[Nut-upsuser] [HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
The REDi Blazer 600VA (BLAZER600c) UPS found here [ro_RO]: http://www.emag.ro/ups-redi-blazer-600va-blazer600c/pd/EX5X2BBBM/ which is actually a Centralion Blazer 600VA [en_TW]: http://www.centralion.com/html/product/back-Product-ups-blazer400.htm works with the blazer_ser driver ----------shell output---------- # upsrw ups # upscmd -l ups Instant commands supported on UPS [ups]: beeper.toggle - Toggle the UPS beeper load.off - Turn off the load immediately load.on - Turn on the load immediately shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress test.battery.start - Start a battery test test.battery.start.deep - Start a deep battery test test.battery.start.quick - Start a quick battery test test.battery.stop - Stop the battery test # upsc ups battery.voltage: 13.60 battery.voltage.nominal: 12.0 beeper.status: enabled device.type: ups driver.name: blazer_ser driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ttyS0 driver.version: 2.6.3 driver.version.internal: 1.51 input.current.nominal: 2.0 input.frequency: 49.9 input.frequency.nominal: 50 input.voltage: 238.7 input.voltage.fault: 238.7 input.voltage.nominal: 230 output.voltage: 238.7 ups.delay.shutdown: 30 ups.delay.start: 180 ups.load: 17 ups.status: OL ups.temperature: 25.0 ups.type: offline / line interactive ----------cut here---------- I have also run `upsmon -c fsd`, which powers off the server and after 30 seconds powers off the UPS, but the UPS does *not* start up automatically afterwards. This is the only problem I had so far The report above should apply to: * REDi/Centralion Blazer 400VA * REDi/Centralion Blazer 600VA * REDi/Centralion Blazer 800VA [ since these three are the same UPS with different batteries ] and might also apply to the other REDi/Centralion Blazer UPSes If you would like any more information, please tell me -- Marius Gavrilescu (etc) They laughed at Einstein. They laughed at the Wright Brothers. But they also laughed at Bozo the Clown. --Carl Sagan -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 836 bytes Desc: Digital signature URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120609/1309c65d/attachment.pgp>
Arnaud Quette
2012-Jun-11 14:01 UTC
[Nut-upsuser] [HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
Hi Marius, 2012/6/9 Marius Gavrilescu <gmariusx at yahoo.com>> The REDi Blazer 600VA (BLAZER600c) UPS found here [ro_RO]: > http://www.emag.ro/ups-redi-blazer-600va-blazer600c/pd/EX5X2BBBM/ > which is actually a Centralion Blazer 600VA [en_TW]: > http://www.centralion.com/html/product/back-Product-ups-blazer400.htm > works with the blazer_ser driver > > ----------shell output---------- > # upsrw ups > # upscmd -l ups > Instant commands supported on UPS [ups]: > > beeper.toggle - Toggle the UPS beeper > load.off - Turn off the load immediately > load.on - Turn on the load immediately > shutdown.return - Turn off the load and return when power is back > shutdown.stayoff - Turn off the load and remain off > shutdown.stop - Stop a shutdown in progress > test.battery.start - Start a battery test > test.battery.start.deep - Start a deep battery test > test.battery.start.quick - Start a quick battery test > test.battery.stop - Stop the battery test > # upsc ups > battery.voltage: 13.60 > battery.voltage.nominal: 12.0 > beeper.status: enabled > device.type: ups > driver.name: blazer_ser > driver.parameter.pollinterval: 2 > driver.parameter.port: /dev/ttyS0 > driver.version: 2.6.3 > driver.version.internal: 1.51 > input.current.nominal: 2.0 > input.frequency: 49.9 > input.frequency.nominal: 50 > input.voltage: 238.7 > input.voltage.fault: 238.7 > input.voltage.nominal: 230 > output.voltage: 238.7 > ups.delay.shutdown: 30 > ups.delay.start: 180 > ups.load: 17 > ups.status: OL > ups.temperature: 25.0 > ups.type: offline / line interactive > ----------cut here---------- > > I have also run `upsmon -c fsd`, which powers off the server > and after 30 seconds powers off the UPS, but the UPS does *not* start up > automatically afterwards. This is the only problem I had so far > > The report above should apply to: > * REDi/Centralion Blazer 400VA > * REDi/Centralion Blazer 600VA > * REDi/Centralion Blazer 800VA > [ since these three are the same UPS with different batteries ] > and might also apply to the other REDi/Centralion Blazer UPSes > > If you would like any more information, please tell me >thanks for your detailed report. I've committed to the trunk (r3654) an entry in the HCL: http://trac.networkupstools.org/projects/nut/changeset/3654 A side note for the FSD test: Default values are offdelay = 30 seconds, and ondelay = 3 minutes. So you may have not waited enough... cheers, Arnaud -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120611/f0f3b666/attachment.html>
Marius Gavrilescu
2012-Jun-11 14:13 UTC
[Nut-upsuser] [HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
On Mon, Jun 11, 2012 at 04:01:55PM +0200, Arnaud Quette wrote:> Default values are offdelay = 30 seconds, and ondelay = 3 minutes. > So you may have not waited enough...3 minutes is quite a lot. Is there any way to lower it? -- Marius Gavrilescu (science-kids) Humidity is the experience of looking for air and finding water. -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 836 bytes Desc: Digital signature URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120611/93a5904c/attachment.pgp>
Arnaud Quette
2012-Jun-11 14:30 UTC
[Nut-upsuser] [HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
2012/6/11 Marius Gavrilescu <gmariusx at yahoo.com>> On Mon, Jun 11, 2012 at 04:01:55PM +0200, Arnaud Quette wrote: > > Default values are offdelay = 30 seconds, and ondelay = 3 minutes. > > So you may have not waited enough... > > 3 minutes is quite a lot.an eternity in the IT world ;-)> Is there any way to lower it? >as (almost) everything in NUT: http://www.networkupstools.org/docs/man/blazer.html check for ondelay. as described, the default (min) value of 3 is for a wider compatibility. that said, you can put "ondelay = 1" in your ups.conf device section. cheers, Arnaud -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120611/037e24c5/attachment.html>