Displaying 20 results from an estimated 1100 matches similar to: "E100P and Colt Telecom (Europe)"
2003 Oct 13
2
e100p in norway?
hi
see below's conversation. it seems the e100p card doesn't work with BT.
Any idea how this'll work against Telenor (norway)?
roy
<RoyK> does anyone know if I can trust the E100P to do full PRI stuff in
.no?
<cypromis> dunno about no
<cypromis> I cannot use it in UK
<cypromis> cause the framer has problems with system-x switches at bt
2004 Oct 02
2
Billing Applications - When does the bill start??
Hi,
I have been having a look at the code for
asteriskprepaid and it appears as if the billing time
starts when the Dial command is called.
Is this correct? Does the caller get billed for the
dialling time and the call time or just the call time?
Although going off some comercial calling cards I have
used I think they start billing when you begin
thinking about the call.
Thanks,
Aaron
2003 Jul 11
2
Wildcard E100P resellers in Europe ?
All,
I'd like to buy an E100P Wildcard frm Digium, but i prefer to buy it
in Europe (costs, ...).
Could somebody point me to an european reseller ?
Thanks in advance.
--
Nicolas Cartron
nc@ncartron.org
2004 Sep 03
5
Digium E100P and PMX in Germany
Hello ml,
i need some help on my zaptel configuration. My E100P only shows some
YELLOW / RED alarm when I load the wct1xxp module and do a
cat /proc/zaptel/1
Span 1: WCT1/0 "Digium Wildcard E100P E1/PRA Card 0" HDB3/CCS YELLOW RED
...
..
.
My /etc/zaptel.conf is:
span=1,1,0,ccs,hdb3
bchan=1-15,17-31
dchan=16
loadzone=nl
defaultzone=nl
I tried zaptel-1.0RC2 and the latest CVS
2003 Dec 30
2
E100P configuration
Hi !
I am trying to configure two E100P cards, but I am a bit confused with
zapta.conf in what I am trying to achieve.
The * will be connected to a pstn switch with two E1 PRI lines. The E1 lines
will be used for incoming calls as well as outgoing calls.
My problem now is what to put in zapta.conf, I would like to group all
channels from both cards together (if that's possible). Does this
2004 Nov 23
1
Error when install E100P
Hi, all
I am trying to install E100P card, the 'modprobe zaptel' is ok, but
when I did 'modprobe wct1xxp', I got such error, so can not load the
driver for the card.
/lib/modules/2.4.20-8/misc/wct1xxp.o: init_module: No such device
Hint: insmod errors can be caused by incorrect module parameters,
including invalid IO or IRQ parameters.
You may find more information in syslog
2003 Oct 09
2
E100P setup in Switzerland
Hi all,
I am trying to setup an E100P for use on Swisscom E1-PRI here in
Switzerland.
Swisscom seems to use Siemens hardware.
Here are my configs (cvs from a few hours ago) :
zaptel.conf
loadzone=fr ; tried "de" but got warning at modprobe
defaultzone=fr
span=1,1,0,cas,hdb3,crc4,yellow ; Seems to be right, as the Siemens
SDSL-G703 modem switches its LEDs off ... not sure
2004 Jun 14
3
No B-Channels. PRI. E100P. HELP!
Hi.
I still hace problems getting my line to work. When I
start asterisk, I can see:
== Parsing '/etc/asterisk/zapata.conf': Found
-- Registered channel 1, PRI Signalling signalling
...
-- Registered channel 31, PRI Signalling signalling
== Starting D-Channel on span 1
== Registered channel type 'Zap' (Zapata Telephony
2004 Jul 06
1
zaphfc 2 cards working with P2P Mode ?? - massive Problems
Hello List,
is someone operating a DID /P2P / Anlagenanschluss with more than one
HFC-Based ISDN-Card ???
I have now 12 hours of setup-troubles behind me with Colt-Telekom, where
we did not get it working with two HFC-based cards.
Here the setup:
- 2 HFC-ISDN-Cards (the one from Conrad-Electronic)
- bri-stuff.0.0.2 (with the asterisk-sources from the
download.sh-skript)
- two NTBAs from
2003 Jul 11
7
ISDN PRI E1 configuration with E100P
<P>hi Everyone,</P>
<P>We are configuring an ISDN PRI E1 with an E100P card, when you load the drivers, and starts the asterisk, cards also starts fine, givin following output,</P>
<P>*CLI> <BR> == D-Channel on span 1 up<BR> -- B-channel 1 successfully restarted on span 1<BR> --
2006 May 11
1
Asterisk TAPI - Outlook click2dial
Yes, I have the exact same problem.
