search for: addcmd

Displaying 20 results from an estimated 36 matches for "addcmd".

2011 May 01
2
nut problem on boot/restart
...Vendor information read 3 failed? ?3.760056 Vendor information unavailable? ?3.760063 Battery runtime will not be calculated (runtimecal not set)? ?3.760076 send_to_all: SETINFO ups.delay.start "180"? ?3.760085 send_to_all: SETINFO ups.delay.shutdown "30"? ?3.760092 send_to_all: ADDCMD beeper.toggle? ?3.760098 send_to_all: ADDCMD load.off? ?3.760104 send_to_all: ADDCMD load.on? ?3.760110 send_to_all: ADDCMD shutdown.return? ?3.760116 send_to_all: ADDCMD shutdown.stayoff? ?3.760123 send_to_all: ADDCMD shutdown.stop? ?3.760129 send_to_all: ADDCMD test.battery.start? ?3.760135 send_...
2011 Mar 26
1
Help with Aiptek PowerWalker VFI 1000 LCD and Konig CMP1200
...0.876699 Vendor information read in 1 tries 0.876744 Battery runtime will not be calculated (runtimecal not set) 0.876766 send_to_all: SETINFO ups.delay.start "180" 0.876787 send_to_all: SETINFO ups.delay.shutdown "30" 0.876806 send_to_all: ADDCMD beeper.toggle 0.876826 send_to_all: ADDCMD load.off 0.876872 send_to_all: ADDCMD load.on 0.876893 send_to_all: ADDCMD shutdown.return 0.876912 send_to_all: ADDCMD shutdown.stayoff 0.876932 send_to_all: ADDCMD shutdown.stop 0.876952 send_to_all: ADDCMD...
2018 Feb 04
0
No answer from upsrw <ups name> command
...TFLAGS ups.delay.start RW > SETINFO ups.load "3" > SETINFO ups.productid "0003" > SETINFO ups.status "OL" > SETINFO ups.temperature "25.0" > SETINFO ups.type "offline / line interactive" > SETINFO ups.vendorid "06da" > ADDCMD beeper.toggle > ADDCMD load.off > ADDCMD load.on > ADDCMD shutdown.return > ADDCMD shutdown.stayoff > ADDCMD shutdown.stop > ADDCMD test.battery.start > ADDCMD test.battery.start.deep > ADDCMD test.battery.start.quick > ADDCMD test.battery.stop > DATAOK > DUMPDONE &...
2014 Nov 05
1
blazer_usb disconnects
...'guestimation' (low: 10.400000, high: 13.000000)! 1.076242 Battery runtime will not be calculated (runtimecal not set) 1.076303 send_to_all: SETINFO ups.delay.start "180" 1.076350 send_to_all: SETINFO ups.delay.shutdown "30" 1.076396 send_to_all: ADDCMD beeper.toggle 1.076450 send_to_all: ADDCMD load.off 1.076494 send_to_all: ADDCMD load.on 1.076537 send_to_all: ADDCMD shutdown.return 1.076580 send_to_all: ADDCMD shutdown.stayoff 1.076625 send_to_all: ADDCMD shutdown.stop 1.076668 send_to_all: ADDCMD test.batter...
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
...ot; 0.634686 Vendor information read in 1 tries 0.634693 Battery runtime will not be calculated (runtimecal not set) 0.634702 send_to_all: SETINFO ups.delay.start "180" 0.634711 send_to_all: SETINFO ups.delay.shutdown "30" 0.634719 send_to_all: ADDCMD beeper.toggle 0.634726 send_to_all: ADDCMD load.off 0.634733 send_to_all: ADDCMD load.on 0.634740 send_to_all: ADDCMD shutdown.return 0.634748 send_to_all: ADDCMD shutdown.stayoff 0.634755 send_to_all: ADDCMD shutdown.stop 0.634763 send_to_all: ADDCMD test....
2018 Jan 07
2
No answer from upsrw <ups name> command
2016 Jan 18
0
NUT support for CyberPower PR1500LCDRTXL2Ua
...0 30 > 1.458557 33 30 30 > 1.458596 send_to_all: SETINFO input.transfer.high "150" > 1.458626 send_to_all: SETINFO input.transfer.low "80" > 1.458655 send_to_all: SETINFO battery.charge.low "35" > 1.458680 send_to_all: ADDCMD test.battery.start.quick > 1.458705 send_to_all: ADDCMD test.battery.stop > 1.458730 send_to_all: ADDCMD beeper.enable > 1.458754 send_to_all: ADDCMD beeper.disable > 1.458778 send_to_all: ADDCMD beeper.on > 1.458802 send_to_all: ADDCMD beeper.off &...
