Displaying 20 results from an estimated 38 matches for "internalfailur".
Did you mean:
internalfailure
2007 Feb 26
1
Tripp Lite USB UPS
...06
Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0,
Size: 16, Value: 1789.000000
Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset:
0, Size: 16, Value: 1789.000000
Report[r]: (4 bytes) => 32 00 00 11
Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID:
0x32, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, ReportID:
0x32, Offset: 9, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x32,
Offset: 16, Size: 1, Value: 1.00...
2018 May 25
1
[HCL] IBM 1500VA/1000W Tower HV UPS supported by usbhid-ups
...BatterySystem.Charger.PresentStatus.ffff0079,
Type: Feature, ReportID: 0x27, Offset: 24, Size: 8, Value: 1
3.513827 Path: UPS.BatterySystem.Charger.PresentStatus.ffff0079,
Type: Input, ReportID: 0x27, Offset: 24, Size: 8, Value: 1
3.514036 Path:
UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Feature,
ReportID: 0x27, Offset: 32, Size: 8, Value: 0
3.514571 Path:
UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Input,
ReportID: 0x27, Offset: 32, Size: 8, Value: 0
3.514785 Path: UPS.BatterySystem.Charger.PresentStatus.Used, Type:
Feature, ReportID: 0x27,...
2008 Dec 31
2
Unknown product ID for Tripp-Lite UPS (SU1500RTXL2UA)
...tID: 0x3b, Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.CapacityGranularity2, Type: Feature, ReportID: 0x39, Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.Rechargeable, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID: 0x32, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, ReportID: 0x32, Offset: 9, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x32, Offset: 16, Size: 1, Value: 1.00000...
2008 Jan 02
2
[nut-commits] svn commit r1210 - in trunk: . drivers
On Jan 2, 2008 3:34 PM, Arjen de Korte <adkorte-guest at alioth.debian.org> wrote:
> Author: adkorte-guest
> Date: Wed Jan 2 20:34:26 2008
> New Revision: 1210
>
> Log:
> Parsing continues if the HID path for a report ends in 0x00000000 (these will not be made available). Commonly used as placeholders.
>
> It looks like (but correct me if I'm wrong) that reports
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
...120
0.025997 Path: UPS.PowerSummary.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0, Size: 16, Value: 0.001233
0.027006 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x11, Offset: 0, Size: 8, Value: 3
0.027995 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x32, Offset: 7, Size: 1, Value: 0
0.028034 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID: 0x32, Offset: 7, Size: 1, Value: 0
0.028059 Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Feature, ReportID: 0x32, Offset:...
2013 Aug 07
4
HP R1500 G3 problems
...lue: 20
0.465126 Path: UPS.PowerSummary.CapacityGranularity1, Type:
Feature, ReportID: 0x3b, Offset: 0, Size: 8, Value: 1
0.469121 Path: UPS.PowerSummary.Rechargeable, Type: Feature,
ReportID: 0x2c, Offset: 0, Size: 8, Value: 1
0.473114 Path: UPS.PowerSummary.PresentStatus.InternalFailure,
Type: Input, ReportID: 0x32, Offset: 0, Size: 1, Value: 0
0.473220 Path: UPS.PowerSummary.PresentStatus.ShutdownImminent,
Type: Input, ReportID: 0x32, Offset: 1, Size: 1, Value: 0
0.473305 Path: UPS.PowerSummary.PresentStatus.FullyDischarged,
Type: Input, ReportID: 0x32, Offset...
