similar to: AVRX750/500 issues

Displaying 20 results from an estimated 2000 matches similar to: "AVRX750/500 issues"

2020 Jul 22
3
AVRX750/500 issues
Thanks for chiming in @David Zomaya. Tripp Lite replaced my AVRX550U once thinking that the powering back on was a defective unit, but the replacement does the same thing. The SN on the first one is 2935AVHOM87BB00152. NUT has my model listed as protocol 2010, so that needs to be corrected to 2012, but I'm not sure if anyone is doing active development on it right now. I also have a
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
On Sat, Jun 27, 2020, at 23:11, Manuel Wolfshant wrote: > On 6/28/20 5:54 AM, Scott Colby wrote: >> >> I'm not convinced this is the problem; I think that pfSense has an alternative way of running the NUT components: # ps aux | grep ups root 45456 0.0 0.1 6796 884 - Is 02:22 0:00.01 /usr/local/sbin/upsmon uucp 45751 0.0 0.1 6796 772 - S 02:22
2020 Jul 24
2
OMNIVSX1000D Compatibility
David, Thank you. I created a Github issue (https://github.com/networkupstools/nut/issues/808). I don't know who monitors those tickets, but no one has responded to my previous issue on that project repository about the AVRX550U, so it's unclear if the right person is going to see this one. Can you tell me what other models use the 3024 protocol? Listing those may help provide
2020 Jul 26
3
[EXTERNAL] Re: OMNIVSX1000D Compatibility
Did you see what objecttothis posted on GitHub already? In any event, your issue with NUT and the 3024 AVR750U is that the UPS reboots output instead of shutting off when the shutdown command is sent, correct? Good suggestion on the driver authors, thanks. Thank you, David Zomaya From: Nut-upsuser <nut-upsuser-bounces+david_zomaya=tripplite.com at alioth-lists.debian.net> on
2008 Feb 20
2
MGE pulsar evolution 3000 discharges without nut noticing
I'm running nut 2.0.1 with an MGE pulsar evolution 3000 with the mge-utalk (serial) driver on NetBSD 3.1 . I had a very strange occurance in my basement datacenter this early AM. the following was logged by upslog: 20080219 023452 100.0 123.0 049.0 [OL CHRG] NA 60.00 20080219 023522 100.0 122.8 049.0 [OL CHRG] NA 60.00 20080219 023552 098.0 123.0 049.0 [OL DISCHRG] NA 60.00 20080219 023622
2005 Oct 09
1
apc-hid tests with the new ups_status updates
Peter, Here are the transitions that I have tested with your latest changes (on the APC/Back-UPS ES 650): 1) OL ==> OB DISCHRG followed by OB DISCHRG ==> OL (no CHRG inbetween) 2) OL CHRG ==> OL 3) OL CHRG ==> OL CHRG LB (by manipulating battery.charge.low) 4) OL CHRG LB ==> OL CHRG (i.e. transition from below) 5) OB DISCHRG ==> FSD OB DISCHRG LB followed by proper shutdown In
2011 Jul 21
1
Unexpected shutdown begins for WOW-500U
G'day, all! I installed latest stable nut-2.6.1.tar.gz from source on Xenserver 5.6 SP2 (Linux xen-home 2.6.32.12-0.7.1.xs5.6.100.323.170596xen #1 SMP Fri Apr 8 07:25:07 EDT 2011 i686 athlon i386 GNU/Linux), my UPS is Powercom WOW--500U FW3.A4. All works almost fine but here are some troubles: when I pull the plug then upsd immediately starts (after FINALDELAY delaying) the procedure of
2013 Jul 17
2
HP R12000/3 UPS reports status as OL DISCHRG OB
Here's the first update of ups.status: 0.102449 getting data: ups.status (.1.3.6.1.4.1.232.165.3.4.5.0) 0.102546 su_ups_get: ups.status .1.3.6.1.4.1.232.165.3.4.5.0 0.102646 nut_snmp_get(.1.3.6.1.4.1.232.165.3.4.5.0) 0.104539 SNMP UPS driver : entering su_status_set() 0.104641 su_find_infoval: found OL (value: 3) 0.104730 => value: 3 0.104823 getting data: ups.status
2020 Feb 18
2
UPS shuts down after restart
>> But I noticed two other details: >> 1. I was a bit wrong with step 7 and 8 - Looks like the UPS is "OL CHRG" (according to display) at first but goes to battery ("OL DISCHRG" according to nut) right when the RasPi (and nut) is booting. >> 2. When I pull the plug of the RasPi after UPS went down before main power comes back (so between step 5 and 6), the UPS
2013 Jul 15
4
HP R12000/3 UPS reports status as OL DISCHRG OB
Hi. Back before Christmas Arnaud sent me a patch for the snmp-ups driver for my HP R12000/3 UPS. Unfortunately shortly after I had to take quite a lot of sick leave so wasn't able to progress it, but I'm working on it again now. I'm at the point where I can start the driver with upsdrvctl and start the daemon with upsd. When I check the UPS status though it shows as OL DISCHRG OB,
2013 Jul 15
0
HP R12000/3 UPS reports status as OL DISCHRG OB
On Jul 15, 2013, at 6:17 AM, Pratt Chris wrote: > Hi. > > Back before Christmas Arnaud sent me a patch for the snmp-ups driver for my HP R12000/3 UPS. Unfortunately shortly after I had to take quite a lot of sick leave so wasn?t able to progress it, but I?m working on it again now. Hi Chris, Is this the patch you are referring to?
