Displaying 20 results from an estimated 9000 matches similar to: "Hardware compatability report: Eaton Ellipse ECO 1600"
2017 Apr 07
0
[Eaton 5S 1500] overvoltage shut down?
Hello Charles,
I've attached a dump below. There were no long entries on any of the hosts,
neither the one running standalone, nor the master/slave combo, which is
not too surprising, it was really fast: I saw the light flickering in the
room, almost like flash, and all those 3 systems went down. I first heard
the "click" of the ports being disabled, heard the systems shut down, and
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2010 Feb 22
2
PowerOff on Debian, and driver issues
Hi!
After some problems doing the automatic shutdown of the UPS on Debian, I
have found this Debian bug:
http://bugs.debian.org/cgi-bin/bugreport.cgi?bug=293401
Now I fixed it calling always ups-monitor from the halt script despite
being halt'ed' or powered off (and relying on the POWERDOWNFLAG be set).
Which is the correct aproach or best solution to workarround this bug?
And now my
2013 Feb 07
0
nut-2.6.5: ups.timer.start problem with EATON Protection Station 650
Hi,
I have successfully configured Nut to work with EATON PS 650: system
detects low battery, initiates shutdown, waits for UPS to switch power off.
However, when power is restored, UPS immediately powers on all power plugs
independently from ups.timer.start setting.
upsc reports "ups.timer.start" variable availability which is set to 0.
upsrw reports "ups.delay.start"
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
Hello!
We have two upses: MGE Pulsar M 3000 and MGE Pulsar EXtreme 3200C. They
connect to server by USB. EXtreme works good with usbhid-ups (nut 2.2.1) and
newhidups (nut 2.0.5). But Pulsar M doesn't want to work with usbhid-ups.
- my ups.conf:
[extreme]
driver = usbhid-ups
port = auto
product = "EXtreme"
[pulsar]
driver = usbhid-ups
port =
2012 Jul 18
1
Problem connecting to eaton ups. No matching HID UPS found. Driver failed to start(exit status=1)
Hi!
Info
OS: TinyCore Linux 4.5.6
NUT version: 2.6.4
NUT innstallation method: source tarball
Device name: Eaton Ellipse ups eco 1600 usb din (EL1600USBDIN)
/usr/local/ups/etc/ups.conf file:
[eaton]
driver = usbhid-ups
port = auto
When I run:
root at Dalen:/usr/local/ups/bin/upsdrvctl start eaton
I get this error message:
Network UPS Tools - UPS driver controller 2.6.4
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi,
This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status.
Details of our installation are:
OS: Debian 6
NUT version: 2.7.4
Installation method: from source tarball
UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi,
I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously,
the choice of this particular brand was mainly dictated by MGE's
long-standing support for Linux and NUT project. The fact that the box was
clearly the prettiest looking one on the block did help also ;-). I have had
NUT tools installed and configured in no time, as I did it numerous times
before -- kudos
2012 Jun 26
1
NUT MGE Pulsar Ellipse Premium 800: Changed NUT rw variables?
Hello all,
I've got an MGE Pulsar Ellipse Premium 800 powering a couple of FreeBSD
systems. Driver used is mge-shut, I don't know what the new mge-shut
driver offers, but I follow the "if it works, don't fix it" dogma here. :)
I also had a nut server installed on the master, with the
/usr/local/etc/rc.d/nut script slightly modified to include a couple of
upsrw commands
2016 May 04
2
New UPS Support: Eaton 5S 1000
Charles,
It starts out good, then goes into a Connection timed out loop. If I can
provide any information to fix a driver I'll do my best. Here's the output:
# /usr/local/ups/bin/usbhid-ups -DD -a eaton
Network UPS Tools - Generic HID driver 0.41 (2.7.4)
USB communication driver 0.33
0.000000 debug level is '2'
0.002550 upsdrv_initups...
0.288229 Checking device
2014 Dec 17
2
EATON 9SX not display battery.charge
OS version: FreeBSD 8.4-RELEASE-p19
NUT version: nut-2.7.2_6
NUT installation method: from freebsd pkg system
Device info: EATON 9SX 5000i, manufacturing date: 05.09.2014
ups.firmware: 9SX5Ki
When i try to see battery charge, in output it have not such variable,
and i can't control my server and other clients connected to them. Any
options cannot power of server. How to see current battery
2014 May 05
1
communication problems with eaton 9130 over usb
Hi!
I am not really experienced with UPS devices or UPS control software
like NUT but i am enthusiastic and trying to use Eaton-9130 (it has one
extra EBM too) as rationally as possible with NUT. I believe in general
things are under control and behave, although i have some glitches and i
would like to ask for help.
I am using Debian v. 7 amd64 and from its packages nut-server and
nut-client, v.
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
I am running NUT 2.2.0 compiled from the FreeBSD ports tree.
[inchoate 14:50] ~ >upsc ups1 at localhost
battery.charge: 59
battery.charge.low: 20
battery.charge.restart: 0
battery.runtime: 6350
battery.type: PbAc
battery.voltage: 43.0
driver.name: usbhid-ups
driver.parameter.offdelay: 120
driver.parameter.ondelay: 13
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version:
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote:
> Dear All,
>
> Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility?
>
> 850 or 1000 VA
>
> I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it.
>
> Thank you,
> Bart
Can you tell
2014 Jun 05
0
Question about voltage threshold setting in NUT
Hey Charles,
Latest update. Looks like in ups.conf I setup default.input.transfer.low =
84. After I took that line out, restart upsdrvctl, upsmon, and upsd, the
command of
sudo upsrw -s input.transfer.low=70 -u * -p * ups
return OK. Still need to verify if it works by using voltage regulator and
will keep you updated.
Thank you for your help
Regards
Shen
On Thu, Jun 5, 2014 at 8:54 AM,
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
Hi,
I've been using NUT for many years to look after the UPS on my home
servers. Originally I was using a Compaq R3000 but that was replaced
with an MGE Pulsar Evolution 3000 about a couple of years ago because
the Compaq one was just too noisy!
I'm just setting up a replacement server and would like to connect it
using a serial cable as I've found that the USB connection
2010 Oct 06
1
Model list missing my UPS, here is info for inclusion on the list
Hello Niels,
thanks a lot for this compatibility submission. This is part of the
remaining things at Eaton.
I've added an entry to the new Hardware Compatibility List:
http://new.networkupstools.org/stable-hcl.html
BTW, have you tested a shutdown with this unit?
Otherwise, you should!
thanks again,
Arnaud Quette
Le samedi 02 octobre 2010 ? 12:42 +0200, Niels Kristian Jensen a
?crit :
2014 Jun 05
2
Question about voltage threshold setting in NUT
Hello Charles,
Thank you so much for your help. Just run upsc and it is possible that
input.transfer.low is the one because we used power regulator to bring down
the power around 84v and then the ups sent the power loss message to PC. Do
you think some others may take effect for the low voltage? Just have the
upsc result attached.
Then I retried input.transfer.low, default.input.transfer.low,
2015 Jul 27
0
[HCL] Eaton 5E1100i supported by usbhid-ups
Device manufacturer and name: *Eaton 5E 1100i USB*
*upsc eaton5e*
Init SSL without certificate database
eaton5e
root at eger:/home/siposg# upsc eaton5e
Init SSL without certificate database
battery.charge: 100
battery.runtime: 3160
battery.type: PbAc
device.mfr: EATON
device.model: 5E 1100i
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2