Displaying 20 results from an estimated 10000 matches similar to: "Question about recycle power of Tripp Lite UPS"
2014 Jun 18
2
Question about recycle power of Tripp Lite UPS
Hello Charles,
Thank you for your comment. Just tried to use ups.delay.shutdown to
postpone the UPS shutdown. The thing is that if the PC shutdown first, then
the UPS, it wasn't able to send "shutdown.reboot" any more because
everything is power off after the UPS shuts down.
Also play on the watchdog for Tripp Lite. Looks like it has the command of
reset.watchdog but not
2014 Jun 18
0
Question about recycle power of Tripp Lite UPS
[moving this to nut-upsuser, since other users of Tripp Lite equipment may have specific experience with this.]
On Jun 17, 2014, at 7:51 PM, Shen Chuan <shen at minutekey.com> wrote:
> We are trying to develop a mechanism to power cycle Tripp Lite UPS. When we checked the upscmd, looks like the only command we can use is shutdown.reboot(sudo upscmd -u user -p password ups
2018 Jan 12
2
Tripp-Lite BCPERS450 shutdown/restart problems
From: Charles Lepple <clepple at gmail.com>
Date: Thu, 11 Jan 2018 22:31:54 -0500
The trick will be adding support for this without breaking other
models.
For whatever it's worth, Tripp lite's software does not display the
model number anywhere, so it may be treating all models the same.
In case you are interested, this mapping between the "Path" and the
2018 Jan 11
2
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks again for your help, Charles. I was able to install the Tripp
Lite software on my Ubuntu machine, and it sort of works. It does
something which continually changes the USB device ID of the UPS, and
prints voluminous error messages in the log. However, one of the things
that it can do is to schedule a UPS shutdown, which Nut does not know
how to do.
So I monitored the USB port with
2013 Aug 07
2
[HCL] Tripp Lite SMART1300LCDT supported by usbhid-ups
Tripp Lite SMART1300LCDT
# upsc ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 30
battery.runtime: 2951
battery.type: PbAC
battery.voltage: 0.0
battery.voltage.nominal: 24.0
device.mfr: Tripp Lite
device.model: TRIPP LITE UPS
device.serial: 2250AVLSM872100251
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2020 May 15
4
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
Hi,
This is a newbie post so please bear with me.
After loosing my router to a random Subminute outage. I looked around
for a fanless UPS and bought Tripp Lite SMX1000LCD
The above constellation works. But I have some questions about outputs.
Please see attache nut report for the config.
upsc output:
--8<--
fourpi01:~# upsc tripp
Init SSL without certificate database
battery.charge: 100
2020 Jan 04
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
After a quick glance, it looks like that older version of the INTERNET750U supports only a few controls Shutdown of the inverter, cancelling that shutdown, setting the delay for the shutdown timer, and enabling/disabling a USB watchdog function.
My *guess* is that Network UPS Tools is just exposing the shutdown command as one command.
Does that help?
Note to users with the same model but
2020 Jan 01
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
When running 'sudo upsmon -c fsd' UPS turns off then back on after a delay
as expected. But when power is disconnected and the command is ran, the UPS
turns off but still turns back on again.
Changing 'ondelay' to -1 or 0 does not change the behavior.
How can I get the UPS load to stay turned off if there is no power? Or am I
misunderstanding how to test this functionality?
2020 Jan 01
2
[EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Hello List, David: I’ thanking you … :-)
I’m using the tripplite_usb driver and the barcode on mine says: 9347AIOBC470902728 or 9347A10BC470902728.
with pictures…
https://drive.google.com/file/d/1SJWDr0g95KOD-FpbOPHUyl9bsbOKePlD/view?usp=sharing
https://drive.google.com/file/d/1SFMT-GbZRcRO03gEy_7SszZ43-LYmEZM/view?usp=sharing
2015 Jan 10
1
libusb drops connection to my Tripp Lite SMART500T1U
On Thu, Jan 8, 2015 at 11:37 PM, Charles Lepple <clepple at gmail.com> wrote:
> Although this tends to happen more with x86 systems and/or USB3, you might want to see if the disconnects are less frequent with a shorter or higher-quality USB cable.
The more I look into this ... the more I think that it's exclusively
Tripp-Lite weirdness! There are some things that I explored as far
2020 Jan 04
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Hi Jean-Roch,
No. There is no user-facing firmware update process available.