2013 Jul 16
0
HP R12000/3 UPS reports status as OL DISCHRG OB
Sorry about that! Chris. Chris Pratt Development Infrastructure Manager T: +44 118 929 4176 | M: +44 7979 854 307 | F: +44 118 929 4001 -----Original Message----- From: Charles Lepple [mailto:clepple at gmail.com] Sent: 16 July 2013 00:32 To: Pratt Chris Subject: Re: [Nut-upsuser] HP R12000/3 UPS reports status as OL DISCHRG OB On Jul 15, 2013, at 9:35 AM, Pratt Chris wrote: > Debug output
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Thanks for the quick response! On Sat, Jun 27, 2020, at 22:17, Manuel Wolfshant wrote: > On 6/28/20 4:25 AM, Scott Colby wrote: > > Hello, > > > > I am having difficulty using NUT to shut down my Netgate SG-1100 > > (a pfSense router) when the power level of the UPS gets critically > > low. > > > > Here is some relevant information: > > - OS:
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Hello, I am having difficulty using NUT to shut down my Netgate SG-1100 (a pfSense router) when the power level of the UPS gets critically low. Here is some relevant information: - OS: pfSense 2.4.5-RELEASE-p1 (FreeBSD 11.3-STABLE) - NUT version: 2.7.4 - Installed from: pfSense package 2.7.4_7 - UPS: AVR750U (Device release number 2) - I have included my config files, output from `upsc`, and
2016 May 13
3
Low Battery event not occurring
Hi Everyone, New to the list. Thanks in advance for any assistance you are able to provide. I have a TrippLite SMART2200RM2UN UPS. I have installed and configured NUT as instructed on the website, and am able to monitor the status of the UPS without much problem. The only problem I am seeing is that I cannot get the machine to actually send a Low Battery ( LB ) signal. When I run
2020 Jul 25
0
OMNIVSX1000D Compatibility
Hi, I can confirm that with my AVR750U connected to my Windows machine using the TrippLite Power Alert software, I can configure it to do the behavior I want: turn off at a low power level and turn back on when the power is reconnected, so I guess it's now a question of if NUT can be adapted to the 3024 protocol. I am not the most experienced C programmer out there, but given there are
2020 Feb 18
2
UPS shuts down after restart
Hi Roger, Hi all,   > Does upsmon.conf specify a shutdown on LB? I think so. You mean SHUTDOWNCMD? The relevant parts of my upsmon.conf (notifications removed): MONITOR ups at localhost 1 upsmaster secret master MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" POLLFREQ 5 POLLFREQALERT 2 HOSTSYNC 15 DEADTIME 40 POWERDOWNFLAG /etc/killpower RBWARNTIME 43200 NOCOMMWARNTIME 1800
2020 Jul 23
1
OMNIVSX1000D Compatibility
Thank you David. I think the end goal of making this UPS compatible with NUT helps both Tripp-Lite and NUT users in that greater compatibility insures more users purchase Tripp-Lite products. I do understand Tripp-Lite wanting to do their due diligence to protect IP, however, it seems like unless NUT devs can get a hold of some sort of documentation, it's more difficult to make this and
2017 May 16
2
Fw: [Nut-upsdev] POWERCOM-UPS-USB : UPS Shutdown
Good Day Roger Price AA. Hi, Normally one would expect the UPS to disconnect it's power outlets after the default ups.delay.shutdown = 20 seconds. ==> I got it. I tried to command "upsdrvctl shutdown" on both line-mode and battery-mode ==> But ups do not disconnect its outlets power ----------------------------------------------------------------------------------- BB.
2008 Oct 04
3
Bug#501087: nut: support for a tripplite avr750u
Hi Raphael, btw, are you 2 bugs today a simple coincidence with my linkedIn invitation yesterday? ;-) 2008/10/4 Raphael Geissert <atomo64 at gmail.com>: > Package: nut > Version: 2.2.2-8 > Severity: wishlist > Tags: patch > > Attached is a patch adding "support" for tripplite's avr750u UPS. > Issues: > * productid still needs to be specified in