More detected parameters (attached), this time measurements for all 3 phases. I include only new discovered readings. Multipliers are wrong right now and need to be defined, and some commands are probably invalid/wrong, but most seem ok. I hope I find the time to implement those on the driver. What I'm missing is a way to discern between 1phase & 3phase (output) upses. output + read commands attached. Also. here are some untested ups commands (decimal, not yet tested, seem dangerous) for the brave, not sure if relevant to nut: ALARM_SILENCE, 1,156,2,1,1 BATTERY_TEST, 1,156,2,1,2 CANCEL, 1,156,2,1,3 OUTPUT_ON_DELAY, 1,156,2,1,4 OUTPUT_OFF_DELAY, 1,156,2,1,5 OUTPUT_OFF_MODE, 1,156,2,1,6 OUTPUT_OFF, 1,156,2,1,8 OUTPUT_ON, 1,156,2,1,9 XFER_TO_BYPASS, 1,156,2,1,10 XFER_TO_INVERTER, 1,156,2,1,11 SELF_TEST, 1,156,2,1,12 FRONT_PANEL_TEST, 1,156,2,1,13 RESET_COUNTERS, 1,156,2,1,14 RESET_SETTINGS, 1,156,2,1,15 -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20100411/ea9300af/attachment.htm> -------------- next part -------------- A non-text attachment was scrubbed... Name: dbg-out.zip Type: application/zip Size: 6470 bytes Desc: not available URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20100411/ea9300af/attachment.zip>