Displaying 20 results from an estimated 900 matches similar to: "Channel Bank Woes..."
2004 Jul 31
0
Trunk doesn't work Adit 600/T100P
Hi !
I am connecting to Adit 600 thru a T100P card
I have configured 1-16 FXS channels and 17-24 FXO.
Everything looks fine on Asterisk side I get a tone
on all FXS channels, but when I try to dialout thru
one of the FXO channels 17-24 it doesn't connect to
the POTS line and echoes back my voice.
I use fxsls and fxols for the T1 channels and ls on
Adit side. Whats wrong here ?
here is my Adit
2005 Oct 02
1
Adit 600 FXO card sound quality
I have an adit 600 with one fxo card connected to a Digium single span T1 card.
CallerID, disconnect supervision work perfect, however the users
complain that they have some sound quality issues, after testing it I
realized that whenever one is in a phone call they get like silence
between the sounds coming from the other party, almost like a cell
phone, in other words if there is no sound coming
2004 Apr 15
2
TE405P + Adit 600 and FXO module - should this work?
Folks,
I'm experimenting with bringing multiple (8) analog lines from our local
telco into a Carrier Access ADIT 600 channel bank with an FXO module, then
having this talk to Asterisk via the T1 TDM controller on the ADIT and a
TE405P card.
I don't know if this will work well (ie: give me decent echo cancellation,
call disconnect supervision, caller ID etc) but I haven't had much
2004 Nov 29
1
Cisco gateway help needed
HI,
I have been pulling my hair out trying to get a Cisco MC3810 to interface my
Asterisk box with a T1.
I am able to make outgoing calls but incoing calls never reach my Asterisk
box. The cisco give a fast busy when I try to call one of the DID's. When
playing around with the dial-peers I can get the cisco to pick up the call,
but then it forwards the call back to the ANI that is dialing.
2004 Jun 28
2
Adit 600 - Getting Dial Tone
Hello, I have an Adit 600 (3 FXS cards) hooked up to a digium T1 card in my
asterisk box. I 'connected' the slots to the a:1 T1 interfaces via the
command line. The slots (3 fxs) are configured with 'ls' signaling. I
configured the T1 card with the same line settings as the T1 interfaces on
the adit and I get green lights on both the T1 card and the T1 interface on
the adit (so
2005 Jan 04
0
Cisco 7200 One-Way Audio
Hi,
I am experiencing one-way audio from:
SIP Device ----> Asterisk -----> Cisco 7200
The Cisco 7200 has a VXE+ card that will allow you to do SIP. I can pass
audio from SIP Device to Asterisk through the Cisco 7200 to the other end,
but the Cisco 7200 does not return any audio back to the SIP Device or
Asterisk, it seems. I have tried upgrading to 12.3T IOS version, but no
2005 Feb 16
1
Zaptel DACS and FDL
I have the following configuration:
CLEC -> T-1 -> Asterisk -> Adtran Channel Bank -> (analog) -> Nortel
Don't complain that it's ugly. I've already done plenty of that.
The CLEC manages their Adtran remotely and needs to be able to
continue to do so. I assume they use FDL to do the management. We
are using the Zaptel DACS/DACSRBS to cross connect some of the
2004 Jul 25
3
FXS vs. FXO
Hello,
I've recently purchased Adit 600 with 3FXS and 1FXO to be connected to
my * server via T100P card. This is the output of "status equipment"
command in the Adit600:
For some reason the FXO card is seen as FXS, why? Is it ok? On the card
it is written "FXO".
Regards,
Shlomi Bachar
-------------- next part --------------
An HTML attachment was
2011 Jul 12
1
suggestions regarding reading in a messy file
I have a file in stata format, which I have read in, and I am trying
to create a text file. I have exported the data using various
delimiters, but I'm unable to read it back in. I originally read in
the file with:
library(foreign)
myData <- read.dta("mydata.dta")
I then exported it with write.table using comma, tab, and exclamation
marks as a delimiter.
When I was unable to
2007 Jul 01
2
the-asterisk-book.com online (unstable version)
Hi,
this is to inform everybody that the translation of my new book
(unstable version) is online at http://www.the-asterisk-book.com
The book is a GNU FDL project. So everybody who wants to participate
is welcome to do so. Also, everybody who needs material for his own
work, feel free to take it as long as the new material will become
GNU FDL too.
I am glad that Stephen Bosch (who you
2004 Dec 11
0
Security exploit downloaded with FLAC?
