Hi all, Yet another story regarding mpt issues, and in order to make a long story short everytime that a Dell R710 running snv_134 logs the information scsi: [ID 107833 kern.warning] WARNING: /pci at 0,0/pci8086,340b at 4/pci1028,1f10 at 0 (mpt0): , the system freezes and ony a hard-reset fixes the issue. Is there any sort of parameter to be used to minimize/avoid this issue? Machine specs : Dell R710, 16 GB memory, 2 Intel Quad-Core E5506 SunOS san01 5.11 snv_134 i86pc i386 i86pc Solaris Dell Integrated SAS 6/i Controller ( mpt0 Firmware version v0.25.47.0 (IR) ) with 2 disks attached without raid Thanks in advance, Bruno -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean.
Hi all,Yet another story regarding mpt issues, and in order to make a longstory short everytime that a Dell R710 running snv_134 logs the information scsi: [ID 107833 kern.warning] WARNING:/pci at 0,0/pci8086,340b at 4/pci1028,1f10 at 0 (mpt0): , the system freezes andony a hard-reset fixes the issue. Is there any sort of parameter to be used to minimize/avoid this issue? Machine specs : Dell R710 16 GB memory 2 Intel Quad-Core E5506 SunOS san01 5.11 snv_134 i86pc i386 i86pc Solaris Dell Integrated SAS 6/i Controller ( mpt0 Firmware version v0.25.47.0(IR) ) with 2 disks attached without raid Thanks in advance,Bruno -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean.
Bruno Sousa on Tue, Apr 27, 2010 at 09:16:08AM +0200 wrote:> Hi all, > > Yet another story regarding mpt issues, and in order to make a long > story short everytime that a Dell R710 running snv_134 logs the information > scsi: [ID 107833 kern.warning] WARNING: > /pci at 0,0/pci8086,340b at 4/pci1028,1f10 at 0 (mpt0): , the system freezes and > ony a hard-reset fixes the issue. > > Is there any sort of parameter to be used to minimize/avoid this issue? >We had the same problem on a X4600, turned out to be a bad SSD and or connection at the location listed in the error message. Since removing that drive, we have not encounted that issue. You might want to look at http://bugs.opensolaris.org/bugdatabase/view_bug.do;jsessionid=7acda35c626180d9cda7bd1df451?bug_id=6894775 too. -Mark> Machine specs : > > Dell R710, 16 GB memory, 2 Intel Quad-Core E5506 > SunOS san01 5.11 snv_134 i86pc i386 i86pc Solaris > Dell Integrated SAS 6/i Controller ( mpt0 Firmware version v0.25.47.0 > (IR) ) with 2 disks attached without raid > > > Thanks in advance, > Bruno > > > > -- > This message has been scanned for viruses and > dangerous content by MailScanner, and is > believed to be clean. > > _______________________________________________ > zfs-discuss mailing list > zfs-discuss at opensolaris.org > http://mail.opensolaris.org/mailman/listinfo/zfs-discuss
Hi Mark, I also had some SSD drives in this machine, but i have take them out but the problem still occours... Regarding the bug, well it seems to be related with usage of xVM , and since i don''t use maybe it will not make any difference to this particular server... Anyway, thanks for the tip, and i will try to understand what''s wrong with this machine. Bruno On 27-4-2010 16:41, Mark Ogden wrote:> Bruno Sousa on Tue, Apr 27, 2010 at 09:16:08AM +0200 wrote: > >> Hi all, >> >> Yet another story regarding mpt issues, and in order to make a long >> story short everytime that a Dell R710 running snv_134 logs the information >> scsi: [ID 107833 kern.warning] WARNING: >> /pci at 0,0/pci8086,340b at 4/pci1028,1f10 at 0 (mpt0): , the system freezes and >> ony a hard-reset fixes the issue. >> >> Is there any sort of parameter to be used to minimize/avoid this issue? >> >> > We had the same problem on a X4600, turned out to be a bad > SSD and or connection at the location listed in the error message. > > Since removing that drive, we have not encounted that issue. > > You might want to look at > > http://bugs.opensolaris.org/bugdatabase/view_bug.do;jsessionid=7acda35c626180d9cda7bd1df451?bug_id=6894775 too. > > > -Mark > > >> Machine specs : >> >> Dell R710, 16 GB memory, 2 Intel Quad-Core E5506 >> SunOS san01 5.11 snv_134 i86pc i386 i86pc Solaris >> Dell Integrated SAS 6/i Controller ( mpt0 Firmware version v0.25.47.0 >> (IR) ) with 2 disks attached without raid >> >> >> Thanks in advance, >> Bruno >> >> >> >> -- >> This message has been scanned for viruses and >> dangerous content by MailScanner, and is >> believed to be clean. >> >> _______________________________________________ >> zfs-discuss mailing list >> zfs-discuss at opensolaris.org >> http://mail.opensolaris.org/mailman/listinfo/zfs-discuss >> >-- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean.