Hi,
I have a HP R1500 G2 UPS and want to get it working under Debian Lenny - as this
OS is not supported by HP I'm
trying to use nut for it - but I can't get it working.
Do I have any chance to get the UPS running with nut. I also tried different
drivers but had no luck either.
Or does anyone has experience with HP UPS under debian ?
Any help would be nice !
I tried
/lib/nut/usbhid-ups -DD -u root -x explore -x vendorid=3f0 -a HPR1500
And that gives me following output below
Thanks
Checking device (03F0/1FE0) (002/002)
- VendorID: 03f0
- ProductID: 1fe0
- Manufacturer: Hewlett-Packard
- Product: HP R1500 G2 UPS
- Serial Number: 3C88431991
- Bus: 002
Trying to match device
Device matches
HID descriptor length 924
Report Descriptor size = 924
Using subdriver: EXPLORE HID 0.1
Path: UPS.PowerSummary.iProduct, Type: Feature, ReportID: 0x28, Offset: 0, Size:
8, Value: 36.000000
Path: UPS.PowerSummary.iSerialNumber, Type: Feature, ReportID: 0x29, Offset: 0,
Size: 8, Value: 50.000000
Path: UPS.PowerSummary.iManufacturer, Type: Feature, ReportID: 0x2b, Offset: 0,
Size: 8, Value: 4.000000
Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0,
Size: 24, Value: 1476.000000
Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0,
Size: 24, Value: 1476.000000
Path: UPS.PowerSummary.Input.ConfigVoltage, Type: Feature, ReportID: 0x30,
Offset: 0, Size: 8, Value: 230.000000
Path: UPS.PowerSummary.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0,
Size: 16, Value: 228.000000
Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x11,
Offset: 0, Size: 8, Value: 2.000000
Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x2a, Offset:
0, Size: 8, Value: 40.000000
Path: UPS.PowerSummary.iOEMInformation, Type: Feature, ReportID: 0x62, Offset:
0, Size: 8, Value: 4.000000
Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x33, Offset: 0,
Size: 8, Value: 2.000000
Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x34, Offset:
0, Size: 8, Value: 95.000000
Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offset:
0, Size: 8, Value: 95.000000
Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x3a,
Offset: 0, Size: 8, Value: 20.000000
Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, ReportID: 0x37,
Offset: 0, Size: 8, Value: 100.000000
Path: UPS.PowerSummary.DesignCapacity, Type: Feature, ReportID: 0x36, Offset: 0,
Size: 8, Value: 100.000000
Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, ReportID: 0x38,
Offset: 0, Size: 8, Value: 20.000000
Path: UPS.PowerSummary.CapacityGranularity1, Type: Feature, ReportID: 0x3b,
Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.Rechargeable, Type: Feature, ReportID: 0x2c, Offset: 0,
Size: 8, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Input, ReportID:
0x32, Offset: 0, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, ReportID:
0x32, Offset: 1, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.FullyDischarged, Type: Input, ReportID:
0x32, Offset: 2, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x32,
Offset: 3, Size: 1, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Input,
ReportID: 0x32, Offset: 4, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.Charging, Type: Input, ReportID: 0x32,
Offset: 5, Size: 1, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Input, ReportID: 0x32,
Offset: 6, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID:
0x32, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.InternalFailure, Type: Feature, ReportID:
0x32, Offset: 0, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Feature, ReportID:
0x32, Offset: 1, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.FullyDischarged, Type: Feature, ReportID:
0x32, Offset: 2, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x32,
Offset: 3, Size: 1, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature,
ReportID: 0x32, Offset: 4, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x32,
Offset: 5, Size: 1, Value: 1.000000
Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x32,
Offset: 6, Size: 1, Value: 0.000000
Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Feature, ReportID:
0x32, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.ConfigVoltage, Type: Feature, ReportID: 0x04,
Offset: 0, Size: 8, Value: 36.000000
Path: UPS.BatterySystem.Battery.RunTimeToEmpty, Type: Input, ReportID: 0x6f,
Offset: 0, Size: 16, Value: 240000000.000000
Path: UPS.BatterySystem.Battery.RunTimeToEmpty, Type: Feature, ReportID: 0x6f,
Offset: 0, Size: 16, Value: 240000000.000000
Path: UPS.BatterySystem.Battery.Voltage, Type: Feature, ReportID: 0x20, Offset:
0, Size: 16, Value: 39.000000
Path: UPS.BatterySystem.Battery.PresentStatus.BelowRemainingCapacityLimit, Type:
Feature, ReportID: 0x23, Offset: 2, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.PresentStatus.FullyCharged, Type: Feature,
