[Nut-upsuser] Hardware compatability report: Eaton Ellipse ECO 1600
Here is a Compatibility Report for the Eaton Ellipse ECO 1600 UPS. Roger battery.charge: 100 battery.charge.low: 20 battery.runtime: 1575 battery.type: PbAc device.mfr: EATON device.model: Ellipse ECO 1600 device.serial: 000000000 device.type: ups driver.name: usbhid-ups driver.parameter.lowbatt: 37 driver.parameter.offdelay: 30 driver.parameter.ondelay: 40 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: no driver.parameter.vendorid: 0463 driver.version: 2.7.4 driver.version.data: MGE HID 1.39 driver.version.internal: 0.41 input.transfer.high: 284 input.transfer.low: 161 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 2 outlet.1.status: on outlet.1.switchable: no outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 3 outlet.2.status: on outlet.2.switchable: no outlet.desc: Main Outlet outlet.id: 1 outlet.power: 25 outlet.switchable: no output.frequency.nominal: 50 output.voltage: 230.0 output.voltage.nominal: 230 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.firmware: 01 ups.load: 19 ups.mfr: EATON ups.model: Ellipse ECO 1600 ups.power.nominal: 1600 ups.productid: ffff ups.serial: 000000000 ups.status: OL ups.timer.shutdown: 0 ups.timer.start: 0 ups.vendorid: 0463 upsrw reports: [battery.charge.low] Remaining battery level when UPS switches to LB (percent) Type: STRING Maximum length: 5 Value: 20 [input.transfer.high] High voltage transfer point (V) Type: STRING Maximum length: 5 Value: 284 [input.transfer.low] Low voltage transfer point (V) Type: STRING Maximum length: 5 Value: 161 [outlet.1.desc] Outlet description Type: STRING Maximum length: 20 Value: PowerShare Outlet 1 [outlet.2.desc] Outlet description Type: STRING Maximum length: 20 Value: PowerShare Outlet 2 [outlet.2.switchable] Outlet switch ability Type: STRING Maximum length: 3 Value: no [outlet.desc] Outlet description Type: STRING Maximum length: 20 Value: Main Outlet [outlet.power] Description unavailable Type: ENUM Option: "10" Option: "25" SELECTED Option: "60" [output.voltage.nominal] Nominal output voltage (V) Type: ENUM Option: "220" Option: "230" SELECTED Option: "240" [ups.delay.shutdown] Interval to wait after shutdown with delay command (seconds) Type: STRING Maximum length: 10 Value: 20 [ups.delay.start] Interval to wait before (re)starting the load (seconds) Type: STRING Maximum length: 10 Value: 30 upscmd -l reports: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a delay (seconds) load.on - Turn on the load immediately load.on.delay - Turn on the load with a delay (seconds) shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress