2018 May 12
5
Tripp Lite SU5000RT3U
On May 8, 2018, at 10:05 PM, Charles Lepple <clepple at gmail.com> wrote:
>
>> I'm new to this, so let me know what you need from me and I will try my best. This UPS does power our production servers, so shutting things down aren't an easy task, but this weekend might open up some opportunity for that if need be. If I need to test it by unplugging the main power, that I can
2023 Nov 22
1
APC Modbus support is finally here!
...e". but the new value
> will only show after restarting apc_modbus. and in my case the written
> data will shift one day. eg the command "upsrw -s
> battery.date=2023-09-13" will return "2023-09-12" later.
> 2. the upscmd power-off related commands (like load.*, outlet.*,
> shutdown.*) can not work. so it can not shutdown the ups. (I think
> this is the most important feature which needs to be fixed)
> 3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
> test.battery.start, test.battery.stop, test.panel.start
> 4. I can't attach...
2023 Nov 22
1
APC Modbus support is finally here!
...e". but the new value
> will only show after restarting apc_modbus. and in my case the written
> data will shift one day. eg the command "upsrw -s
> battery.date=2023-09-13" will return "2023-09-12" later.
> 2. the upscmd power-off related commands (like load.*, outlet.*,
> shutdown.*) can not work. so it can not shutdown the ups. (I think
> this is the most important feature which needs to be fixed)
> 3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
> test.battery.start, test.battery.stop, test.panel.start
> 4. I can't attach...
2023 Nov 24
1
APC Modbus support is finally here!
...new value
>> will only show after restarting apc_modbus. and in my case the written
>> data will shift one day. eg the command "upsrw -s
>> battery.date=2023-09-13" will return "2023-09-12" later.
>> 2. the upscmd power-off related commands (like load.*, outlet.*,
>> shutdown.*) can not work. so it can not shutdown the ups. (I think
>> this is the most important feature which needs to be fixed)
>> 3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
>> test.battery.start, test.battery.stop, test.panel.start
>> 4....
2023 Nov 24
1
APC Modbus support is finally here!
...new value
>> will only show after restarting apc_modbus. and in my case the written
>> data will shift one day. eg the command "upsrw -s
>> battery.date=2023-09-13" will return "2023-09-12" later.
>> 2. the upscmd power-off related commands (like load.*, outlet.*,
>> shutdown.*) can not work. so it can not shutdown the ups. (I think
>> this is the most important feature which needs to be fixed)
>> 3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
>> test.battery.start, test.battery.stop, test.panel.start
>> 4....
2023 Nov 22
1
APC Modbus support is finally here!
...le "battery.date". but the new value
will only show after restarting apc_modbus. and in my case the written
data will shift one day. eg the command "upsrw -s
battery.date=2023-09-13" will return "2023-09-12" later.
2. the upscmd power-off related commands (like load.*, outlet.*,
shutdown.*) can not work. so it can not shutdown the ups. (I think
this is the most important feature which needs to be fixed)
3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
test.battery.start, test.battery.stop, test.panel.start
4. I can't attach any load so I can not tes...
2023 Nov 22
1
APC Modbus support is finally here!
...le "battery.date". but the new value
will only show after restarting apc_modbus. and in my case the written
data will shift one day. eg the command "upsrw -s
battery.date=2023-09-13" will return "2023-09-12" later.
2. the upscmd power-off related commands (like load.*, outlet.*,
shutdown.*) can not work. so it can not shutdown the ups. (I think
this is the most important feature which needs to be fixed)
3. upscmd command works: beeper.mute, bypass.start, bypass.stop,
test.battery.start, test.battery.stop, test.panel.start
4. I can't attach any load so I can not tes...
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
...rrent: 0.00
input.frequency: 59.9
input.frequency.extended: no
input.frequency.nominal: 60
input.sensitivity: normal
input.transfer.boost.low: 102
input.transfer.high: 151
input.transfer.low: 89
input.transfer.trim.high: 132
input.voltage: 116.7
input.voltage.extended: no
input.voltage.nominal: 120
outlet.1.autoswitch.charge.low: 0
outlet.1.current: 3.70
outlet.1.delay.shutdown: 65535
outlet.1.delay.start: 3
outlet.1.desc: PowerShare Outlet 1
outlet.1.id: 1
outlet.1.power: 432
outlet.1.powerfactor: 94.00
outlet.1.realpower: 410
outlet.1.status: on
outlet.1.switchable: yes
outlet.2.autoswitch.charge....
2007 Feb 01
2
NUT-2.0.3 - problems on setting values
Hello,
we have a MGE Pulsar Evolution 800 connected to a Fedora Core5 Server
using a serial cable.
Installed and configured properly are RPM versions of
nut-2.0.3-0.1.fc5
nut-client-2.0.3-0.1.fc5
nut-cgi-2.0.3-0.1.fc5
which all work (mostly) fine.
The server is connected to outlet.0 and properly shuts down when it's
loosing power after around 20 minutes. It also boots up whenever the ups
is getting power again.
To outlet.1 there are a few components like a router, a small switch and
a phone connected.
As to our understanding of , outlet.1.autoswitch.charge.low and...
2023 Nov 18
1
APC Modbus support is finally here!
Got an update for APC Modbus users: a new PR is waiting for real-life
testing for settable variables and instant commands support.
https://github.com/networkupstools/nut/pull/2184
As before, a custom build of libmodbus may be needed for USB support
(detailed in the earlier PR), but Serial and TCP may already be well served
by a distro near you!