If there are any particular commands you're interested in on a newer unit, I can look them up.
________________________________
From: jean-roch blais <blaisjeanroch at gmail.com>
Sent: Friday, January 3, 2020 6:13 PM
To: David Zomaya
Cc: nut-upsuser at alioth-lists.debian.net
Subject: Re: [POSSIBLE FRAUD] Re:
2020 Apr 28
2
Tripp-Lite SMART1500LCD: powers off with /etc/killpower...then powers back on...
Hi Everyone,
I recently bought a Tripp-Lite SMART1500LCD for my Linux Mint 19.3 machine,
connected via a USB cable. I installed Nut 2.7.4 from the Mint package
repository via sudo apt update && sudo apt install nut. Everything works
great: NUT issues low battery warning when it reaches the set low
battery point and then issues shutdown commands...computer shuts
down..then the UPS shuts
2006 Aug 08
0
Re: Tripp Lite LCD models w/ NUT
Hi James,
thanks for the feedback. The output you get seems generally fine,
except for battery.voltage: 0.0 and output.voltage: 164.0; these
values are consistent with what Phil DeBoest reported.
Upsmon normally executes the shutdown command when you reach the "low
battery" threshold, as decided by the UPS and/or driver. It does so by
looking at ups.status, not battery.charge.
--
2007 Jan 10
1
Tripp Lite OMNI1000LCD UPS (USB)
Hello NUT-UPSUSERS,
I would just like to try and help other and indicate that I was able to use
the development trunk and get the Tripp Lite OMNI1000LCD UPS (USB) working
with the newhidups drivers on Gentoo Linux. The one that is currently
available at many local Costco stores and online.
In case others need to replicate, I've attempted to document my steps over
here.
2013 Oct 30
2
UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
Hello Mr. Leppe,
See the attached excel file that covers the current Tripp Lite HID compatible UPS systems. There is also an attached Word document covering the UPSC / UPSCMD / UPSRW information from the specific UPS systems. Let me know if this is adequate to get our additional HID compatible products added to the NUT HCL listing.
Tripp Lite
Eric K. Cobb
Product Management Specialist
1111
2020 Jan 14
2
[EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
If you'd like, shoot me over your serial number and the corner-cases you don't have answers for and I can look into it.
Thank you,
David Zomaya
Tripp Lite
david_zomaya at tripplite.com
-----Original Message-----
From: Nut-upsuser <nut-upsuser-bounces+david_zomaya=tripplite.com at alioth-lists.debian.net> On Behalf Of Ken Olum
Sent: Tuesday, January 14, 2020 11:24 AM
To: Layne
2012 Feb 13
1
[HCL] Tripp-Lite Omnismart500 supported by tripplite_usb
Device manufacturer and name:
Tripp-Lite OmniSmart500
upsc output:
matt at backup:/etc$ sudo upsc tripplite
battery.charge: 100
battery.test.status: Battery OK
battery.voltage: 14.56
battery.voltage.nominal: 12
device.mfr: Tripp Lite
device.model: OMNISMART500
device.type: ups
driver.name: tripplite_usb
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version: 2.4.3
2020 May 20
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
Tested a Ubuntu 18.04 LTS virtual machine with NUT 2.7.4 and a 3024 protocol Tripp Lite UPS (mine is a INTERNET550U, but same protocol)
:/etc/nut$ lsusb | grep Tripp
Bus 002 Device 004: ID 09ae:3024 Tripp Lite
I it got generally working (outputting reasonable responses to upsc, although there are some issues with variables like frequency) by adding productid=3024 to my ups.conf. Like this:
2018 Jan 23
2
Tripp-Lite BCPERS450 shutdown/restart problems
On Jan 22, 2018, at 3:00 PM, Ken Olum <kdo at cosmos.phy.tufts.edu> wrote:
>
> I tested the effect of setting UPS.OutletSystem.Outlet.DelayBeforeShutdown
> using Tripp Lite's software, which appears to be as follows:
>
Theoretically, this should be the same as running the command "upscmd bcpers at localhost -u <upsd.user> load.off.delay <delay>".
>
2020 Jan 14
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
Your suggestion of rebuilding the driver fixed the issue of the UPS turning
back during a power failure. Now the UPS shuts down the clients, then
powers off appropriately. If power returns it turns back on also.
The only bug is if power returns before the UPS has turned the load off. In
that case the UPS will remain off until it is manually turned on.
This might just be a limitation of this