Displaying 20 results from an estimated 11000 matches similar to: "line battery check"
2006 Jan 28
1
Should I use gbde or geli?
Hello out there, everybody!
I was actually expecting to find several (hundred) threads with this
subject being discussed. To my surprise I didn't find a single one
either on these mailing lists or in the newsgroups - at least not in a
language I understand. :-)
I realize that gbde and geli are not designed to be better than the
other but that both fit different needs and different tastes.
2003 May 06
9
SIP configuration question
First question: Do you need to use a special phone to use SIP? My setup is
X100P and TDM10B (I have 2 computers with the same setup), will I be able to
use SIP?
I already have the two computers calling each other using IAX, but I would
like to see if I can get them to work using SIP.
My current setup:
On computer 192.168.10.50
**sip.conf***
[general]
port=5060
bindaddr=0.0.0.0
2006 Feb 02
1
Zhone channel Banks
I've got a Zhone 24 port FXS to configure. The configuration is
beyond stupid. The people that designed this unit should be chased
down and fired.
I'm going around in circles frigging with all the options. Does
anyone have a config file for this unit that I can use as a starting
point?
-bill
wlloyd@slap.net
2006 Feb 15
2
Alarmreceiver
Hi,
I just want to ask if anyone has some experience with Alarmreceiver application in * 1.2? Is this application reliable (according to wiki it isn't)?
I managed to communicate Asterisk (Alarmreceiver) with a burglar alarm, but it behaves very strange. Sometimes alarmreceiver is able to get some events but sometimes not.
Maybe there are some other non commercial applications which work under
2009 Jan 19
4
Description of Zaptel/DAHDI E1 alarms
Hello,
I am missing any description of zaptel/DAHDI alarms. The TE200 series
user manual contains only a description of LEDs states. These alarms
states are visible in zttool/dahditool or in astersick CLI (zap show
status) and I wonder what is the real meaning of these alarms for E1
channel.
Possible alarm states (based on zaptel.h 1.2):
1. No alarms
2. Recovering from alarm
3. In loopback
2004 Mar 16
7
PRI Errors
I just had the same exact problem this morning. The only thing I've done in the last couple of days is update update zaptel. I rolled back my zaptel to 2/11/04 from 3/8/04. And kept my libpri from 3/8/04. I never had this error before updated. I had other issues, but not this one.
-sb
-----Original Message-----
From: asterisk-users-admin@lists.digium.com
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
4
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
Hi
debian jessie, nut 2.7.2-4
APC Smart-UPS 1500 connected through USB, running nut driver usbhid-ups
This UPS powers my switches, internet connection and my monitor server that
monitors this and my other UPSes + runs smokeping and nagios.
But recently a powerloss seemed to have shutdown my monitor PC immediately, so
it did not shut down the other servers cleanly. Power seem to be lost
2007 May 11
4
Dry Copper Pair
Hi,
Does anyone know of a way to get a dry copper pair (also known as an alarm
line) from Verizon for less than $20/end? I know we have been able to get
them, but they come out to $40/month for a circuit.. and there's no
dial-tone over it!!!!
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2005 Aug 11
14
How to fix a Blue Alarm?? Line Noise?
We are having line noise issues in our Asterisk to legacy PBX integration.
All SIP calls originating from IP phones sound crystal clear. All calls that
originate from the legacy PBX (Isoetec 228) and route through the Asterisk
and out SIP have a lot of line noise.
I believe I have it pinned down to these Blue Alarm errors that I can see on
the legacy PBX side. zttool shows no alarm but when I
2006 Dec 03
11
Is there any Asterisk controllable thermostat?
I am wondering if there is any such thermostat available which can be
controlled from Asterisk. Like you call your home pbx, dial some extension,
e.g. 333 and it asks to set the temperature, you enter a temperature, and it
sets the thermostat to that temperature. This thermostat will be very
useful, e.g. when you're coming back home after a few days and now its
snowing and you want home to be
2003 Dec 30
2
E100P configuration
Hi !
