Displaying 20 results from an estimated 20 matches for "allow_killpower".
2023 Nov 12
0
Salicru and usbhid-ups
...ENT:
# First report for new salicru HID subdriver from PR referenced
# above for Salicru SPS 2000 ADV T.
# NOTE: I (like abelgomez ) tried to set the value of
# `battery.charge.low` using `upsrw`, but although the command returns
# OK, no values seem to be modified.
# I was able to set `driver.flag.allow_killpower`, but issuing
# `upscmd? -u ** -p ** ny driver.killpower` did nothing, even though it
replied
#? with 'OK'
# DEVICE:EOC
battery.charge: 100
battery.charge.low: 0
battery.charge.warning: 20
battery.runtime: 7200
battery.runtime.low: 400
battery.type: PbAcid
battery.voltage: 25.60
battery.vo...
2023 Nov 24
1
APC Modbus support is finally here!
...ery.date: 2023-11-21
>> battery.runtime: 57000.0
>> battery.runtime.low: 180
>> battery.voltage: 109.0
>> device.mfr: APC
>> device.model: Smart-UPS SRT 3000
>> device.serial: AS2032296523
>> device.type: ups
>> driver.debug: 0
>> driver.flag.allow_killpower: 0
>> driver.name: apcupsd-ups
>> driver.parameter.pollinterval: 10
>> driver.parameter.port: localhost
>> driver.parameter.synchronous: auto
>> driver.state: quiet
>> driver.version: 2.8.1
>> driver.version.internal: 0.71
>> input.frequency: 60.0
>...
2023 Nov 24
1
APC Modbus support is finally here!
...ery.date: 2023-11-21
>> battery.runtime: 57000.0
>> battery.runtime.low: 180
>> battery.voltage: 109.0
>> device.mfr: APC
>> device.model: Smart-UPS SRT 3000
>> device.serial: AS2032296523
>> device.type: ups
>> driver.debug: 0
>> driver.flag.allow_killpower: 0
>> driver.name: apcupsd-ups
>> driver.parameter.pollinterval: 10
>> driver.parameter.port: localhost
>> driver.parameter.synchronous: auto
>> driver.state: quiet
>> driver.version: 2.8.1
>> driver.version.internal: 0.71
>> input.frequency: 60.0
>...
2023 Nov 22
1
APC Modbus support is finally here!
...> battery.charge.low: 5
> battery.date: 2023-11-21
> battery.runtime: 57000.0
> battery.runtime.low: 180
> battery.voltage: 109.0
> device.mfr: APC
> device.model: Smart-UPS SRT 3000
> device.serial: AS2032296523
> device.type: ups
> driver.debug: 0
> driver.flag.allow_killpower: 0
> driver.name: apcupsd-ups
> driver.parameter.pollinterval: 10
> driver.parameter.port: localhost
> driver.parameter.synchronous: auto
> driver.state: quiet
> driver.version: 2.8.1
> driver.version.internal: 0.71
> input.frequency: 60.0
> input.voltage: 224.7
> outp...
2023 Nov 22
1
APC Modbus support is finally here!
...> battery.charge.low: 5
> battery.date: 2023-11-21
> battery.runtime: 57000.0
> battery.runtime.low: 180
> battery.voltage: 109.0
> device.mfr: APC
> device.model: Smart-UPS SRT 3000
> device.serial: AS2032296523
> device.type: ups
> driver.debug: 0
> driver.flag.allow_killpower: 0
> driver.name: apcupsd-ups
> driver.parameter.pollinterval: 10
> driver.parameter.port: localhost
> driver.parameter.synchronous: auto
> driver.state: quiet
> driver.version: 2.8.1
> driver.version.internal: 0.71
> input.frequency: 60.0
> input.voltage: 224.7
> outp...
2023 Nov 22
1
APC Modbus support is finally here!
