Hi,
I'm sorry, it seems it does not work with the latest UPSMON windows
binary either. I'll request a replacement.
Best regards,
Peter Balogh
Balogh P?ter wrote:> Hi,
>
> I know it's been a topic many times here, but I've searched the
> archives, googled for days, and I simply don't believe, that there is
> still no solution to this.
> I'm using a PowerCom BNT-600AP ups with usb port.
>
> I've downloaded the latest version from svn, compiled it, and tried to
> use it:
> * megatec(_usb) - no luck, it did not find the UPS (I?ve read in this
> list, that this driver uses the same protocol)
> * usbhid-ups - no information about the battery, only basic
> information about the UPS (it's communicated, so it's a start)
(this
> could be the general usb driver?)
> * powercom - here is the output of the driver (supposed to be able to
> communicate if cypress_m8 is present)
>
> # ./powercom -DDDDD -a my -u root -x type=BNT
>
> Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.1-1993)
>
> 0.000000 send_to_all: SETINFO driver.parameter.port "/dev/ttyS0"
>
> 0.000159 send_to_all: SETINFO driver.parameter.type "BNT"
>
> 0.000265 debug level is '5'
>
> 0.001334 Flow control disable
>
> 0.001544 Num of bytes requested for reading from UPS: 16
>
> 3.004656 data receiving error (0 instead of 16 bytes)
>
> 3.004774 send_to_all: SETINFO device.type "ups"
>
> 3.004872 send_to_all: SETINFO ups.mfr "PowerCom"
>
> 3.004965 send_to_all: SETINFO ups.model "Unknown"
>
> 3.005057 send_to_all: SETINFO ups.serial "Unknown"
>
> 3.005148 send_to_all: SETINFO ups.model.type "BNT"
>
> 3.005250 send_to_all: SETINFO input.voltage.nominal "230"
>
> 3.005339 send_to_all: ADDCMD test.battery.start
>
> 3.005427 send_to_all: ADDCMD shutdown.return
>
> 3.005550 send_to_all: ADDCMD shutdown.stayoff
>
> 3.005727 Num of bytes requested for reading from UPS: 16
>
> 6.008828 data receiving error (0 instead of 16 bytes)
>
> 6.009091 dstate_init: sock /var/state/ups/powercom-my open on fd 5
>
> 6.009195 send_to_all: SETINFO driver.version "2.4.1-1993"
>
> 6.009289 send_to_all: SETINFO driver.version.internal "0.12"
>
> 6.009384 send_to_all: SETINFO driver.name "powercom"
>
> 6.009477 send_to_all: SETINFO driver.parameter.pollinterval "2"
>
> 6.009570 send_to_all: SETINFO device.mfr "PowerCom"
>
> 6.009662 send_to_all: SETINFO device.model "Unknown"
>
> 6.009753 send_to_all: SETINFO device.serial "Unknown"
>
> 6.009925 Num of bytes requested for reading from UPS: 16
>
> 9.013063 data receiving error (0 instead of 16 bytes)
>
> 9.013266 Num of bytes requested for reading from UPS: 16
>
> 12.016373 data receiving error (0 instead of 16 bytes)
>
> 12.016560 Num of bytes requested for reading from UPS: 16
>
> 15.019668 data receiving error (0 instead of 16 bytes)
>
> 15.019859 Num of bytes requested for reading from UPS: 16
>
> ^C 15.478328 data receiving error (-1 instead of 16 bytes)
>
> 17.021330 Signal 2: exiting
>
> #lsusb ?v
>
> Bus 003 Device 002: ID 0d9f:0002 Powercom Co., Ltd
>
> Device Descriptor:
>
> bLength 18
>
> bDescriptorType 1
>
> bcdUSB 1.00
>
> bDeviceClass 0 (Defined at Interface level)
>
> bDeviceSubClass 0
>
> bDeviceProtocol 0
>
> bMaxPacketSize0 8
>
> idVendor 0x0d9f Powercom Co., Ltd
>
> idProduct 0x0002
>
> bcdDevice 0.00
>
> iManufacturer 1 POWERCOM CO., LTD.
>
> iProduct 2 USB to Serial
>
> iSerial 0
>
> bNumConfigurations 1
>
> Best regards,
>
> Peter Balogh
>
>
> _______________________________________________
> Nut-upsdev mailing list
> Nut-upsdev at lists.alioth.debian.org
> http://lists.alioth.debian.org/mailman/listinfo/nut-upsdev