2007 Aug 13
1
instcmd "beeper.off "
While working on the mge-hid subdriver, I wanted to add the 'beeper.mute' command. Unfortunately, the description I intended to use was used already by the 'beeper.off' instcmd: CMDDESC beeper.off "Temporarily mute the UPS beeper" Now of course we could add another instcmd 'beeper.reallyoff', but instead I would prefer to bite the b...
2012 Sep 19
2
Unable to disable beeper on Powercom Imperial IMP-525AP
Hi ALL, Powercom Imperial IMP-525AP seems to be fully compatible with NUT. Unfortunately, I can not disable beeper. upscmd -u {NUT_USER} -p {NUT_PASSWORD} powercom beeper.toggle returns *OK*, however, ups.beeper.status=enabled Thank you, Sergey ========== Additional info: 1) $ upsc powercom battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 30 battery.date: 2010/01/01 battery.runtime: 2432 ba...
2014 Aug 10
0
Power race? with Eaton 5E and how to auto-mute beeper
On Jul 26, 2014, at 9:58 AM, Leith Bade <leith at leithalweapon.geek.nz> wrote: > First the beeper is annoying and loud and I worry it will wake everyone up at night. I read that you can mute the beeper temporarily (and this works) but that most UPSs do not allow you to permanently turn it off (I tried using upsrw but it said beeper.status was read only). Can you send the variable list of upsrw...
2014 Jul 26
4
Power race? with Eaton 5E and how to auto-mute beeper
...ve a brand new Eaton 5E UPS purchased in Australia. Details: Eaton 5E Model: 5E650iUSB-AU Date: best I can find is the shipping date to supplier on box label - May 2014 OS: Ubuntu 14.04 Server edition Nut 2.7.1 Installed via apt-get install nut I have two problems I would like to fix. First the beeper is annoying and loud and I worry it will wake everyone up at night. I read that you can mute the beeper temporarily (and this works) but that most UPSs do not allow you to permanently turn it off (I tried using upsrw but it said beeper.status was read only). So is there a way to auto-mute the beep...
2009 May 08
1
Battery test feature of APC Back-UPS RS series
Hi all, I use an APC Back-UPS RS 800, overall my experience with NUT is very good but there is one feature I am missing: the ability to ask the UPS for a battery test. upscmd -l shows the following commands available: $ upscmd -l rs800 Instant commands supported on UPS [rs800]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a...
2016 Dec 03
3
Problem installing NUT on 16.04
...st address. The "LISTEN 127.0.0.1 3493" line in upsd.conf is sufficient for local control and monitoring, and you can remove "LISTEN ::1 3493". OK, did that restarted services and: mythuser at amethi:/etc/nut$ upscmd -l CyberUPS1 Instant commands supported on UPS [CyberUPS1]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a...
2019 Jan 01
2
Turn on UPS via USB
...ameter.port: auto driver.parameter.serial: 4B1207P41794 driver.parameter.vendorid: 051d driver.version: 2.6.5 driver.version.data: APC HID 0.95 driver.version.internal: 0.37 input.sensitivity: medium input.transfer.high: 139 input.transfer.low: 88 input.voltage: 118.0 input.voltage.nominal: 120 ups.beeper.status: disabled ups.delay.shutdown: 20 ups.firmware: 867.L6 .D ups.firmware.aux: L6 ups.load: 0 ups.mfr: American Power Conversion ups.mfr.date: 2012/02/18 ups.model: Back-UPS NS 1250G ups.productid: 0002 ups.realpower.nominal: 750 ups.serial: 4B1207P41794 ups.status: OL OFF ups.test.result: No te...
2012 Apr 26
1
[HCL] CyberPower Systems PR6000LCDRTXL5U supported by usbhid-ups
....parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version: 2.6.3 driver.version.data: CyberPower HID 0.3 driver.version.internal: 0.35 input.transfer.high: 254 input.transfer.low: 147 input.voltage: 240.0 input.voltage.nominal: 112 output.voltage: 207.0 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 46 ups.mfr: CyberPower Systems ups.model: PR6000LCDRTXL5U ups.productid: 0601 ups.realpower.nominal: 4500 ups.status: OL ups.timer.shutdown: 0 ups.timer.start: 0 ups.vendorid: 0764 # upsrw [battery.charge.low] Remaining batt...
2008 Dec 01
1
APC Back-UPS CS 500 power cycle
...omaticly turn on after power is back. A 'upsdrvctl shutdown' in the halt.local does not turn off the ups. A 'upscmd apc load.off.delay 5' works, but the ups does not turn on after power is back. Here the output of 'upscmd -l apc' : Instant commands supported on UPS [apc]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a...
2007 Oct 11
1
Silence Beeper => Which small UPS's actually support it?
Hello, I'm looking for a UPS that the beeper can be silenced with nut via ups.beeper.status variable for a HTPC close to bedrooms. I have googled extensively and there is not a lot of information about which UPS's actually support this feature. There are few references to UPS's that apparently list ups.beeper.status as being...
2012 Nov 23
1
Unable to disable beeper on Powercom Imperial IMP-525AP [SOLVED]
Hi Arnaud, I received several replies from technical support. It turned out that according to the UPS serial number it had been manufactured in 2012. So, the device should support the ability to disable the beeper. But still I can not disable the beeper using the latest version of UPSMON Plus in Windows: http://www.pcm.ru/data/download/public/soft/setup_upsmon_v2.9.rar (don't know why; the device was tested on XP/Win7 with different USB cables) [WORKAROUND] However, beeper can be disabled with the button...
