[Nut-upsuser] APC SMX3000RMLV2UNC with AP9631 NUT compatibility via network
I have an APC SMX3000RMLV2UNC UPS, with installed network card model AP9631. http://www.apc.com/resource/include/techspec_index.cfm?base_sku=SMX3000RMLV2UNC http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9631 I planned to use network connectivity with this unit and apcupsd, but have not this far. The UPS is shared by multiple servers, so a USB or Serial connection via the AP9620 is not feasible: http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9620 I found and started researching NUT, and would prefer using NUT with this APC and future purchases of NUT-compatible hardware from OEMs other than APC, e.g. Eaton. I see a prior thread discussing the unfortunate proprietary microlink protocol: Subject: Re: APC Smart-UPS 1200 Date: 2012-10-04 14:55:55 GMT My question is whether microlink is what is actually used for a TCP/IP connection to the AP9631 network card, or whether another protocol such as SNMP is available for NUT to use. Even a lower count of UPS metrics via SNMP would be usable, I just need to reliably signal on power loss events. Thanks for any comments from APC users of this or similar equipment. I'm looking forward to using it with NUT, or at least finding out that it can't be done. Thanks, Jeff
Kris Jordan
2013-Feb-26 06:16 UTC
[Nut-upsuser] APC SMX3000RMLV2UNC with AP9631 NUT compatibility via network
Jeff Kowalczyk wrote, On 2/25/2013 4:09 PM:> I have an APC SMX3000RMLV2UNC UPS, with installed network card model AP9631. > > http://www.apc.com/resource/include/techspec_index.cfm?base_sku=SMX3000RMLV2UNC > http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9631http://www.networkupstools.org/docs/man/snmp-ups.html I don't see the 9631, so it might not work.> I planned to use network connectivity with this unit and apcupsd, but have not > this far. The UPS is shared by multiple servers, so a USB or Serial connection > via the AP9620 is not feasible: > > http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9620You don't have to use a SNMP card to shutdown multiple systems. NUT can handle this quite well. I'd expect NUT to work with the AP9620 legacy communications card using either the apcsmart (serial) or usbhid-ups (USB) drivers. I don't recall anyway saying for sure though.> I see a prior thread discussing the unfortunate proprietary microlink protocol: > > Subject: Re: APC Smart-UPS 1200 > Date: 2012-10-04 14:55:55 GMT > > My question is whether microlink is what is actually used for a TCP/IP > connection to the AP9631 network card, or whether another protocol such as SNMP > is available for NUT to use. Even a lower count of UPS metrics via SNMP would be > usable, I just need to reliably signal on power loss events.I'm pretty sure Microlink is just for serial and USB on any current Smart-UPS model.