2012 Jul 18
1
Problem connecting to eaton ups. No matching HID UPS found. Driver failed to start(exit status=1)
...552376 Path: UPS.OutletSystem.Outlet.[3].PresentStatus.SwitchOn/Off, Type: Input, ReportID: 0x02, Offset: 24, Size: 8, Value: 1
4.552664 Path: UPS.OutletSystem.OutletSystemID, Type: Feature, ReportID: 0x0b, Offset: 56, Size: 8, Value: 1
4.552847 Path: UPS.PowerConverter.Inverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x03, Offset: 16, Size: 8, Value: 0
4.553038 Path: UPS.PowerConverter.Inverter.PresentStatus.InternalFailure, Type: Input, ReportID: 0x03, Offset: 16, Size: 8, Value: 0
4.599949 Path: UPS.PowerConverter.Output.HighVoltageTransfer, Type: Feature, ReportID: 0x13, Offs...
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
...8, Size: 8, Value: 1.000000
Path: UPS.BatterySystem.Charger.ChargerID, Type: Feature, ReportID: 0x20,
Offset: 16, Size: 8, Value: 1.000000
Path: UPS.BatterySystem.Charger.ChargerType, Type: Feature, ReportID: 0x26,
Offset: 0, Size: 8, Value: 0.000000
Path: UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Feature,
ReportID: 0x27, Offset: 8, Size: 8, Value: 0.000000
Path: UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Input,
ReportID: 0x27, Offset: 8, Size: 8, Value: 0.000000
Path: UPS.BatterySystem.Charger.PresentStatus.VoltageTooHigh, Type: Feature,
ReportID: 0x27, Offset...
2010 Feb 18
2
HP R1500 G2 UPS
...ID: 0x38, Offset: 0, Size: 8, Value: 20.000000
Path: UPS.PowerSummary.CapacityGranularity1, Type: Feature, ReportID: 0x3b, Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.Rechargeable, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID: 0x32, Offset: 0, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, ReportID: 0x32, Offset: 1, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.FullyDischarged, Type: Input, ReportID: 0x32, Offset: 2, Size: 1, Value: 0....
2014 Apr 05
0
I can't make changes to ups.delay.shutdown to stick
On Apr 5, 2014, at 7:18 AM, Mick wrote:
> $ upsrw -s "ups.delay.shutdown"="30" iDowell at localhost
> Username (suzy): admin
> Password:
> OK
This command is sending the value to the UPS (via the usbhid-ups driver).
> $ upsc iDowell at localhost ups.delay.shutdown
> 30
And this command ends up reading the value back from the UPS.
> However, following
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
...lue: 1
1.002960 Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type:
Input, ReportID: 0x02, Offset: 6, Size: 1, Value: 0
1.002977 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input,
ReportID: 0x02, Offset: 7, Size: 1, Value: 0
1.002992 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input,
ReportID: 0x02, Offset: 8, Size: 1, Value: 0
1.003007 Path: UPS.PowerSummary.PresentStatus.Undefined, Type: Input,
ReportID: 0x02, Offset: 9, Size: 7, Value: 0
1.003021 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature,
ReportID: 0x02, Offset: 0, Size: 1, Value:...
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
Hi All,
I'm using an iDowell UPS with the usbhid-ups driver:
$ upsc iDowell at localhost
battery.charge: 100
battery.charge.low: 15
battery.runtime: 650
battery.type: Pb acc
device.mfr: iDowell
device.model: iBox
device.serial: 00000001
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
2016 May 03
2
New UPS Support: Eaton 5S 1000
Oops... changing that to --with-user=nut solved one problem. I have the
driver, upsd and upsmon running now. Thank you!
Now I'm back to another issue, every 2 seconds I get in the logs:
May 3 13:45:23 myhost upsd[2587]: Connected to UPS [eaton]:
usbhid-ups-eaton
It seems happy to do this forever.
On Tue, May 3, 2016 at 8:17 AM, Charles Lepple <clepple at gmail.com> wrote:
> On
2016 May 04
2
New UPS Support: Eaton 5S 1000
...ath: UPS.PowerConverter.Input.[1].PresentStatus.WiringFault,
Type: Input, ReportID: 0x04, Offset: 32, Size: 8, Value: 0
5.304083 Path: UPS.PowerConverter.Input.[1].Voltage, Type: Feature,
ReportID: 0x0e, Offset: 16, Size: 16, Value: 121
5.304092 Path:
UPS.PowerConverter.Inverter.PresentStatus.InternalFailure, Type: Feature,
ReportID: 0x03, Offset: 16, Size: 8, Value: 0
5.304101 Path:
UPS.PowerConverter.Inverter.PresentStatus.InternalFailure, Type: Input,
ReportID: 0x03, Offset: 16, Size: 8, Value: 0
5.304121 Path: UPS.PowerConverter.Output.ActivePower, Type: Feature,
ReportID: 0x0e, Offset: 32,...
