Displaying 15 results from an estimated 15 matches for "unpow".
Did you mean:
unp_w
2006 Mar 05
6
Polycom 501 power over ethernet
...me.
Polycom must have some odd voltage or funny way of injecting the
power, because the POE switch I bought for them (Netgear F@510P)
won't power them, though if I use the Polycom-supplied AC adapter and
ethernet power injector cable, they work with the switch in either
its powered or unpowered ports.
Anyhow, I hadn't seen any mention of how people power these phones,
as I had planned on centralizing phone power on a UPS to supply my
Asterisk server and POE switch. Now the question is:
Can the Polycom AC-powered injector be used with a standard ethernet
patch cable:
swi...
2014 Jan 23
2
Shutdown when both (all) UPS on battery / low battery
...:24 AM, Rafal Oleszek wrote:
> I tried all options:
> 1,2
> and in MINSUPPLIES: 1,2,3,4
> still didn't work.
My mistake - I gave you the wrong advice before. For MINSUPPLIES, I'm used to either a 1:1 UPS-to-server ratio, or 2:1 where the server can run with either power supply unpowered.
I just tried this in upsmon.conf:
MONITOR dummy1 1 monuser password slave
MONITOR dummy2 1 monuser password slave
MINSUPPLIES 1
With only one dummy-ups set to "OB LB", upsmon kept polling. When both were set to "OB LB", it tried to shut down the system.
That was with NU...
2007 Apr 12
1
APC 1500 USB problem
...usbdevs output:
addr 2: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion
addr 3: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion
(UPS1 and UPS2)
I've configured our NUT system to monitor the UPSes, and it went very
fine till the time had arrived for a test. UPS unpower (-> ONBAT), and
test what NUT does to the boxes connected to it.
After I've unplugged the power cable of UPS1, nut started not to notice
that on its cgi interface. It was showing a duplicate of the on-power
UPS.
After this I've restarted the NUT ups daemon and thus the drivers along...
2014 Jan 21
2
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 8:05 AM, Rafa? Oleszek wrote:
> MONITOR UPS_251 at localhost 2 monmaster password master
> MONITOR UPS_252 at localhost 2 monmaster password master
I think the "2"s here should be "1".
"powervalue is an integer representing the number of power supplies that the UPS feeds *on this system*."
So if UPS_251 is connected to one power supply on
2014 Jan 21
0
Shutdown when both (all) UPS on battery / low battery
I tried all options:
1,2
and in MINSUPPLIES: 1,2,3,4
still didn't work.
UPS_251 and UPS_252 feeds all environment and it's not feed directly one
server, but many of them.
> On Jan 21, 2014, at 8:05 AM, Rafa? Oleszek wrote:
>
>> MONITOR UPS_251 at localhost 2 monmaster password master
>> MONITOR UPS_252 at localhost 2 monmaster password master
>
> I think the
2004 Apr 06
0
HELP! - weird 7960 problem - phone goes nuts - display flashes - phone reboots
I have a strange problem rolling through my 7960 phones.
One or more of the phones goes crazy when the first digit is dialed. The
display flashes repeatedly, the phone does a bunch of stuff, sometimes it
even reboots.
It's not the powered switch, the same thing happens with a different
unpowered switch.
It's not the phone, the problem moves from phone to phone. If it's happening
to a phone and I restart everything, when everything is back up a different
phone will have the problem.
has anyone seen this?
Thanks!
Paul
Paul Mahler
pmahler@signate.com
------------...
2004 Sep 27
11
sipura over heat
I'm experiencing a very unusual problem with a few of my sipuras. They keep
over heating after minimal usage. I unplug them and let them sit for 15
minutes and it starts working fine. The other way around is that I put a
fan on it or something to keep it cooling.
Has anyone else experienced this or are they just defective units?
Regards,
Mohammed Salim
EZZI Telecom, Inc.
2006 Jun 04
1
Problem with dual-booting soft-RAID
...ay have given it the wrong parameter), so I used grub directly:
root (hd1,0)
setup (hd1)
That's correct, isn't it? (Is there a way to determine if grub is
installed on the correct disk?)
