similar to: Powercom BNT-1000CS

Displaying 20 results from an estimated 2000 matches similar to: "Powercom BNT-1000CS"

2013 May 01
1
Powercom BNT-1500AP serial config
Hey all, Finally got around to hooking up my Powercom BNT-1500AP to nut. It's the old serial interface. Connects okay and gets most information, but a couple of data are way off. Any config recommendations or upgrade recommended? I've played with config a little, but no hits yet. Details: NUT version 2.4.3 ups.conf: [ups] driver = powercom port = /dev/ttyS0
2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all. Try this driver (for nut 2.2.0). See attach. - Trust, KP625AP, Egys models stay as it was - add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP 220-240V ) - add Powercom's King Pro model support ( KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V) - add Powercom's Imperial model support ( IMP-xxxAP,
2006 Apr 21
1
Powercom BNT-1200AP
Hello I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP) I try to use nut, but powercom driver not understand my model Ok, i try to use type KIN1500AP and it's work But powercom driver can't set UPS's shutdown delay time Also i have powercom's original program (upsmon), and this program can do it What can i do for help to add this function to nut's powercom driver? For
2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
Hello. I've been trying to got it work but haven't luck. I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed (USB\VID_0D9F&PID_0004&REV_0001). I had tryed all options with such config: *PWCOM] driver = usbhid-ups port = auto vendorid = 0d9f desc = "Powercom BNT-800AP" type=BNT* * *Here is output from CMD:*
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
Good afternoon. I try to put nut on gentoo. Has executed installation by a standard command emerge nut. All has passed successfully. I use UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my system it/dev/tts/0. In/etc/nut/ups.conf [powercom] driver = powercom port = /dev/tts/0 desc = "PowerCom BNT-1500AP on IP-PBX" modelname = "BNT-1500AP" linevoltage = 230
2006 Dec 22
1
Powercom BNT-1200AP driver
Hello. What about driver for my UPS? I have changed the powercom driver for myself, but I have made it not absolutely correctly. However, somehow this driver works. Now i have protocol spec for powercom BNT series and attach it to this email. It can be interesting to authors? -- ? ?????????, ??????? ??????? mailto:alex@reutman.ru JID: alex@reutman.ru ICQ: 5052225 -------------- next part
2017 Apr 28
3
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent four last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2007 Nov 06
1
BNT-1000AP
Hi guys, We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the KIN1500AP model in the powercom driver. Well, almost. It seems the input frequency and the battery charge is swapped around: # upsc blackknight at localhost battery.charge: 46.5 driver.name: powercom driver.parameter.manufacturer: BlackKnight driver.parameter.modelname: BNT-1000AP driver.parameter.port:
2009 Sep 19
1
Powercom 600AP USB support
Hi, I know it's been a topic many times here, but I've searched the archives, googled for days, and I simply don't believe, that there is still no solution to this. I'm using a PowerCom BNT-600AP ups with usb port. I've downloaded the latest version from svn, compiled it, and tried to use it: * megatec(_usb) - no luck, it did not find the UPS (I?ve read in this list, that
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people, I use a BNT-600AP from PowerCom, and on driver loading (nut service start) the UPS goes off so I cannot use nut as service as the computer goes off with the UPS. When the computer is not using the UPS, but still connected, I see that the UPS goes off for a very short time, does battery check and goes on again. I don't know how to deal with this issue as I cannot use my UPS
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
Dino, Alexey, there are a number of users suffering issues with your Powercom devices. Could you (Dino, and Keven if possible) please have a look at the below one, from Angela, and check for a fix? I've scheduled to release 2.6.1 next week, and having that fixed is part of the list. 2011/5/16 Angela Williams <angierfw at gmail.com> > Hi All > > On Friday 13 May 2011 at
2014 Jul 25
3
POWERCOM HID USB controller update
Dear Sirs, First of all I would like to thank you for support PCM product in your project. Kindly please be informed that POWERCOM launch new USB-controller with productID 0X04. Updated USB-controller compatible with previous version which supported by your usbhid-ups driver. There is added some command and changed idProduct. Vendor ID stay the same 0X0d9f without changes. Detailed information
2014 Sep 11
0
POWERCOM HID USB controller update
Dear Sirs, We appreciate your support and cooperation. Can you please kindly add our new USB-controller with productID 0X04 to NUT compatible list. Updated USB-controller compatible with previous version which is supported by your usbhid-ups driver. Detailed information regarding new POWERCOM communication protocol you could download via link
2013 Jun 08
2
several problems with Powercom BNT-500AP
Thanks for the support. Here's list of when transition to battery with return to utility power within a few seconds occurred in last few days: Wednesday 1:41 11:48 11:54 12:59 13:42 14:42 18:13 18:14 Thursday 5:23 Friday 5:12 7:39 7:43 Saturday 7:34 Here's list of when messages that battery needs replacement occurred: Wednesday 20:34 Thursday 9:07 23:09 Friday 18:25 Saturday 7:32 19:47
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
Hi! Normally nut was just worked and worked for me! Not this time though! Distro is Gentoo withe latest nut-2.6.0 emerged today. Linux kernel version is 2.6.36 UPS is PowerCom BNT2000AT "Driver" is powercom ups.conf looks like this! Okay so APC1 is not and APC! [APC1] driver = powercom type = BNT port = /dev/ttyS1 numOfBytesFromUPS = 16
2011 Jan 13
0
[NUT]updated powercom driver for powercom BNT-500AP
Hi, 2010/12/27 ??? <pointbre at naver.com> > First of all, thanks for your effort to NUT Project, > I'm developing remote monitoring solution for many devices based on linux > server. > In field test, we reached the power shutdown problem which may cause the > crack of linux file system. > I search the solution and find NUT project and i'm very glad that NUT >
2005 Jul 06
0
Powercom BNT-1500AP
Hey all, Does anybody know there is a full working setup for the PowerCom BNT-1500AP. I got some stuff working with the Powercom driver and the type set to "KIN1500AP". But it seems that there is still missing usablity. I was wondering if anybody found any better configs? ---- excerpt of ups.conf [AVR1500] driver = powercom port = /dev/ttyS0 desc =
2017 Apr 26
0
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent three last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2013 Jun 10
2
several problems with Powercom BNT-500AP
I took the log. Here's what happened. Broadcast Message from nut at rasp (somewhere) at 16:18 ... UPS BNT500AP at localhost battery needs to be replaced occurred when for the first time value "1" was read as "UPS.PowerSummary.PresentStatus.NeedReplacement", on this line: 6409.240690 Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID: 0x0a,
2011 Apr 28
2
PowerCOM Driver Update
I and several other users have encountered problems using PowerCOM UPS of the BNT 1500A model. Looking over other responses and dealing with my own issues, I submit the following attached patch. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20110428/00d7d2f9/attachment.htm> -------------- next