ReportID: 0x23, Offset: 3, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.PresentStatus.Charging, Type: Feature, ReportID:
0x23, Offset: 4, Size: 1, Value: 1.000000
Path: UPS.BatterySystem.Battery.PresentStatus.Discharging, Type: Feature,
ReportID: 0x23, Offset: 5, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.PresentStatus.FullyDischarged, Type: Feature,
ReportID: 0x23, Offset: 6, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.PresentStatus.NeedReplacement, Type: Feature,
ReportID: 0x23, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.BatterySystem.Battery.RemainingCapacity, Type: Feature, ReportID:
0x21, Offset: 0, Size: 8, Value: 95.000000
Path: UPS.BatterySystem.Test, Type: Feature, ReportID: 0x10, Offset: 0, Size: 8,
Value: 6.000000
Path: UPS.BatterySystem.Temperature, Type: Feature, ReportID: 0x1a, Offset: 0,
Size: 16, Value: 50.000000
Path: UPS.Flow.ConfigVoltage, Type: Feature, ReportID: 0x01, Offset: 0, Size: 8,
Value: 230.000000
Path: UPS.Flow.ConfigPercentLoad, Type: Feature, ReportID: 0x05, Offset: 0,
Size: 8, Value: 80.000000
Path: UPS.Flow.ConfigFrequency, Type: Feature, ReportID: 0x02, Offset: 0, Size:
8, Value: 50.000000
Path: UPS.Flow.ConfigApparentPower, Type: Feature, ReportID: 0x03, Offset: 0,
Size: 16, Value: 1500.000000
Path: UPS.PowerConverter.Input.Voltage, Type: Feature, ReportID: 0x18, Offset:
0, Size: 16, Value: 228.000000
Path: UPS.PowerConverter.Input.Frequency, Type: Feature, ReportID: 0x19, Offset:
0, Size: 16, Value: 50.300000
Path: UPS.PowerConverter.Output.Voltage, Type: Feature, ReportID: 0x1b, Offset:
0, Size: 16, Value: 228.000000
Path: UPS.PowerConverter.Output.ApparentPower, Type: Feature, ReportID: 0x07,
Offset: 0, Size: 16, Value: 439.000000
Path: UPS.PowerConverter.Output.Current, Type: Feature, ReportID: 0x08, Offset:
0, Size: 16, Value: 1.950000
Path: UPS.PowerConverter.Output.Frequency, Type: Feature, ReportID: 0x1c,
Offset: 0, Size: 16, Value: 50.300000
Path: UPS.PowerConverter.Output.LowVoltageTransfer, Type: Feature, ReportID:
0x06, Offset: 0, Size: 16, Value: 194.000000
Path: UPS.PowerConverter.Output.HighVoltageTransfer, Type: Feature, ReportID:
0x09, Offset: 0, Size: 16, Value: 266.000000
Path: UPS.PowerConverter.PresentStatus.VoltageOutOfRange, Type: Feature,
ReportID: 0x22, Offset: 0, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.Buck, Type: Feature, ReportID: 0x22,
Offset: 1, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.Boost, Type: Feature, ReportID: 0x22,
Offset: 2, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.Overload, Type: Feature, ReportID: 0x22,
Offset: 4, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.Used, Type: Feature, ReportID: 0x22,
Offset: 5, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.OverTemperature, Type: Feature, ReportID:
0x22, Offset: 6, Size: 1, Value: 0.000000
Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID:
0x22, Offset: 7, Size: 1, Value: 0.000000
Path: UPS.OutletSystem.Outlet.ActivePower, Type: Feature, ReportID: 0x54,
Offset: 0, Size: 16, Value: 413.000000
Path: UPS.OutletSystem.Outlet.OutletID, Type: Feature, ReportID: 0x6e, Offset:
0, Size: 8, Value: 0.000000
Path: UPS.OutletSystem.Outlet.DelayBeforeShutdown, Type: Feature, ReportID:
0x15, Offset: 0, Size: 16, Value: -1.000000
Path: UPS.OutletSystem.Outlet.DelayBeforeStartup, Type: Feature, ReportID: 0x61,
Offset: 0, Size: 16, Value: -1.000000
Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17,
Offset: 0, Size: 16, Value: -1.000000
Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e,
Offset: 0, Size: 8, Value: 41.000000
Path: UPS.ffff0010.[1].ffff007f, Type: Feature, ReportID: 0x0d, Offset: 0, Size:
8, Value: 6.000000
Path: UPS.ffff0010.[1].ffff007b, Type: Feature, ReportID: 0x6d, Offset: 0, Size:
8, Value: 2.000000
Path: UPS.ffff0010.[1].ffff007a, Type: Feature, ReportID: 0x70, Offset: 0, Size:
8, Value: 1.000000
Path: UPS.ffff0010.[1].ffff007e, Type: Feature, ReportID: 0x0e, Offset: 0, Size:
16, Value: 512.000000
Path: UPS.ffff0010.[1].ffff007c, Type: Feature, ReportID: 0x0f, Offset: 0, Size:
16, Value: 512.000000
Path: UPS.ffff0010.[1].ffff007d, Type: Feature, ReportID: 0x6c, Offset: 0, Size:
16, Value: 2560.000000
Path: UPS.ffff0010.[1].ffff0056, Type: Feature, ReportID: 0x71, Offset: 0, Size:
16, Value: 65535.000000
Path: UPS.ffff0010.[1].ffff0080, Type: Feature, ReportID: 0x72, Offset: 0, Size:
16, Value: 0.000000
Report descriptor retrieved (Reportlen = 924)
Found HID device
Detected a UPS: Hewlett-Packard /HP R1500 G2 UPS
upsdrv_initinfo...
upsdrv_updateinfo...
Got -110 HID objects...
Quick update...
dstate_init: sock /var/run/nut/usbhid-ups-HPR1500 open on fd 5
upsdrv_updateinfo...
Got -110 HID objects...
Quick update...