...rom nut+apcupsd (for reference):
battery.charge: 99.0
battery.charge.low: 5
battery.date: 2023-11-21
battery.runtime: 57000.0
battery.runtime.low: 180
battery.voltage: 109.0
device.mfr: APC
device.model: Smart-UPS SRT 3000
device.serial: AS2032296523
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: apcupsd-ups
driver.parameter.pollinterval: 10
driver.parameter.port: localhost
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.1
driver.version.internal: 0.71
input.frequency: 60.0
input.voltage: 224.7
output.current: 0.00
output.frequency: 60.0
output.vol...
2023 Nov 22
1
APC Modbus support is finally here!
...rom nut+apcupsd (for reference):
battery.charge: 99.0
battery.charge.low: 5
battery.date: 2023-11-21
battery.runtime: 57000.0
battery.runtime.low: 180
battery.voltage: 109.0
device.mfr: APC
device.model: Smart-UPS SRT 3000
device.serial: AS2032296523
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: apcupsd-ups
driver.parameter.pollinterval: 10
driver.parameter.port: localhost
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.1
driver.version.internal: 0.71
input.frequency: 60.0
input.voltage: 224.7
output.current: 0.00
output.frequency: 60.0
output.vol...
2024 Sep 22
1
[HCL] Liebert GXT4-1500RT120 supported by usbhid-ups
...4-1500RT120
upsc output:
battery.charge: 100
battery.charge.low: 30
battery.charge.warning: 40
battery.type: PbAcbattery.voltage: 54
battery.voltage.nominal: 48
device.mfr: Emerson Network Power
device.model: Liebert GXT4
device.serial: 1710600384AFBA3
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.flag.ignorelb: enableddriver.name: usbhid-ups
driver.parameter.default.battery.voltage: 54
driver.parameter.default.battery.voltage.nominal: 48
driver.parameter.default.input.voltage: 120
driver.parameter.default.input.voltage.nominal: 120
driver.parameter.override.battery.charge.low: 30...
2023 Nov 27
1
APC Modbus support is finally here!
...groups for both
UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
since the new driver can not shutdown the ups, I wonder what's the
fastest method to test the function (previously I setup the ups and
unplug the utility from the ups for testing). is "upsrw
driver.flag.allow_killpower=1" then "upscmd driver.killpower" the
correct testing procedure?
5. the default/actual shutdown delay for both ups is 90 seconds(when
real testing under apcupsd). the "upsrw -l myups" has value "90" for
the attribute "outlet.group.1.delay.shutdown". but...
2023 Nov 27
1
APC Modbus support is finally here!
...groups for both
UPS(outlet.group.count: 2). but SMT2200RM2U has only one outlet group.
since the new driver can not shutdown the ups, I wonder what's the
fastest method to test the function (previously I setup the ups and
unplug the utility from the ups for testing). is "upsrw
driver.flag.allow_killpower=1" then "upscmd driver.killpower" the
correct testing procedure?
5. the default/actual shutdown delay for both ups is 90 seconds(when
real testing under apcupsd). the "upsrw -l myups" has value "90" for
the attribute "outlet.group.1.delay.shutdown". but...
2023 Nov 18
1
APC Modbus support is finally here!
Got an update for APC Modbus users: a new PR is waiting for real-life
testing for settable variables and instant commands support.
https://github.com/networkupstools/nut/pull/2184
As before, a custom build of libmodbus may be needed for USB support
(detailed in the earlier PR), but Serial and TCP may already be well served
by a distro near you!
Jim
On Sun, Oct 22, 2023, 01:08 Jim Klimov
2023 Nov 18
1
APC Modbus support is finally here!
Got an update for APC Modbus users: a new PR is waiting for real-life
testing for settable variables and instant commands support.
https://github.com/networkupstools/nut/pull/2184
As before, a custom build of libmodbus may be needed for USB support
(detailed in the earlier PR), but Serial and TCP may already be well served
by a distro near you!