I am trying to configure two E100P cards, but I am a bit confused with
zapta.conf in what I am trying to achieve.
The * will be connected to a pstn switch with two E1 PRI lines. The E1 lines
will be used for incoming calls as well as outgoing calls.
My problem now is what to put in zapta.conf, I would like to group all
channels from both cards together (if that's possible). Does this
2015 Jun 16
3
FXS Solutions for modems and other non jitter tolerant devices
In the past we have used Adtran Atlas 550's to break out FXS ports for
devices like modems. The great thing about the 550 is that internally it
is all TDM so there is absolutely zero latency.
We are able to use ATA's for faxes and analog phones but devices that use
modems, they fail 99.99% of the time when using an ATA.
We tried to migrate to TA908 devices; they have FXS ports built
2004 Jul 02
1
TE410P PINS
hi all,
i am getting crazy with my TE410P - it won't work
now we already think that the only thing which can be wrong is the
cable.
At our telecom endpoint we have 1-2 tx, 4-5 rx
So - which cable do i need to get it working
Already tried a cross over cable 1-2 -> 4-5 / 4-5 -> 1-2 (with this
cable nothing works -> red alarm on both ends)
Also a normal cable 1-2 -> 1-2 / 4-5 ->
2004 Jan 10
2
drop calls with T100P / PRI
Hi List,
a number of our customers are reporting dropped calls.
here is the config.
1 T100P T1 Card
1 Asterisk (Mid Nov build)
T1 is signalled as a PRI(National)
The card will only sync up if we clock, if
we line side clock the card goes into yellow alarm
and won't sync up.
the only errors we see are framing slips.
Around 2500 slips over a 18 hour period.
(this was reported from
2004 Apr 12
5
T100P / ZAP / PRI errors
My PRI is being reset at least once a day with the following errors in the
logs.
zaptel, zapata, libpri, and asterisk are from CVS this morning.. This has
been happening for weeks on all versions (including -stable).
the T100P card appears to NOT be sharing an IRQ.
xenon# cat /proc/interupts
CPU0
0: 1203977 XT-PIC timer
1: 3 XT-PIC keyboard
2:
2003 Dec 03
2
COnfiguring an * system for a non-profit organization
Hi,
Maybe someone has seen this before...
I've installed a new T100P, but it doesn't seem to work. I've attached
the T100P to an Adtran 750 using a crossover cable. The Adtran shows a
red alarm on the T1 interface. The Adtran has been set to factory
defaults with FXS cards in 1-3 and an FXO card in 5.
The T100P shows no signs of life--the leds are not lit. Should I be
seeing
2003 Nov 07
1
Asterisk can't connect voice
HI Asterisk Gurus
I'm connecting my * server to a zplex 10B, I'm using a slot on my TE410P
card as T1 to connect my server to the channel bank (i use a cross cable),
the zplex doesn't show any alarm neither the server. I'm trying to make
calls from (ext 1) from the channel bank, to other (ext 2) in the same
channel bank, but when I dial the ext number, the dialtone doesn't
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On 04/03/2017 07:03 PM, Gene Heskett wrote:
>
> But it does that because you have tried to get 12 years out of a gell
> cell battery that is doing really really well if you get 4 years out of
> it. I am not saying you should do that _now_, without first replacing
> that thoroughly boiled dry battery, but as something you should set it
> up to do once you have a serviceable
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 04
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On Tue, 4 Apr 2017, Arnaud Quette wrote:
> Hi Jon, Stuart and the list
>
> 2017-04-04 1:09 GMT+02:00 Stuart Gathman <stuart at gathman.org>:
> Which NOTIFYCMD is run when there is an ALARM?
> Have you specified that in your upsmon.conf?
>
> And that is the question of the hour.? How do you specify that?? Note
> that this is not the REPLBATT