2004 Dec 03
3
Two zaptel T1 cards: no clock from one
List,
I have a TE410P (T1 mode, all PRI) and a T100P (fxoks, for fxs channel
bank). I cannot seem to get the T100P to send any clock to the
channel bank. I prefer that it use the same clock source as the
TE410P, but it doesn't matter if it's not in sync just as long as it's
there.
The TE410P is configured 3x pri_cpe, 1x pri_net. The three cpe go to
XO Sonus switch, the net to
2004 Jun 14
1
TE410P in Austria
hi all,
i've now installed a TE410P (Quad T1/E1 Primary Card - Digium) and
connected it to a primary line. My telco (eTel) only told me that they
are using hdb3 and crc4. So i still don't know which coding i have to
use (cas or ccs) - and what timing options i have to use.
Have someone already get a card like this up in Austria with a line from
eTel or from the telekom Austria ?
Another
2004 Apr 07
2
Siemens EWSD 13
Hi all,
Has anyone got any experience with hooking Asterisk up with a
Siemens EWSD 13 switch over a E1/PRI ?
We're located in Belgium (Europe) and one of our telecom partners
uses this switch.
We connected one of our TE410P ports with their switch, but the status
light on the TE410P card keeps blinking red.
On their side they are getting a DSA (distance service alarm) error, so
this
2004 Jul 02
1
TE410P PINS
hi all,
i am getting crazy with my TE410P - it won't work
now we already think that the only thing which can be wrong is the
cable.
At our telecom endpoint we have 1-2 tx, 4-5 rx
So - which cable do i need to get it working
Already tried a cross over cable 1-2 -> 4-5 / 4-5 -> 1-2 (with this
cable nothing works -> red alarm on both ends)
Also a normal cable 1-2 -> 1-2 / 4-5 ->
2006 Apr 22
4
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
Can't anyone stop self-promotion and tell the poor guy what he needs.
A T1/E1 X-over cable using an RJ-45 (8-cond.) is pinned out as follows:
1 - 4
2 - 5
3 - NU
4 - 1
5 - 2
6 - NU
7 - NU
8 - NU
NU = Not Used
I have not in my experience seen any problems with using a Good Quality
Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you
should be fine. As far as the shielding
2004 Apr 30
1
Configuring Digium TE405P for use in Germany
Hello all,
I really checked voip-info.org but it still seems to be not very easy and I
just hope that there is anybody with a simular config.
We have one PRI (euroisdn with 30 channels) coming from the DTAG. The second
PRI should be connected to a Siemens Hicom 150E Pro Office PBX (was cheaper
than a channel bank :-)
Carrier ----S2M------ * -----S2M------Siemens
|
|
2010 Jun 22
4
Anybody using TE410P on BT ISDN with DAHDI?
Is anybody else using the following combination:
* a TE410P card (wct4xxp driver)
* a BT ISDN connection
* DAHDI 2.3.0.1
* Asterisk 1.6.2.9
I'm trying to configure a new box to replace a legacy system (same hardware;
some old version of Asterisk with Zaptel; works lovely but hopelessly
out-of-date) and not having much joy. Specifically, I couldn't get it to
see a D-channel on
2005 Jan 04
1
HDLC Bad FCS (8) HDLC Abort on TE410P
Dear All,
we have installed a TE410P card on a Dell Poweredge 1750 running a slackware
10 with 2.4.26 Kernel. Then we have made two loops on the card and we have
configurated all the 120 channels. Our goals was to perform some stess tests
even if in this scenario we used the same box as generator and target.
The stress test comprised to generate up to 60 calls at the same time by
placing a file
2005 Jan 06
1
TE410P problem (Looping UP Span 1...)
Hi list,
We have been trying to configure a Quad Span T1 card in a system running RH9. We have followed the instructions in the Wiki and searched the mailing lists, but so far havent got any success. Cable is connected to the first span, and module is loaded. Without loading the module the LED glows in red colour, but the moment we load module, it goes off. (No red or green) .
We ran zttool
2004 Jun 28
1
TE410P -> Dialogic D240SC
Basically, have an old IVR application running under Apex's Omnivox software on a box with 4 old intel dialogic D240SCs, and would like to allow remote clients to gain access to aforementioned IVR application via softphone, 7960, ata, etc via asterisk with a TE410P.
