Displaying 20 results from an estimated 1000 matches similar to: "HCL Cyberpower CPS-850AVRLCD supported by usbhid"
2017 Sep 28
1
[HCL] CyberPower EC350G supported by usbhid-ups
[shutdown sequence]
I have tested and verified the shutdown sequence works.
[manufacturor]
https://www.cyberpowersystems.com/product/ups/ec350g/
mbeisser at nas:~$ upsc ups
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1575
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 9.3
2012 Feb 22
1
[HCL] CyberPower OR700 supported by usbhid-ups
CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html)
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 6000
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 14.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS OR700
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
CyberPower Battery Backup with Surge Protection, model LE825G
Appears to function properly with the driver listed on the HCL for the
Cyber Power Systems ups 2 685AVR USB (usbhid-ups).
Tested with shutdown mode "UPS Goes On Battery" with a 5 second timer
and the system successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
2012 Apr 26
1
[HCL] CyberPower Systems PR6000LCDRTXL5U supported by usbhid-ups
CyberPower Systems PR6000LCDRTXL5U
http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/pp-series/PR6000LCDRTXL5U.html
I had to create the following udev rule (on RHEL6):
ATTR{idVendor}=="0764", ATTR{idProduct}=="0601", MODE="664", GROUP="dialout"
Shutdown testing successful. UPS comes back online after turning off.
# upsc
battery.charge:
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
Cyber Power Systems CP600LCD
https://www.cyberpowersystems.com/product/ups/cp600lcd/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP600
device.type: ups
driver.name: usbhid-ups
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U
https://www.cyberpowersystems.com/product/ups/avrg750u/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 15360
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: AVRG750U
device.serial: <REDACTED>
device.type: ups
2012 May 28
1
[HCL] Cyber Power Systems CP1000PFCLCD supported by usbhid-ups
Cyber Power Systems CP1000PFCLCD
= upsc output =
attached
= Shutdown results =
I experienced a genuine power outage shortly after setup. The 1 master
system and the 1 slave system both shutdown successfully. The master
shutdown before the slave (*not* a bug report; I may not have this
configured correctly yet). The UPS was not powered off by the master. I
don't know if the UPS
2016 Dec 08
2
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
I didn't want to sign up for the nut-devs list or create a git account
just to provide this information, so I hope posting this info here is OK...
I just bought a Cyber Power Systems EC750G UPS for use as a spare. Here
are some info for it:
=========================
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime:
2012 Aug 30
2
UPS - CYBERPOWER CPS DX600E supported by usbhid-ups
UPS - CYBERPOWER CPS DX600E
upsc usb at localhost
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1650
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 4.8
battery.voltage.nominal: 12
device.mfr: CPS
device.model: DX600E
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2015 Feb 06
0
[HCL] <CyberPower> <Value 1500ELCD-RU> supported by <usbhid-ups>
CyberPower Value 1500ELCD-RU
root at ubuntu:/home/oper# upsc myups at localhost
battery.charge: 87
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 5220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 16.5
battery.voltage.nominal: 24
device.mfr: CPS
device.model: Value1500E
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq:
2006 May 07
3
Yet another HID device - Cyberpower AE550
Hope it's not too rude to just drop this here for y'all...
Checking device (0764/0501) (001/005)
- VendorID: 0764
- ProductID: 0501
- Manufacturer: CPS
- Product: UPS AE550
- Serial Number: unknown
This one and their 485 don't provide a load measurement -- the Windows drivers kick it onto battery for a timed period and measure the drain to guess the runtime -- apparently all their
2016 Nov 23
2
[HCL] CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups
It looks like the CyberPower Cyber Power Systems CP685AVR supported by
usbhid-ups has a favorable device dump linked to the Devices Dumps
Library page here:
http://networkupstools.org/ddl/Cyber_Power_Systems/CP685AVR.html
However, it is not listed anywhere on the Hardware Compatibility List
(HCL) page here:
http://networkupstools.org/stable-hcl.html
This appears to be an omission on the HCL
2019 Feb 16
2
why did self test warn?
The battery was replaced in December and the output from upsc was:
$ upsc desktop_ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1020
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP850AVRLCD
device.type: ups
driver.name: usbhid-ups
2020 Oct 26
0
Can't get CyberPower UPS to work with Raspberry Pi 4
On Oct 25, 2020, at 11:52 AM, Robert Stocker <kneadtoknow at gmail.com> wrote:
>
> Init SSL without certificate database
> battery.charge: 100
> battery.charge.low: 10
> battery.charge.warning: 20
> battery.mfr.date: CPS
> battery.runtime: 15690
> battery.runtime.low: 300
> battery.type: PbAcid
> battery.voltage: 24.0
> battery.voltage.nominal: 24
I
2016 Nov 24
0
[HCL] CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups
[please use Reply-All - this list does not modify the reply-to header]
> On Nov 23, 2016, at 10:30 AM, Craig STCR <craig.stcr1 at gmail.com> wrote:
>
> It looks like the CyberPower Cyber Power Systems CP685AVR supported by
> usbhid-ups has a favorable device dump linked to the Devices Dumps
> Library page here:
>
>
2012 Aug 13
1
FreeBSD + nut usbhid-ups
hi.
why choose 1.4? correctly 1.3
FreeBSD hq.local 9.1-PRERELEASE FreeBSD 9.1-PRERELEASE #1: Tue Jul 31
19:48:36 MSK 2012 root at hq.local:/sys/amd64/compile/HQ amd64
ugen1.3: <DELL> at usbus1
uhid0: <DELL Dell UPS Rack 1920W HV, class 0/0, rev 1.10/1.00, addr 3> on usbus1
root at hq: # usbconfig
ugen0.1: <EHCI root HUB Intel> at usbus0, cfg=0 md=HOST spd=HIGH
(480Mbps)
2018 Dec 16
1
detailed ups.test.result
On 2018-12-16 8:04 a.m., Charles Lepple wrote:
> On Dec 15, 2018, at 10:32 PM, James <bjlockie at lockie.ca> wrote:
>>
>> My UPS has an LCD that says the battery is 100% and the estimated run time is 12min.
>> The uspc has similar results.
>> The problem is when line power is lost the UPS batter goes to 0% very quickly (seconds).
>>
>> It charged to 85%
2024 Apr 23
1
CyberPower CST150UC: Question re: battery.runtime.low configuration settings
I would like to solicit some feedback re: the
battery.runtime.lowconfiguration settings through NUT. I was able to set
the value using the 'upsrw' command but when I did a 'upsc' the
configuration seems incorrect. Please see below for details. Thank you
OS name and version:
?? ?Description:??? Debian GNU/Linux 12 (bookworm)
?? ?Release:??????? 12
?? ?Codename:?????? bookworm
2019 Apr 03
2
variables between manufacturers
I switched my desktop with my raspberry pi because I thought my desktop
ups had a larger capacity.
Now the ups.load of each is not what it was (it should be).
The battery.runtime is better for my desktop (it's supposed to be worse)
and my raspberry pi is worse (I hoped for hours better).
What am I seeing?
I switched them for longer raspberry pi time and the APC battery is
getting old. :-)
2024 Dec 04
1
<Cyber Energy> <usbhid-ups/cps-hid.c>-Add HID Usage (Temperature)
Hi NUT:
We propose adding HID usage for "Temperature" to the NUT source code file cps-hid.c (driver: USBHID-UPS(8)<https://networkupstools.org/docs/man/usbhid-ups.html>) so that UPS temperature information can be displayed in the UPS status list. After conducting internal tests, we confirmed that inserting the following code:
{ "ups.temperature", 0, 0,