[Nut-upsdev] [HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U https://www.cyberpowersystems.com/product/ups/avrg750u/ upsc output: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 15360 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 24.0 battery.voltage.nominal: 24 device.mfr: CPS device.model: AVRG750U device.serial: <REDACTED> device.type: ups driver.name: usbhid-ups driver.parameter.offdelay: 60 driver.parameter.ondelay: 120 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 15 driver.parameter.port: auto driver.parameter.productid: 0501 driver.parameter.synchronous: no driver.parameter.vendorid: 0764 driver.version: 2.7.4 driver.version.data: CyberPower HID 0.4 driver.version.internal: 0.41 input.voltage: 121.0 input.voltage.nominal: 120 output.voltage: 129.0 ups.beeper.status: enabled ups.delay.shutdown: 60 ups.delay.start: 120 ups.load: 2 ups.mfr: CPS ups.model: AVRG750U ups.productid: 0501 ups.realpower.nominal: 450 ups.serial: <REDACTED> ups.status: OL ups.test.result: Done and passed ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 upsrw output: [battery.charge.low] Remaining battery level when UPS switches to LB (percent) Type: STRING Maximum length: 10 Value: 10 [battery.runtime.low] Remaining battery runtime when UPS switches to LB (seconds) Type: STRING Maximum length: 10 Value: 300 [ups.delay.shutdown] Interval to wait after shutdown with delay command (seconds) Type: STRING Maximum length: 10 Value: 120 [ups.delay.start] Interval to wait before (re)starting the load (seconds) Type: STRING Maximum length: 10 Value: 180 upscmd output: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a delay (seconds) load.on - Turn on the load immediately load.on.delay - Turn on the load with a delay (seconds) shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress test.battery.start.deep - Start a deep battery test test.battery.start.quick - Start a quick battery test test.battery.stop - Stop the battery test I have tested the shutdown sequence, and this device is affected by the Cyber Power Systems ondelay/offdelay bug, but otherwise, the sequence works to turn the power off, then back on when it detects line power. Cheers, X -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20180926/82a54d29/attachment.html>
Seemingly Similar Threads
- [HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
- [HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
- [HCL] Cyber Power Systems EC750G supported by usbhid-ups
- [HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
- [HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver