2005 Oct 02
0
2.0.3-pre
Gentlemen,
I just had time to start looking at the latest version of the development
tree. I have built the apc-hid part of newhidups from the development tree
and I am in the process of testing it with my "Back-UPS ES 650".
As of right now I have incorporated the attached changes to apc-hid.c.
I have been using the corresponding changes together with some changes
from Arnaud with the
2005 Oct 02
3
more on 2.0.3-pre
Gentlemen,
I have now had a chance to run some initial tests of my changes to
apc-hid.c of the current development tree. Running newhipups and
inspecting the -DDDD output seems to indicate that with the fix below
everything seems to work as expected. However, I have not yet shut
my system in order to take the UPS out of action so that I can do my
various tests with a lightbulb load. I still hope
2005 Aug 04
1
a patch for apc-hid.h
Gentlemen,
I have determined that on my UPS (APC Back-UPS ES 650 FW:818.w1.D USB FW:w1),
the variable UPS.PowerSummary.RemainingCapacityLimit is writeable. I am
setting this variable to start shutdown a little earlier. Appended is an
unconditional patch for apc-hid.h.
If, as indicated by the original code, there are APC UPS devices that don't
allow setting of this variable, it becomes
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi,
This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status.
Details of our installation are:
OS: Debian 6
NUT version: 2.7.4
Installation method: from source tarball
UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in
2008 Feb 24
2
usbhid-ups using wrong value for battery voltage for Pulsar Evolution 500?
I suspect that the battery is failing on my Pulsar Evolution 500 (it
is several years old now) but I can't seem to get a valid battery
voltage from the UPS.
The following tests were done using NUT 2.2.1, but I first noticed
this with the trunk, and reproduced it with the current
branches/Testing as well.
The only two values I have seen for battery.voltage are 120.0 and 119.0, e.g.:
$ upsc
2008 Dec 31
2
Unknown product ID for Tripp-Lite UPS (SU1500RTXL2UA)
To all,
I attempted to configure the UPS tools for the Tripp-Lite SmartOnline 1500VA 2U rackmount UPS. I followed the instructions from the 'upsdrvctl start' output and posted the diagnostic information below.
Is my UPS using an unknown product ID as reported? From the mailing list archive, I have found another posting for the same UPS with device model '09AE/4003', whereas
2020 Jan 01
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
When running 'sudo upsmon -c fsd' UPS turns off then back on after a delay
as expected. But when power is disconnected and the command is ran, the UPS
turns off but still turns back on again.
Changing 'ondelay' to -1 or 0 does not change the behavior.
How can I get the UPS load to stay turned off if there is no power? Or am I
misunderstanding how to test this functionality?
2013 Aug 07
4
HP R1500 G3 problems
Hi there,
OS: (L)ubuntu 12.04 precise LTS
Nut: 2.6.3-1ubuntu1.1
Installation Method: Package (apt-get install nut)
Hardware: HP R1500 G3 INT
Hardware-Specs:
http://h18004.www1.hp.com/products/quickspecs/14059_div/14059_div.pdf
Problem:
I tried to set up nut with our new arrived HP R1500 G3 UPS but there is
a failure with the usb connection. After trying "/lib/nut/usbhid-ups -DD
-a
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help.
From: Charles Lepple <clepple at gmail.com>
Date: Mon, 18 Dec 2017 19:26:56 -0500
This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally:
What was the largest
2020 Jun 28
0
AVR750U Low Power not Triggering Shutdown
On 6/28/20 4:25 AM, Scott Colby wrote:
> Hello,
>
> I am having difficulty using NUT to shut down my Netgate SG-1100
> (a pfSense router) when the power level of the UPS gets critically
> low.
>
> Here is some relevant information:
> - OS: pfSense 2.4.5-RELEASE-p1 (FreeBSD 11.3-STABLE)
> - NUT version: 2.7.4
> - Installed from: pfSense package 2.7.4_7
> - UPS:
2007 Dec 05
2
Crash when I start driver
It's been a while since I tried to use NUT, so I thought I would give it
another try. Big trouble.
The UPS is a Tripp-Lite AVR 550U. It has only a USB connector.
The computer is running Red Hat Enterprise Linux 4.
I just installed NUT version 2.2.0. I'm going through the steps in
the INSTALL document.