:(
-----Original Message-----
From: Tomislav Vojvodic [mailto:tomislav@vox-mundi.net]
Sent: Thursday, May 11, 2006 5:48 AM
To: xytek@hotmail.com; 'Asterisk Users Mailing List - Non-Commercial
Discussion'
Subject: RE: [Asterisk-Users] Asterisk TAPI - Outlook click2dial
Hey, thanks for your reply.. ;)
I'm also using asttapi from website you posted
2003 Jun 23
1
Setting up the E100P
Hello,
I have an E100P, and in the zaptel.conf I have:
span=1,1,0,ccs,hdb4,crc4,yellow
fxsks=1-10
the light on the card is green( BTW what do all those states of the card
that zttool reports YELLO, RED, BLUE ..., is there a doc for zttool?, or
for the card?)
in the asterisks` zapata.conf I have:
[channels]
context=default
switchtype=euroisdn
signalling=fxs_ks
usecallerid=yes
hidecallerid=no
2004 Aug 04
4
Problems with E100P
Hi,
I'm having trouble configuring and E1 link , I know the E1 is a PRI
and the switchtype is 5ess. The problem is that everytime I try to dial
I got and error saying that it was unable to open the zap channel .
Devices are created in the /dev/zap directory and I can open them with a
cat /dev/zap/1. I can also see the channels in /proc/zaptel/1.
Thanks in advance
[zaptel.conf]
2006 May 16
1
Asttapi for Asterisk 1.2 Testers Needed (was RE: Asterisk TAPI - Outlook click2dial)
I've finished a patched version of asttapi that will work with asterisk
1.2. There were fundamental changes to the Asterisk Management
interface between 1.0 and 1.2 that broke asttapi. I think my patched
version will work on 1.0 and 1.2 branches, but I have no way of testing
since I don't have a 1.0 install nor do I want one :).
I'm looking for testers, if anyone's willing to
2004 May 15
2
Subject: Re: X100P Ireland Red Alarm
Hi,
I suspected that I the analogue phone should have got
a pass through signal when the power was off to the
server, unfortunately it doesn't. I kept asking digium
support about that but they didn't give me an answer.
The problem is how do I identify whether the X100P is
incompatibel with the network or faulty without
possibly wasting another USD100???
Aaron
On Sat, 2004-05-15, Eric
2010 Aug 11
2
assignment functions with inherited class error
# Two test for a class like this:
setClass("XXX",
representation=representation(
"matrix"
)
)
i<-new("XXX");
m=matrix();
colnames(m)<-c("colA");
i at .Data=m;
# >i
# An object of class ?XXX?
# colA
#[1,] NA
#________________________________________________________________________
#First Test
"varnames<-" <- function(x,value){
2004 Jun 29
2
T100P-E100P circuit board differences
Hi-
Perhaps someone with an E100P in hand can answer this:
I just received an E100P from Digium (I normally buy quad boards)
I noticed that the circuit board says "T100P" on it, and I assume that the
T100P and E100P both use the same circuit board.
Can someone please confirm that their E100P says "T100P" on the artwork?
Thanks
Scott
Scott M. Stingel
Emerging Voice
2005 Feb 28
1
Question about vidmode switching (WoW related)
Hello. Hopefully I didn't miss this in the archives, so here goes.
I've been running World of Warcraft in the CVS version of wine. The game
runs perfectly as far as I'm concerned. However, if I run the game at a
resolution lower than the desktop resolution it's not quite right. It
switches to a view port of the specified size rather than resizing the
whole desktop. this means I
2003 Aug 12
1
Conference + E100P + H323
Hello,
I have a E100P card from digium and I try to implement a conference bridge in asterisk.
I wonder since I got the E100P card do I still need to load ztdummy for caller from h323 endpoints to work with Meetme?
I load the E100P driver but i did not load the ztdummy driver. My h323 caller does not hear any voice play by Meetme.
Looks like ztdummy is required as long as h323 is concern and
2004 May 16
4
X100P Ireland Red Alarm (AR Tarzi)
Ahhh this could be my problem! I just checked which
wires on the RJ11 cable had a voltage across them and
it was the yellow and green (3 & 4?). From what
someone posted the other day it's supposed to be
Bumble Bee and Christmas Tree.
I did have to get a technician out to fix my line when
it was first installed because it was dead. Maybe he
wired it up incorrectly or maybe they just do it