Jim
On Sun, Oct 22, 2023, 01:08 Jim Klimov
2023 Nov 18
1
APC Modbus support is finally here!
Got an update for APC Modbus users: a new PR is waiting for real-life
testing for settable variables and instant commands support.
https://github.com/networkupstools/nut/pull/2184
As before, a custom build of libmodbus may be needed for USB support
(detailed in the earlier PR), but Serial and TCP may already be well served
by a distro near you!
Jim
On Sun, Oct 22, 2023, 01:08 Jim Klimov
2023 Nov 27
1
APC Modbus support is finally here!
...when
I configured upssched for early shutdown. I had only saw one very old
APC ups which will show "OB" when testing/calibration. most will show
like "OL DISCHRG". but I think the information is from ups and can not
change?
4. almost all the power-related upscmd command(load.* outlet.*
shutdown.*) are not working. there is only one exception: ouetlet1.*
works at SMT2200RM2U (I test outlet.1.load.off). nothing works at
SRT3000XL. the new driver detect there are two outlet groups for both
UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
since the new driver...
2023 Nov 27
1
APC Modbus support is finally here!
...when
I configured upssched for early shutdown. I had only saw one very old
APC ups which will show "OB" when testing/calibration. most will show
like "OL DISCHRG". but I think the information is from ups and can not
change?
4. almost all the power-related upscmd command(load.* outlet.*
shutdown.*) are not working. there is only one exception: ouetlet1.*
works at SMT2200RM2U (I test outlet.1.load.off). nothing works at
SRT3000XL. the new driver detect there are two outlet groups for both
UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
since the new driver...
2007 Jan 09
1
Differences between newhidups (MGE tables) in 2.0.4 and svn trunk
I was looking at how other drivers deal with outlet collections, and I
noticed some differences between newhidups in 2.0.4 (from Debian's
2.0.4-2.3) and the SVN trunk (rev 723) on an Evolution. Full diff is
below, but here are the highlights:
* MGE HID 0.9 vs 1.0
* outlet.#.switch seems to have moved to the commands outlet.#.load.{on,off}
Th...
2018 May 25
0
Tripp Lite SU5000RT3U
...tage.nominal: 48
device.mfr: Tripp Lite
device.model: TRIPP LITE UPS
device.type: ups
driver.name: tripplite_usb
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: no
driver.version: 2.7.4-480-g14301bdb
driver.version.internal: 0.29
input.voltage.nominal: 208
outlet.1.desc: Load 1
outlet.1.id: 1
outlet.1.switch: 1
outlet.1.switchable: 1
outlet.2.desc: Load 2
outlet.2.id: 2
outlet.2.switch: 1
outlet.2.switchable: 1
outlet.3.desc: Load 3
outlet.3.id: 3
outlet.3.switch: 1
outlet.3.switchable: 1
outlet.4.desc: Load 4
outlet.4.id: 4
outlet.4.switch: 1
outlet.4.swit...
2023 Oct 21
1
APC Modbus support is finally here!
Hello fellow NUTs :)
It is my great pleasure to get a bit of sunshine from other people's
work, and announce that the initial pull request for `apc_modbus` NUT
driver has recently been merged to the main NUT codebase, so it would be
part of an eventual 2.8.1 release. Great thanks go to Axel Gembe for the
implementation, and to numerous community members for testing as well as
their bug-fix
2023 Oct 21
1
APC Modbus support is finally here!
Hello fellow NUTs :)
It is my great pleasure to get a bit of sunshine from other people's
work, and announce that the initial pull request for `apc_modbus` NUT
driver has recently been merged to the main NUT codebase, so it would be
part of an eventual 2.8.1 release. Great thanks go to Axel Gembe for the
implementation, and to numerous community members for testing as well as
their bug-fix
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
...PbAc
battery.voltage: 43.0
driver.name: usbhid-ups
driver.parameter.offdelay: 120
driver.parameter.ondelay: 13
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version: 2.2.0
driver.version.data: MGE HID 1.0
driver.version.internal: 0.30
input.frequency: 50.0
input.voltage: 243.0
outlet.0.desc: Main Outlet
outlet.0.id: 0
outlet.0.switchable: yes
outlet.1.autoswitch.charge.low: 0
outlet.1.delay.shutdown: 2592000
outlet.1.delay.start: 1
outlet.1.desc: PowerShare Outlet 1
outlet.1.id: 1
outlet.1.status: off
outlet.1.switchable: yes
outlet.2.autoswitch.charge.low: 0
outlet.2.delay.shu...
2023 Nov 27
2
APC Modbus support is finally here!
...hed for early shutdown. I had only saw one very old
> APC ups which will show "OB" when testing/calibration. most will show
> like "OL DISCHRG". but I think the information is from ups and can not
> change?
>
> 4. almost all the power-related upscmd command(load.* outlet.*
> shutdown.*) are not working. there is only one exception: ouetlet1.*
> works at SMT2200RM2U (I test outlet.1.load.off). nothing works at
> SRT3000XL. the new driver detect there are two outlet groups for both
> UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
&...
2023 Nov 27
2
APC Modbus support is finally here!
...hed for early shutdown. I had only saw one very old
> APC ups which will show "OB" when testing/calibration. most will show
> like "OL DISCHRG". but I think the information is from ups and can not
> change?
>
> 4. almost all the power-related upscmd command(load.* outlet.*
> shutdown.*) are not working. there is only one exception: ouetlet1.*
> works at SMT2200RM2U (I test outlet.1.load.off). nothing works at
> SRT3000XL. the new driver detect there are two outlet groups for both
> UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
&...