Kjell Claesson
2006-Apr-21 17:00 UTC
[Nut-upsdev] RE: [Nut-upsuser] SOS : Help needed for UPS CentralionBlazer2000VAUSB
Ok Guillaume, It is Megatec protocol. It sends Q1<cr> and answers with (227.2 227.2 227.2 038 50.1 13.5 25.0 00001001<cr> And if you check http://eu1.networkupstools.org/protocols/megatec.html it matches. And now, ho has time to code ? Kjell fre 2006-04-21 klockan 17:18 +0200 skrev Guillaume JAOUEN:> Hello, > > As I wish to help you the most I can in order to get a driver for Centralion > Blazer USB UPS, you will find a log of the USB activity of this UPS made > with SnoopyPro 0.22. > > I follow this events procedure : > > Start of the log : UPS status normal, the following data was delivered by > the UPS : > UPS Model : LIN-INT > UPS Port : USB > UPS temperature : 25,0?C > > AC INPUT : > Voltage : between 226 and 227 V > > AC OUTPUT : > OUTPUT LOAD : 38% > OUTPUT VOLTAGE : 225 V > OUTPUT FREQUENCY : 50,1 HZ > > BATTERY : > VOLTAGE : 13,0 V > STANDARD VOLTAGE : 12,0 V > CAPACITY : 100% > > 1 - AC INPUT shutdown until battery go to 62% of charge > 2 - AC INPUT back > 3 - Launch from the monitoring software the command for a self-test of 10 > sec (I wait until I get the success message for the test) > 4 - I disable the audible warning > 5 - I enable the audible warning > > End of the log. > > Please let me know if you need more things to be done. > > Regards, > Guillaume JAOUEN.
Guillaume JAOUEN
2006-May-02 08:29 UTC
[Nut-upsdev] RE: [Nut-upsuser] SOS : Help needed for UPSCentralionBlazer2000VAUSB
Hello Carlos, As you're working on a generic megatec protocol driver, I want to know if this driver will work with USB UPS. Regards, Guillaume JAOUEN. -----Message d'origine----- De?: Kjell Claesson [mailto:kjell.claesson@telia.com] Envoy??: vendredi 21 avril 2006 18:58 ??: Guillaume JAOUEN Cc?: 'Arnaud Quette'; 'Carlos Rodrigues'; nut-upsdev@lists.alioth.debian.org Objet?: Re: [Nut-upsdev] RE: [Nut-upsuser] SOS : Help needed for UPSCentralionBlazer2000VAUSB Ok Guillaume, It is Megatec protocol. It sends Q1<cr> and answers with (227.2 227.2 227.2 038 50.1 13.5 25.0 00001001<cr> And if you check http://eu1.networkupstools.org/protocols/megatec.html it matches. And now, ho has time to code ? Kjell fre 2006-04-21 klockan 17:18 +0200 skrev Guillaume JAOUEN:> Hello, > > As I wish to help you the most I can in order to get a driver forCentralion> Blazer USB UPS, you will find a log of the USB activity of this UPS made > with SnoopyPro 0.22. > > I follow this events procedure : > > Start of the log : UPS status normal, the following data was delivered by > the UPS : > UPS Model : LIN-INT > UPS Port : USB > UPS temperature : 25,0?C > > AC INPUT : > Voltage : between 226 and 227 V > > AC OUTPUT : > OUTPUT LOAD : 38% > OUTPUT VOLTAGE : 225 V > OUTPUT FREQUENCY : 50,1 HZ > > BATTERY : > VOLTAGE : 13,0 V > STANDARD VOLTAGE : 12,0 V > CAPACITY : 100% > > 1 - AC INPUT shutdown until battery go to 62% of charge > 2 - AC INPUT back > 3 - Launch from the monitoring software the command for a self-test of 10 > sec (I wait until I get the success message for the test) > 4 - I disable the audible warning > 5 - I enable the audible warning > > End of the log. > > Please let me know if you need more things to be done. > > Regards, > Guillaume JAOUEN.