2019 Jan 02
4
Turn on UPS via USB
...stop >> the beeping. >> So the system is still up on 1 PSU, and can talk to both UPS. Can't I turn >> on the load via USB? > > None of the supported commands seem to do the job. > > # upscmd -l aixapc > Instant commands supported on UPS [aixapc]: > > beeper.disable - Disable the UPS beeper > beeper.enable - Enable the UPS beeper > beeper.mute - Temporarily mute the UPS beeper > beeper.off - Obsolete (use beeper.disable or beeper.mute) > beeper.on - Obsolete (use beeper.enable) > load.off - Turn off the load immediately > load.off.del...
2015 Jul 27
0
[HCL] Eaton 5E1100i supported by usbhid-ups
...: 0463 driver.version: 2.7.1 driver.version.data: MGE HID 1.32 driver.version.internal: 0.38 input.voltage: 227.0 outlet.1.status: on outlet.desc: Main Outlet outlet.id: 1 outlet.switchable: no output.frequency: 49.9 output.frequency.nominal: 50 output.voltage: 228.0 output.voltage.nominal: 230 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.firmware: 01.04.0018 ups.load: 8 ups.mfr: EATON ups.model: 5E 1100i ups.power.nominal: 1100 ups.productid: ffff ups.start.battery: yes ups.status: OL CHRG ups.timer.shutdown: -1 ups.vendorid: 0463 *upsrw eaton5e* [outlet.desc] Outlet description Type: STR...
2014 Aug 10
1
Power race? with Eaton 5E and how to auto-mute beeper
...laces the Nova. Do they perhaps share hardware/firmware? Thanks, Leith Bade leith at leithalweapon.geek.nz On 10 August 2014 10:16, Charles Lepple <clepple at gmail.com> wrote: > On Jul 26, 2014, at 9:58 AM, Leith Bade <leith at leithalweapon.geek.nz> wrote: > >> First the beeper is annoying and loud and I worry it will wake everyone up at night. I read that you can mute the beeper temporarily (and this works) but that most UPSs do not allow you to permanently turn it off (I tried using upsrw but it said beeper.status was read only). > > Can you send the variable list...
2013 Aug 08
0
shutdown.* and load.*, and how to possibly add more instcmd for bcmxcp
....battery.start") 18 ("load.off") 16 ("load.on") 11 ("test.battery.stop") 8 ("shutdown.stop") 8 ("shutdown.reboot") 6 ("test.panel.start") 5 ("test.failure.start") 5 ("beeper.enable") 4 ("shutdown.reboot.graceful") 4 ("reset.input.minmax") 4 ("beeper.mute") 3 ("test.failure.stop") 3 ("test.battery.start.quick") 3 ("test.battery.start.deep") 3 ("bypass.s...
2017 May 14
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
...iver.parameter.productid: 0501 driver.parameter.serial: CTHGN200xxxx driver.parameter.synchronous: no driver.parameter.vendorid: 0764 driver.version: 2.7.4 driver.version.data: CyberPower HID 0.4 driver.version.internal: 0.41 input.voltage: 121.0 input.voltage.nominal: 120 output.voltage: 137.0 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 18 ups.mfr: CPS ups.model: CP1500AVRLCDa ups.productid: 0501 ups.realpower.nominal: 900 ups.serial: CTHGN200xxxx ups.status: OL ups.test.result: No test initiated ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764...
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
...val: 15 driver.parameter.port: auto driver.parameter.productid: 0501 driver.parameter.synchronous: no driver.parameter.vendorid: 0764 driver.version: 2.7.4 driver.version.data: CyberPower HID 0.4 driver.version.internal: 0.41 input.voltage: 121.0 input.voltage.nominal: 120 output.voltage: 129.0 ups.beeper.status: enabled ups.delay.shutdown: 60 ups.delay.start: 120 ups.load: 2 ups.mfr: CPS ups.model: AVRG750U ups.productid: 0501 ups.realpower.nominal: 450 ups.serial: <REDACTED> ups.status: OL ups.test.result: Done and passed ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 upsrw...
2020 Jan 08
0
Hardware compatability report: Eaton Ellipse ECO 1600
...2 outlet.1.status: on outlet.1.switchable: no outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 3 outlet.2.status: on outlet.2.switchable: no outlet.desc: Main Outlet outlet.id: 1 outlet.power: 25 outlet.switchable: no output.frequency.nominal: 50 output.voltage: 230.0 output.voltage.nominal: 230 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.firmware: 01 ups.load: 19 ups.mfr: EATON ups.model: Ellipse ECO 1600 ups.power.nominal: 1600 ups.productid: ffff ups.serial: 000000000 ups.status: OL ups.timer.shutdown: 0 ups.timer.start: 0 ups.vendorid: 0463 upsrw reports: [battery....
2016 Dec 03
0
Problem installing NUT on 16.04
...3" line in upsd.conf is sufficient >> for local control and monitoring, and you can remove "LISTEN ::1 3493". > > OK, did that restarted services and: > > mythuser at amethi:/etc/nut$ upscmd -l CyberUPS1 > Instant commands supported on UPS [CyberUPS1]: > > beeper.disable - Disable the UPS beeper > beeper.enable - Enable the UPS beeper > beeper.mute - Temporarily mute the UPS beeper > beeper.off - Obsolete (use beeper.disable or beeper.mute) > beeper.on - Obsolete (use beeper.enable) > load.off - Turn off the load immediately > load.off.del...
2019 Jan 02
0
Turn on UPS via USB
...ck in, but turned off the load - presumably to stop > the beeping.   > So the system is still up on 1 PSU, and can talk to both UPS.  Can't I turn > on the load via USB? None of the supported commands seem to do the job. # upscmd -l aixapc Instant commands supported on UPS [aixapc]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a...