Robert A. LaBudde
2012-Oct-08 14:54 UTC
[R] Mininum number of resamples required to do BCa bootstrap?
I'm using R 2.15.1 on a 64-bit machine with Windows 7 Home Premium and package 'boot'. I've found that using a number of bootstrap resamples in boot() that is less than the number of data results in a fatal error. Once the number of resamples meets or exceeds the number of data, the error disappears. Sample problem (screwy subscripted syntax is a relic of edited down a more complex script): > N <- 25 > s <- rlnorm(N, 0, 1) > require("boot") Loading required package: boot > v <- NULL # hold sample variance estimates > i <- 1 > v[i] <- var(s) # get sample variance > nReal <- 10 > varf <- function (x,i) { var(x[i]) } > fabc <- function (x, w) { # weighted average (biased) variance + sum(x^2 * w) / sum(w) - (sum(x * w) / sum(w))^2 + } > p <- c(.25, .75, .2, .8, .15, .85, .1, .9, .05, .95, .025, .975, .005, .995) > cl <- c(0.5, 0.6, 0.7, 0.8, 0.9, 0.95, 0.99) > b <- boot(s, varf, R = nReal) # bootstrap > bv <- NULL # hold bootstrap mean variance estimates > bias <- NULL #hold bias estimates > bv[i] <- mean(b$t) # bootstrap mean variance > bias[i] <- bv[i] - v[i] # bias estimate > bCI90 <- boot.ci(b, conf = 0.90) Error in bca.ci(boot.out, conf, index[1L], L = L, t = t.o, t0 = t0.o, : estimated adjustment 'a' is NA In addition: Warning messages: 1: In norm.inter(t, (1 + c(conf, -conf))/2) : extreme order statistics used as endpoints 2: In boot.ci(b, conf = 0.9) : bootstrap variances needed for studentized intervals 3: In norm.inter(t, alpha) : extreme order statistics used as endpoints > > nReal <- 25 > b <- boot(s, varf, R = nReal) # bootstrap > bv[i] <- mean(b$t) # bootstrap mean variance > bias[i] <- bv[i] - v[i] # bias estimate > bCI90 <- boot.ci(b, conf = 0.90) Warning messages: 1: In boot.ci(b, conf = 0.9) : bootstrap variances needed for studentized intervals 2: In norm.inter(t, adj.alpha) : extreme order statistics used as endpoints The problem is that doing 10 resamples generates an NA in the estimation of the 'acceleration' in the function abc.ci(), but doing 25 resamples does not. This implies a connection between the number of resamples and the 'acceleration' which should not exist. ('Acceleration' should be obtained from the original sample via jackknife as 1/6 the coefficient of skewness.) The script apparently works correctly if the number of resamples equals or exceeds the number of original data, but not otherwise. ===============================================================Robert A. LaBudde, PhD, PAS, Dpl. ACAFS e-mail: ral at lcfltd.com Least Cost Formulations, Ltd. URL: http://lcfltd.com/ 824 Timberlake Drive Tel: 757-467-0954 Virginia Beach, VA 23464-3239 Fax: 757-467-2947 "Vere scire est per causas scire"
Apparently Analagous Threads
- Possible error in BCa method for confidence intervals in package 'boot'
- Getting 'tilting' confidence intervals in R
- [R} Getting 'tilting' confidence intervals in R
- Confidence interval for binomial variance
- Bootstrap BCa confidence limits with your own resamples