I added a third boot entry to the grub.conf (see below).
I then removed disk 1 (hda) from the array by unpowering it and rebooted.
Unfortunately, that sent me right in the BIOS PXE boot instead of trying
the other disk, well, that's a BIOS problem. So I repowered disk 1 and
rebooted. The grub on it is still working somehow but just fills the
screen with "grub". So I moved disk 2 before d...
2014 Jan 23
0
Shutdown when both (all) UPS on battery / low battery
...gt; I tried all options:
>> 1,2
>> and in MINSUPPLIES: 1,2,3,4
>> still didn't work.
>
> My mistake - I gave you the wrong advice before. For MINSUPPLIES, I'm used
> to either a 1:1 UPS-to-server ratio, or 2:1 where the server can run with
> either power supply unpowered.
>
> I just tried this in upsmon.conf:
>
> MONITOR dummy1 1 monuser password slave
> MONITOR dummy2 1 monuser password slave
> MINSUPPLIES 1
>
> With only one dummy-ups set to "OB LB", upsmon kept polling. When both
> were set to "OB LB", it tried...
2004 Mar 22
3
First impressions of iRiver iHP120
Battery life sucks.
This may be due to three factors:
1. It was the first charge that the machine had
2. Playing Vorbis takes more battery power than MP3
3. The battery is a bit rubbish
More considered opinions to follow.
Phil Hibbs
Cap Gemini Ernst & Young
Aston, UK
<p>=======================================================
This message contains information that may be privileged
2015 Jan 23
2
a dedicated audio encoder
...ed - FIQ reported NYET. Data may have been lost.
And recordings were choppy, clicking etc.
This is all running the Pi at normal setup with USB2 enabled and Xenyx USB
directly connected to the Pi with a 1.5m usb A-B cable.
Then, I connected a usb hub to the Pi and then the Xenyx USB to the hub.
Unpowered el cheapo hub. Tried another al cheapo crappy usb2 hub that
never worked when connecting it between a UMTS dongle and a PC (dongle
just would get up and running, probably power issues). Both did the magic
trick: recording now works like a charm.
Once did I see an "overrun!!! (at least...
2015 Jan 22
2
a dedicated audio encoder
Hi u,
On Thu, 22 Jan 2015, unosonic wrote:
> well, sort of, with a PI, Ices2 as a client, and an USB audio device as
> input, e.g. a "class compliant" audio recoder like Olympus LS5, Zoom H2
> etc., but also a little mixer like the Behringer Xenyx 302 USB.
> The problem i've encountered is with USB class1 devices, i.e. so called
> "full speed" USB (which is
2007 Oct 21
8
[Bug 12875] New: swfdec-mozilla-0.5.3: cpu hog and reports incorrect youtube video length
http://bugs.freedesktop.org/show_bug.cgi?id=12875
Summary: swfdec-mozilla-0.5.3: cpu hog and reports incorrect
youtube video length
Product: swfdec
Version: 0.5.3
Platform: x86-64 (AMD64)
OS/Version: Linux (All)
Status: NEW
Severity: normal
Priority: medium
Component: plugin
2006 Apr 21
10
Power over Ethernet (PoE) switch recommendations
Hi listers,
I am looking for people who have used Power over Ethernet switches, primarily in conjunction with Polycom IP 501's. I've been looking at the Linksys SRW224P, since I've had good luck with the SRW224 in our office. However, Nortel, Cisco, Adtran, etc. all have an offering, all of which vary in price. I would appreciate any input people have to offer.
Thanks,
James
2005 May 31
10
UPS rating for SOHO asterisk box
Slightly OT, but I think this is of possible interest to many of you,
I need to get a UPS for my asterisk box. They are rated in VA but I
can't quite figure out how that converts to real life.
I have a PIII-800 box with two X100P and one TDM400P plus graphics
adapter, an IDE hard drive etc. Will a small 400VA box be enough for
this?
tia