I test the driver running power-panel as a test, I get:
> [root at cornelius init.d]# powerpanel -a office -D -D -D -D
>
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
...ot;
NOTIFYCMD /usr/local/ups/bin/notifyme
POLLFREQ 5
POLLFREQALERT 5
HOSTSYNC 15
DEADTIME 15
POWERDOWNFLAG /etc/killpower
RBWARNTIME 43200
NOCOMMWARNTIME 300
FINALDELAY 5
/lib64/nut/blazer_ser -DDDDD -a munja -i 10
Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.6.0)
0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0"
0.000051 debug level is '5'
0.100836 send_to_all: SETINFO device.type "ups"
0.100860 send_to_all: SETINFO driver.version "2.6.0"
0.100870 send_to_all: SETINFO driver.version.internal "...
2009 Sep 19
1
Powercom 600AP USB support
...ed, so it's a start) (this could be the
general usb driver?)
* powercom - here is the output of the driver (supposed to be able to
communicate if cypress_m8 is present)
# ./powercom -DDDDD -a my -u root -x type=BNT
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.1-1993)
0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0"
0.000159 send_to_all: SETINFO driver.parameter.type "BNT"
0.000265 debug level is '5'
0.001334 Flow control disable
0.001544 Num of bytes requested for reading from UPS: 16
3.004656 data receiving error (0 instead of 16 by...
2016 Feb 17
1
Blazer_usb driver almost supports Centralion Titan Elite, but not quite
...I tried all the available protocols and subdrivers, and this combination
seems to be the one that gets more values.
Here's the driver's debuging output:
# /lib/nut/blazer_usb -u nut -DDDDDDDDD -a energit
Network UPS Tools - Megatec/Q1 protocol USB driver 0.12 (2.7.3.1)
0.000000 send_to_all: SETINFO driver.parameter.port "auto"
0.000077 send_to_all: SETINFO driver.parameter.vendorid "06da"
0.000100 send_to_all: SETINFO driver.parameter.productid "0201"
0.000118 send_to_all: SETINFO driver.parameter.subdriver "phoenix"
0.0...
2009 Mar 17
2
blazer_usb - short reply
...duct: USB UPS
- Serial Number: unknown
- Bus: 002
Trying to match device
Device matches
failed to claim USB device: could not claim interface 0: Device or
resource busy detached kernel driver from USB device...
Trying megatec protocol...
send: Q1
read: (218.7 218.7 218.7 020 50.0 0110 54.8 00001000
send_to_all: SETINFO input.voltage "218.7"
send_to_all: SETINFO input.voltage.fault "218.7"
send_to_all: SETINFO output.voltage "218.7"
send_to_all: SETINFO ups.load "20"
send_to_all: SETINFO input.frequency "50.0"
send_to_all: SETINFO battery.voltage "110...
2011 May 01
2
nut problem on boot/restart
...Communications with UPS soyntec at localhost lost
my setup:
Ubuntu 11.04 64bitNUT v2.6 deb from ubuntuUPS Soyntec Sekury C 800 USBcore i5, SSD corsair, 8GB ram, msi p67a-gd65
sudo /lib/nut/blazer_usb -DDDDD -a soyntec output?
Network UPS Tools - Megatec/Q1 protocol USB driver 0.03 (2.6.0)? 0.000000 send_to_all: SETINFO driver.parameter.port "auto"? ?0.000056 debug level is '5'? ?0.132441 Checking device (1D6B/0003) (004/001)? ?0.132483 - VendorID: 1d6b? ?0.132490 - ProductID: 0003? ?0.132495 - Manufacturer: unknown? ?0.132501 - Product: unknown? ?0.132506 - Serial Number: unknown? ?0.13...
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
...ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTi
meoutMultiplier -1
0.109369 vmin_ 1, vtime_ 0
0.109369 action 0
0.109369 vtime 0, vmin -1
0.109369 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTi
meoutMultiplier -1
0.218737 send_to_all: SETINFO device.type "ups"
0.218737 send_to_all: SETINFO driver.version "2.6.5-3780M"
0.218737 send_to_all: SETINFO driver.version.internal "1.55"
0.218737 send_to_all: SETINFO driver.name "blazer_ser"
0.218737 Trying megatec p...
2015 Mar 06
0
nutdrv_atcl_usb
...g to match device
0.398516 Device matches
0.398548 failed to claim USB device: could not claim interface 0:
Device or resource busy
0.398585 detached kernel driver from USB device...
0.398627 nut_usb_set_altinterface: skipped usb_set_altinterface(udev, 0)
0.398652 send_to_all: SETINFO ups.vendorid "0001"
0.398667 send_to_all: SETINFO ups.productid "0000"
0.398711 command: (8 bytes) => 80 06 04 03 51 47 53 00
0.403387 send: QGS
1.406382 read: could not claim interface 0: Device or resource busy
(-110)
1.406443 qx_...
2014 Jun 26
1
The dreaded Tripp Lite SMART500RT1U and NUT
...- Manufacturer: TRIPP LITE
0.017984 - Product: TRIPP LITE SMART500RT1U
0.019899 - Serial Number: unknown
0.020123 - Bus: 001
0.020785 Trying to match device
0.020974 Device matches
0.022584 Detected a UPS: TRIPP LITE/TRIPP LITE SMART500RT1U
0.022884 send_to_all: SETINFO ups.vendorid "09ae"
0.023091 send_to_all: SETINFO ups.productid "0001"
0.024146 send_to_all: SETINFO device.type "ups"
0.024961 send_to_all: SETINFO driver.version "2.6.4"
0.025174 send_to_all: SETINFO driver.version.inter...
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
...mbattvolt 41.1 since that seemed to be similar also to the Best
610-1000. As for battvoltmult, I must say I also experimented here.
The bestups driver seems to run ok:
C:\PROGRA~1\NUT\bin>bestups.exe -DDDDDDD -a ups1
Network UPS Tools - Best UPS driver 1.06 (2.6.3-3534:3545M)
0.000000 send_to_all: SETINFO driver.parameter.port "com1"
0.000000 send_to_all: SETINFO driver.parameter.id
"610,1000,230,230,10.0,36.0"
0.000000 send_to_all: SETINFO driver.parameter.nombattvolt "41.1"
0.015625 send_to_all: SETINFO driver.parameter.battvoltmult &...