Lucas Rossi
2024-Sep-22 22:03 UTC
[Nut-upsdev] [HCL] Liebert GXT4-1500RT120 supported by usbhid-ups
Liebert GXT4-1500RT120 upsc output: battery.charge: 100 battery.charge.low: 30 battery.charge.warning: 40 battery.type: PbAcbattery.voltage: 54 battery.voltage.nominal: 48 device.mfr: Emerson Network Power device.model: Liebert GXT4 device.serial: 1710600384AFBA3 device.type: ups driver.debug: 0 driver.flag.allow_killpower: 0 driver.flag.ignorelb: enableddriver.name: usbhid-ups driver.parameter.default.battery.voltage: 54 driver.parameter.default.battery.voltage.nominal: 48 driver.parameter.default.input.voltage: 120 driver.parameter.default.input.voltage.nominal: 120 driver.parameter.override.battery.charge.low: 30 driver.parameter.override.battery.charge.warning: 40 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.synchronous: auto driver.state: quiet driver.version: 2.8.1.1 driver.version.data: Belkin/Liebert HID 0.18 driver.version.internal: 0.52 driver.version.usb: libusb-1.0.0 (API: 0x1000102)input.voltage: 120 input.voltage.nominal: 120 ups.mfr: Emerson Network Power ups.model: Liebert GXT4 ups.productid: 0000 ups.serial: 1710600384AFBA3 ups.status: OL CHRG ups.vendorid: 10af upsrw output: [driver.debug] Current debug verbosity level of the driver program Type: NUMBER Value: 0 [driver.flag.allow_killpower] Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower) Type: NUMBER Value: 0 upsrw -l output: Instant commands supported on UPS [ups]: driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting driver.reload - Reload running driver configuration from the file system (only works for changes in some options) driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options) driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options) usbhid arguments: desc = "Emerson Network Power Liebert GXT4" productid = 0000 ignorelb override.battery.charge.warning = 40 override.battery.charge.low = 30 default.input.voltage.nominal = 120 default.input.voltage = 120 default.battery.voltage.nominal = 48 default.battery.voltage = 54 UPS shutdown has been tested. I suspect these same parameters will also work for other GXT4 models and the GXT3 family as well, since they seem to share the same controller. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20240922/bb16b849/attachment.htm>