Unfortunately, all I know about the dialogics is that they're configured for D4/AMI, which I believe I have configured right
2007 Aug 24
2
TE210P digim card PRI problem
Dear all
I have now install TE210P 2 port E1 card on asterisk 1.4.10 on centOS 5 but thing is that i have connect 1 E1 port with avaya E1 back 2 back and second E1 card on Direct Telcom for outgoing for outside now i got this error when i call on avaya PRI
asterisk think PRI_CPE and remote end also CPE
i have configure /etc/zaptel.conf
span=1,1,0,ccs,hdb3
2004 Sep 07
2
TE410P in Germany
Is there anyone successfully using the TE410P with a German "PMX-Anschluss"?
Please just drop me a note mentioning the carrier you use.
We are having problems making the card work, although configuration is
correct (Posted this before). Our carrier blames the card for this. We would
just need some evidence that it really works.
Thanks,
Henrik
-------------- next part
2005 Jun 06
5
IRQ Problems
Hello
I just installed a TE110P in a Dell Poweredge 750 (rackmount), which
is connected via crossover T1 cable to a adit 600. Anyway, I've
encountered an array of errors, which I believe I have narrowed down
to the 22 IRQ misses I encounter on zttool. I've noticed that the
te110p and the usb device share an IRQ. Could that be the source of my
woes? Would disabling the usb device in the
2003 Sep 25
3
configuring TE410P for four E1 PRI lines
hi,
I'm trying to configure my newly acquired TE410P card to work as 4
E1 spans. This is
supposed to be a drop-in replacement to the earlier E100P card. However,
on loading the
zaptel module it gets configured as T1 spans basically doing a 'cat' on
/proc/zaptel/1 thru 4,
it shows 24 channels per span. After this ztcfg fails saying
'ZT_CHANCONFIG failed for channel 97'.
2005 Jun 15
2
Nasty little incident ...
We have a te410p, with the following connections:
span 1 connected to a 32 Channel EuroISDN
span 2 connected to a card in a legacy pbx (Meridian)
span 3 connected to a 10 Channel EuroISDN
span 4 connected to a card in a legacy pbx (Meridian)
We have no need for the meridian now, and decided to turn it off. I did
not change the zaptel.conf settings, nor the zapata.conf settings.
When the
2003 Sep 26
3
FCC/Euro/Aussie approvals on TE410P
I just got back from Boston where we completed testing of the TE410P for
FCC, Euro, and Australian approvals, and I'm happy to say we passed all
our approvals (including Q.921 and Q.931 layers, i.e. libpri as well as
surges) for both telco and leased line applications. Hopefully we'll have
the official documents soon, but I know there are a lot of you out there
that are happy to hear
2004 Aug 12
5
Question about TE405P
Hi all,
Does somebody know how I have to setup my TE405P ?
Is it correct my configuration below ? Otherwise, can somebody help me ?
Thanks,
Angel.
zaptel.conf
span=1,1,0,ccs,hdb3
span=2,0,1,ccs,hdb3
span=3,0,1,ccs,hdb3
span=4,0,1,ccs,hdb3
bchan=1-15
dchan=16
bchan=17-31
bchan=1-15
dchan=16
bchan=17-31
bchan=1-15
dchan=16
bchan=17-31
2006 Aug 28
3
lost packets when bridging zap and iax
We have a machine with a TE410P in it acting as a client to route calls
via iax2 to our central server,
caller --> ( zap -> iax ) ---> ( iax -> whatever ) --> called
client server
often the called can't hear the caller (both machines on public ip)
'iax2 show netstats" on client machine shows more and more dropped
packets on the
2004 Dec 14
2
Verizon PRI Setup Problems - Only Busy and Congestion
Hi -
We're moving up in the world to a PRI (Verizon), and I'm having some
problems with it. I'm new to this PRI thing, though, so maybe I've
just screwed up a simple config detail. I've got a TE410P on a Dell
PE1600SC (ServerWorks Chipset). The card itself has a green light for
the PRI, and Zttool shows Span1 as "OK". All I'm getting when I call
into any
2004 Jul 02
3
IRQ Misses and Dropped Calls?
Hello everyone,
I'm using a TE410P, no irq sharing, and all extraneous devices disabled,
such as USB, Parallel etc. I'm getting a few IRQ misses according to
ZTTOOL.
We're running a standard PRI_CPE interface and seem to be getting
dropped calls, and errors on the D-CHANNEL occasionally. The circuit
itself is very solid, it was in use on our old PBX just a few weeks ago,
never