2009 Mar 17
2
blazer_usb - short reply
...ppropriate HID device found blazer_vendor: short reply Vendor information read 3 failed Vendor information unavailable Battery runtime will not be calculated (runtimecal not set) send_to_all: SETINFO ups.delay.start "180" send_to_all: SETINFO ups.delay.shutdown "30" send_to_all: ADDCMD beeper.toggle send_to_all: ADDCMD load.off send_to_all: ADDCMD load.on send_to_all: ADDCMD shutdown.return send_to_all: ADDCMD shutdown.stayoff send_to_all: ADDCMD shutdown.stop send_to_all: ADDCMD test.battery.start send_to_all: ADDCMD test.battery.start.deep send_to_all: ADDCMD test.battery.start...
2011 Sep 28
0
[BUG] nut 2.4.3+: UPS EP-1K: Firmware fault: USB-Interface crashes with nut.org monitoring if driver polling time <15 sec
...ry runtime estimate : 1128.0 0.950533 battery charge time : 8 0.950545 No idle load specified, using built in default [10.0 %] 0.950562 send_to_all: SETINFO ups.delay.start "180" 0.950576 send_to_all: SETINFO ups.delay.shutdown "30" 0.950590 send_to_all: ADDCMD beeper.toggle 0.950602 send_to_all: ADDCMD load.off 0.950614 send_to_all: ADDCMD load.on 0.950627 send_to_all: ADDCMD shutdown.return 0.950641 send_to_all: ADDCMD shutdown.stayoff 0.950654 send_to_all: ADDCMD shutdown.stop 0.950668 send_to_all: ADDCMD test.battery.start...
2016 Feb 17
1
Blazer_usb driver almost supports Centralion Titan Elite, but not quite
...9;guestimation' (low: -0.866667, high: -1.083333)! 1.533339 Battery runtime will not be calculated (runtimecal not set) 1.533354 send_to_all: SETINFO ups.delay.start "180" 1.533368 send_to_all: SETINFO ups.delay.shutdown "30" 1.533381 send_to_all: ADDCMD beeper.toggle 1.533394 send_to_all: ADDCMD load.off 1.533406 send_to_all: ADDCMD load.on 1.533418 send_to_all: ADDCMD shutdown.return 1.533431 send_to_all: ADDCMD shutdown.stayoff 1.533443 send_to_all: ADDCMD shutdown.stop 1.533476 send_to_all: ADDCMD test....
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
...e specified, using built in default [43200 seconds] 4.093514 No idle load specified, using built in default [10.0 %] 4.093514 send_to_all: SETINFO ups.delay.start "180" 4.093514 send_to_all: SETINFO ups.delay.shutdown "240" 4.093514 send_to_all: ADDCMD beeper.toggle 4.093514 send_to_all: ADDCMD load.off 4.093514 send_to_all: ADDCMD load.on 4.093514 send_to_all: ADDCMD shutdown.return 4.093514 send_to_all: ADDCMD shutdown.stayoff 4.093514 send_to_all: ADDCMD shutdown.stop 4.093514 send_to_all: ADDCMD...
2013 Sep 16
2
Zigor Ebro 650 compatibility - revisited (on Windows, at least)
...625000 Using 'guestimation' (low: 10.400000, high: 13.000000)! 0.625000 Battery runtime will not be calculated (runtimecal not set) 0.625000 send_to_all: SETINFO ups.delay.start "180" 0.625000 send_to_all: SETINFO ups.delay.shutdown "30" 0.625000 send_to_all: ADDCMD beeper.toggle 0.625000 send_to_all: ADDCMD load.off 0.625000 send_to_all: ADDCMD load.on 0.625000 send_to_all: ADDCMD shutdown.return 0.625000 send_to_all: ADDCMD shutdown.stayoff 0.625000 send_to_all: ADDCMD shutdown.stop 0.625000 send_to_all: ADDCMD test.battery.start 0.62500...