2016 Apr 16
2
IBM 5396-1Kx ups nearly recognised.
...7 bytes) => 27 01 00 00 01 00 01
3.478683 Path: UPS.BatterySystem.Charger.PresentStatus.ffff0079,
Type: Input, ReportID: 0x27, Offset: 24, Size: 8, Value: 1
3.478700 Report[buf]: (7 bytes) => 27 01 00 00 01 00 01
3.478736 Path:
UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Feature,
ReportID: 0x27, Offset: 32, Size: 8, Value: 0
3.478753 Report[buf]: (7 bytes) => 27 01 00 00 01 00 01
3.478770 Path:
UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Input,
ReportID: 0x27, Offset: 32, Size: 8, Value: 0
3.478787 Report[buf...
2015 Aug 15
2
Small patch to scale the values for TRIPP-LITE SMART*LCDT's
Hi,
I just decided to fix some scaling issues for my UPS (TRIPP-LITE
SMART1500LCDT). Apparently that issue existed for some time (and I knew
about it as well:-()
See http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 for a
thread.
My little patch is attached (against 2.7.3). It seems to be working
better for me but I don't have any other TRIPP-LITE's to test that I did
2015 Aug 15
2
Small patch to scale the values for TRIPP-LITE SMART*LCDT's
Hi,
I just decided to fix some scaling issues for my UPS (TRIPP-LITE
SMART1500LCDT). Apparently that issue existed for some time (and I knew
about it as well:-()
See http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 for a
thread.
My little patch is attached (against 2.7.3). It seems to be working
better for me but I don't have any other TRIPP-LITE's to test that I did
2012 Oct 22
1
Wrong parsing in gen-usbhid-subdriver ?
...: 16, Value: 0
0.336508 Path: UPS.PowerSummary.PresentStatus.Present, Type: Feature, ReportID: 0x40, Offset: 0, Size: 1, Value: 0
0.336522 Path: UPS.PowerSummary.PresentStatus.Good, Type: Feature, ReportID: 0x40, Offset: 1, Size: 1, Value: 0.01
0.336535 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x40, Offset: 2, Size: 1, Value: 0
0.336547 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x40, Offset: 3, Size: 1, Value: 0
0.336559 Path: UPS.PowerSummary.PresentStatus.OverCharged, Type: Feature, ReportID: 0x40, Offset: 4, Size: 1, Value...
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
...Path: UPS.BatterySystem.Charger.PresentStatus.Floating, Type: Feature, ReportID: 0x27, Offset: 8, Size: 8, Value: 1
5.103557 Path: UPS.BatterySystem.Charger.PresentStatus.Floating, Type: Input, ReportID: 0x27, Offset: 8, Size: 8, Value: 1
5.103569 Path: UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x27, Offset: 16, Size: 8, Value: 0
5.103579 Path: UPS.BatterySystem.Charger.PresentStatus.InternalFailure, Type: Input, ReportID: 0x27, Offset: 16, Size: 8, Value: 0
5.103589 Path: UPS.BatterySystem.Charger.PresentStatus.Used, Type: Feature, ReportID: 0x27, Offset:...
2020 Jun 28
0
AVR750U Low Power not Triggering Shutdown
...5997 Path: UPS.PowerSummary.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0, Size: 16, Value: 0.001233
> 0.027006 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x11, Offset: 0, Size: 8, Value: 3
> 0.027995 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x32, Offset: 7, Size: 1, Value: 0
> 0.028034 Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID: 0x32, Offset: 7, Size: 1, Value: 0
> 0.028059 Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Feature, ReportID: 0...