On Sat, Dec 11, 2004 at 07:37:40PM -0500, Helen Glazer wrote:
> As is my routine every couple of weeks, I ran Pest Patrol anti-spyware
> software, and was disturbed to find it came back saying that the file
> FLAC/COPYING.FDL was a security exploit known as "Virus Tutorial" or
> VTool/jul2. This has left me wondering if FLAC is to be trusted.
Well, since the file in
2004 Feb 02
0
Carrier Access Access Bank 1, incomming calls only echo problems, and Adit 600
I am a little confused about the FXO ports on the Carrier Accesss Bank
1. The wiki, and people on the mailing list have stated that they do not
have impedance matching, but Carrier Access states in their
documentation that they do have impednace matching. Did Carrier Access
make a typo, or does it depend on the version of the FXO card?
I current have a CAC AB1, and I am having echo problems
2004 Nov 29
1
[Fwd: Re: Adit 600 channel bank in UK setting]
Jon,
I actually had some more discussions with Tim on this issue, and it seems that the channel bank
would still be a good option to choose for internal purposes. I would not see any other solution
than a channel bank to connect many 2wire phones into one asterisk box. I had a talk today with
Carrier Access, and it seems that the adit would do us fine. The fxs cards of the adit 600 are
2004 Nov 18
1
[Fwd: Re: Adit 600 channel bank in UK setting]
Peter
- 40 phones and only 3 PSTN trunks?. I would recommend at least 2 BRIs
for this. If you have ISDN you can also get DDI to the extensions.I
would strongly recommend abandoning the analogue PSTN lines and using
ISDN. The setup pain you will go through will be significantly less,
combined with better audio, more features (like DDI numbers!) and much
more robust connections.
You should look
2004 Dec 11
2
Security exploit downloaded with FLAC?
As is my routine every couple of weeks, I ran Pest Patrol anti-spyware
software, and was disturbed to find it came back saying that the file
FLAC/COPYING.FDL was a security exploit known as "Virus Tutorial" or
VTool/jul2. This has left me wondering if FLAC is to be trusted. Here's
what PestPatrol's web site has to say about it:
Exploit: A way of breaking into a system. An
2007 Feb 13
4
Nortel 81C MSDL Trunking to Asterisk TE110P, Nortel Resetting PRI Channels
We are currently working to trunk from a Nortel 81C to an Asterisk
Server 1.4 running on Red Hat Linux. We have two PRI trunks which work
with the exception of the clock slips, which is causing the Nortel to
reset the PRIs once a hour. Thanks for any suggestions.
81C MSDL Asterisk Digium
TE110P
REQ prt
TYPE adan dch 10
2009 Jul 01
1
xyplot question
I have a data set like this
ID=c("A","A","A","A","A","A","A","B","B","B","B","B","B","B")
s=c(1.1,2.2,1.3,1.1,3.1,4.1,4.2,1.1,2.2,1.3,1.1,3.1,4.1,4.2)
d=c(1,2,3,4,5,6,7,1,2,3,4,5,6,7)
t=c(-3,-2,-1,0,1,2,3,-3,-2,-1,0,1,2,3)
2019 Apr 10
1
[PATCH v2 1/3] drm: switch drm_fb_memcpy_dstclip to accept __iomem dst
Not all archs have the __io_virt() macro, so cirrus can't simply convert
pointers that way. The drm format helpers have to use memcpy_toio()
instead.
This patch makes drm_fb_memcpy_dstclip() accept a __iomem dst pointer
and use memcpy_toio() instead of memcpy(). With that separating out the
memcpy loop into the drm_fb_memcpy_lines() helper isn't useful any more,
so move the code back
2009 Jul 02
1
another xyplot question
I have a data set like this
ID=c("A","A","A","A","A","A","A","B","B","B","B","B","B","B")
s=c(1.1,2.2,1.3,1.1,3.1,4.1,4.2,1.1,2.2,1.3,1.1,3.1,4.1,4.2)
d=c(1,2,3,4,5,6,7,1,2,3,4,5,6,7)
t=c(-3,-1,0,1,2,3,4,-3,-2,-1,0,1,2,3)
2003 Jul 10
6
Channel Bank configuration
Hello,
I don't have any experience with channel banks and would appreciate any
feedback on my theory outlined below:
We have a single T1 entering the building with channels 1-12 being voice
lines and 13-24 being a 768k internet connection. This T1 terminates to
an Adit 600 (T1-1).
Here's what I know. Channels 11-12 go out the Adit 600's 25-pair
connector to a wiring block (and