2016 Jan 18
4
NUT support for CyberPower PR1500LCDRTXL2Ua
Hey all, I ended up picking up the module listed in Subject line. I switched over my config but apparently not all going smoothly. My config is: [office] driver = powerpanel port = /dev/ttyS0 desc = "Office UPS" When I test the driver running power-panel as a test, I get: > [root at cornelius init.d]# powerpanel -a office -D -D -D -D >
2009 Sep 19
1
Powercom 600AP USB support
...r "PowerCom" 3.004965 send_to_all: SETINFO ups.model "Unknown" 3.005057 send_to_all: SETINFO ups.serial "Unknown" 3.005148 send_to_all: SETINFO ups.model.type "BNT" 3.005250 send_to_all: SETINFO input.voltage.nominal "230" 3.005339 send_to_all: ADDCMD test.battery.start 3.005427 send_to_all: ADDCMD shutdown.return 3.005550 send_to_all: ADDCMD shutdown.stayoff 3.005727 Num of bytes requested for reading from UPS: 16 6.008828 data receiving error (0 instead of 16 bytes) 6.009091 dstate_init: sock /var/state/ups/powercom-my open on fd 5 6.009...
2015 Mar 06
0
nutdrv_atcl_usb
...6 32 2e 30 20.419387 read [ 32]: (8 bytes) => 20 20 20 20 20 20 0d 00 20.419412 read: # 2000VA V2.0 20.419541 ups_infoval_set: non significant value [device.mfr] 20.419572 send_to_all: SETINFO device.model "2000VA" 20.419591 send_to_all: ADDCMD beeper.toggle 20.419607 send_to_all: ADDCMD load.off 20.419633 send_to_all: ADDCMD load.on 20.419649 send_to_all: ADDCMD shutdown.return 20.419664 send_to_all: ADDCMD shutdown.stayoff 20.419678 send_to_all: ADDCMD shutdown.stop 20.419693 send_to_all: ADDCMD test....
2017 Jun 09
2
Help with Elite 800VA usb UPS
Use the name from ups.conf in front of "@localhost". ?The re?sult is quite different ;) root at artu:~# upsc Elit at artu Init SSL without certificate database Error: Driver not connected > What if you try nutdrv_qx without specifying megatec? (It should > autodetect.) > ?Here is the result: ? root at artu:~# upsdrvctl start Network UPS Tools - UPS driver controller
2017 Jun 10
2
Help with Elite 800VA usb UPS
...9;guestimation' (low: -0.866667, high: -1.083333)! 1.982878 Battery runtime will not be calculated (runtimecal not set) 1.983106 send_to_all: SETINFO ups.delay.start "180" 1.983331 send_to_all: SETINFO ups.delay.shutdown "30" 1.983551 send_to_all: ADDCMD beeper.toggle 1.983770 send_to_all: ADDCMD load.off 1.983986 send_to_all: ADDCMD load.on 1.984207 send_to_all: ADDCMD shutdown.return 1.984508 send_to_all: ADDCMD shutdown.stayoff 1.984750 send_to_all: ADDCMD shutdown.stop 1.984862 send_to_all: ADDCMD test....
2015 Mar 05
5
nutdrv_atcl_usb
On Mar 5, 2015, at 2:34 AM, Jakub <jakub.scepka at gmail.com> wrote: > Come on, it started to be interesting! Do you have one of these UPSes? If so, here was Dan's email about a branch to test: > If you still can't get it to work with nutdrv_atcl_usb, another > approach could be worth considering. > > Since this UPS seems to be supported by UPSmart2000I, it could
2011 May 09
0
PowerCom BNT2000AT ups on nut 2.6.0
...send_to_all: SETINFO ups.model "BNT2000APT" 0.147622 send_to_all: SETINFO ups.serial "2233445566" 0.147649 send_to_all: SETINFO ups.model.type "BNT" 0.147675 send_to_all: SETINFO input.voltage.nominal "230" 0.147699 send_to_all: ADDCMD test.battery.start 0.147722 send_to_all: ADDCMD shutdown.return 0.147746 send_to_all: ADDCMD shutdown.stayoff 0.147833 Num of bytes requested for reading from UPS: 16 0.293224 Num of bytes received from UPS: 16 I did run an strace and saw this! Starting at sending the s...
2010 Oct 03
1
You lost support of Belkin Universal UPS F6C1100-UNV
...l "24.0" send_to_all: SETINFO input.voltage.nominal "120.0" send_to_all: SETINFO input.frequency.nominal "60.0" 24.0V battery, interval [19.4V, 27.4V]. send_to_all: SETINFO ups.delay.start "2" send_to_all: SETINFO ups.delay.shutdown "0" send_to_all: ADDCMD test.battery.start.deep send_to_all: ADDCMD test.battery.start send_to_all: ADDCMD test.battery.stop send_to_all: ADDCMD shutdown.return send_to_all: ADDCMD shutdown.stayoff send_to_all: ADDCMD shutdown.stop send_to_all: ADDCMD load.on send_to_all: ADDCMD load.off send_to_all: ADDCMD reset.input.mi...