Jim
On Sun, Oct 22, 2023, 01:08 Jim Klimov
2024 Sep 25
0
HCL Cleanline L-1000C nutdrv_qt
Cleanline L-1000C
upsc output:
Init SSL without certificate database
battery.charge: 100
battery.voltage: 13.2
battery.voltage.high: 13.00
battery.voltage.low: 10.40
battery.voltage.nominal: 12.0
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
[driver.name](http://driver.name/): nutdrv_qx
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.1
driver.version.data: Voltronic-QS 0.09
driver.version.internal: 0.36
driver.versio...
2023 Nov 27
2
APC Modbus support is finally here!
Thanks again,
Great to see confirmations of more and more things working!
> I wonder what's the fastest method to test the function (previously I
setup the ups and unplug the utility from the ups for testing).
> is "upsrw driver.flag.allow_killpower=1" then "upscmd driver.killpower"
the correct testing procedure?
At least by intent of this new feature -- yes. Normally the drivers are not
allowed to pass these dangerous commands unless started specifically for
killpower handling late in the system shutdown. Since NUT v2.8.1 howe...
2023 Nov 27
2
APC Modbus support is finally here!
Thanks again,
Great to see confirmations of more and more things working!
> I wonder what's the fastest method to test the function (previously I
setup the ups and unplug the utility from the ups for testing).
> is "upsrw driver.flag.allow_killpower=1" then "upscmd driver.killpower"
the correct testing procedure?
At least by intent of this new feature -- yes. Normally the drivers are not
allowed to pass these dangerous commands unless started specifically for
killpower handling late in the system shutdown. Since NUT v2.8.1 howe...
2023 Oct 21
1
APC Modbus support is finally here!
Hello fellow NUTs :)
It is my great pleasure to get a bit of sunshine from other people's
work, and announce that the initial pull request for `apc_modbus` NUT
driver has recently been merged to the main NUT codebase, so it would be
part of an eventual 2.8.1 release. Great thanks go to Axel Gembe for the
implementation, and to numerous community members for testing as well as
their bug-fix
2023 Oct 21
1
APC Modbus support is finally here!
Hello fellow NUTs :)
It is my great pleasure to get a bit of sunshine from other people's
work, and announce that the initial pull request for `apc_modbus` NUT
driver has recently been merged to the main NUT codebase, so it would be
part of an eventual 2.8.1 release. Great thanks go to Axel Gembe for the
implementation, and to numerous community members for testing as well as
their bug-fix
2023 Apr 19
2
Enhanced driver troubleshooting
Cheers,
With https://github.com/networkupstools/nut/pull/1906 and
https://github.com/networkupstools/nut/pull/1912 (and probably some more
later), I've been enhancing NUT driver framework with support for live
reload of configuration, primarily to acknowledge changes to debug_min
setting in ups.conf - but made in a generic fashion that specific drivers
may take advantage of for their
2023 Apr 19
2
Enhanced driver troubleshooting
Cheers,
With https://github.com/networkupstools/nut/pull/1906 and
https://github.com/networkupstools/nut/pull/1912 (and probably some more
later), I've been enhancing NUT driver framework with support for live
reload of configuration, primarily to acknowledge changes to debug_min
setting in ups.conf - but made in a generic fashion that specific drivers
may take advantage of for their
2024 Mar 04
0
Newer APC Back-UPS spurious events
...ge.low: 10
battery.mfr.date: 2001/01/01
battery.runtime: 659
battery.runtime.low: 120
battery.type: PbAc
battery.voltage: 27.3
battery.voltage.nominal: 24.0
device.mfr: American Power Conversion
device.model: Back-UPS BX1600MI
device.serial: 9B2339A15993
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: usbhid-ups
driver.parameter.poll freq: 30
driver.parameter.poll interval: 2
driver.parameter.port : auto
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.1-884-gf2fc47067
driver.version.data: APC HID 0.100
driver.version.internal: 0.52
driver.version.usb: l...