# cat ups.conf
[igor]
driver = usbhid-ups
port = auto
2008 Mar 03
1
Tripplite Smart1000LCD problem with revision > r1071
Hi,
With recent revision, it's impossible to get upsdrvctl started:
[root at teevee nut]# /usr/local/bin/upsdrvctl start
Network UPS Tools - UPS driver controller 2.3.0-1352
Network UPS Tools: 0.29 USB communication driver - core 0.33 (2.3.0-1352)
Warning: This is an experimental driver.
Some features may not function correctly.
Using subdriver: TrippLite HID 0.2 (experimental)
2010 Feb 18
2
HP R1500 G2 UPS
Hi,
I have a HP R1500 G2 UPS and want to get it working under Debian Lenny - as this OS is not supported by HP I'm
trying to use nut for it - but I can't get it working.
Do I have any chance to get the UPS running with nut. I also tried different drivers but had no luck either.
Or does anyone has experience with HP UPS under debian ?
Any help would be nice !
I tried
/lib/nut/usbhid-ups
2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
I have a Tripp-Lite BCPERS450, connected to a system running Ubuntu
16.04.3 LTS and NUT 2.7.2-4ubuntu1.2. I had to make my own
/lib/systemd/system-shutdown/nutshutdown, but now everything is working
except for powering on and off the UPS. Regardless of the settings of
offdelay and ondelay in upsconf, and regardless of whether the AC power
is on, when I say "upsdrvctl shutdown" the UPS
2006 Nov 15
1
Tripp Lite OMNI900LCD
I am having an issue running NUT and using an TrippLite OMNI900LCD.
When I run ./upsdrvctl start I get :
[player@V0002-S002 bin]$./upsdrvctl start
Network UPS Tools - UPS driver controller 2.1.0
Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 (2.1.0)
Detected a UPS: Tripp Lite /TRIPP LITE UPS
Using subdriver: TrippLite HID 0.1 (experimental)
dstate_setflags: base variable
2019 Dec 08
3
Tripp Lite SMART1500LCD repeatedly disconnecting and reconnecting
My UPS is connected to a Raspberry Pi by USB. After a few hours of working,
the service fails. Looking at kernel messages I noticed that the device is
repeatedly disconnecting and reconnecting.
I have tried using a different USB port and using a brand new USB cable. I
have not had success by changing config parameters like
pollfreq/pollinterval/etc.
What is causing the UPS to keep disconnecting?
2018 May 25
1
[HCL] IBM 1500VA/1000W Tower HV UPS supported by usbhid-ups
Hi I would like to be able to use this UPS with NUT please ?
Product id = 53962KX
Network UPS Tools - Generic HID driver 0.38 (2.7.2)
USB communication driver 0.32
0.000000 debug level is '2'
0.002761 upsdrv_initups...
0.014996 Checking device (03F0/0024) (001/005)
0.032670 - VendorID: 03f0
0.032790 - ProductID: 0024
0.032955 - Manufacturer:
2008 Jan 26
1
USBDEVFS_CONTROL error ?
Does the following error message have a specific meaning:
usb 1-1: usbfs: USBDEVFS_CONTROL failed cmd usbhid-ups rqt 161 rq 1 len 2 ret -75
I get two of these messages every time I run the following:
/lib/nut/usbhid-ups -u root -DDD -a trippy
The following is the output from the above command:
debug level is '3'
Checking device (0000/0000) (004/001)
- VendorID: 0000
- ProductID:
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Thanks for the quick response!
On Sat, Jun 27, 2020, at 22:17, Manuel Wolfshant wrote:
> On 6/28/20 4:25 AM, Scott Colby wrote:
> > Hello,
> >
> > I am having difficulty using NUT to shut down my Netgate SG-1100
> > (a pfSense router) when the power level of the UPS gets critically
> > low.
> >
> > Here is some relevant information:
> > - OS:
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Hello,
I am having difficulty using NUT to shut down my Netgate SG-1100
(a pfSense router) when the power level of the UPS gets critically
low.
Here is some relevant information:
- OS: pfSense 2.4.5-RELEASE-p1 (FreeBSD 11.3-STABLE)
- NUT version: 2.7.4
- Installed from: pfSense package 2.7.4_7
- UPS: AVR750U (Device release number 2)
- I have included my config files, output from `upsc`, and