search for: realpow

Displaying 20 results from an estimated 176 matches for "realpow".

Did you mean: realpop
2016 May 20
1
ups.status don't switch to "OB LB"
...driver.parameter.pollfreq: 5 driver.parameter.pollinterval: 2 driver.parameter.port: 192.168.99.60 driver.parameter.snmp_version: v2c driver.version: 2.7.2 driver.version.data: ietf MIB 1.4 driver.version.internal: 0.72 input.bypass.L1-N.voltage: 236.00 input.bypass.L1.current: 0.00 input.bypass.L1.realpower: 0.00 input.bypass.L2-N.voltage: 237.00 input.bypass.L2.current: 0.00 input.bypass.L2.realpower: 0.00 input.bypass.L3-N.voltage: 236.00 input.bypass.L3.current: 0.00 input.bypass.L3.realpower: 0.00 input.bypass.phases: 3.00 input.frequency.nominal: 0.00 input.L1-N.voltage: 236.00 input.L1.current...
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
...: 132 input.voltage: 116.7 input.voltage.extended: no input.voltage.nominal: 120 outlet.1.autoswitch.charge.low: 0 outlet.1.current: 3.70 outlet.1.delay.shutdown: 65535 outlet.1.delay.start: 3 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 1 outlet.1.power: 432 outlet.1.powerfactor: 94.00 outlet.1.realpower: 410 outlet.1.status: on outlet.1.switchable: yes outlet.2.autoswitch.charge.low: 0 outlet.2.current: 5.50 outlet.2.delay.shutdown: 65535 outlet.2.delay.start: 6 outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 2 outlet.2.power: 630 outlet.2.powerfactor: 97.00 outlet.2.realpower: 616 outlet.2.stat...
2010 Dec 14
1
Setting Battery Runtime Low
...erval: 2 driver.parameter.port: 192.168.10.25 driver.version: 2.4.3 driver.version.internal: 0.47 (mib: pw 0.6.1) input.bypass.L1-N.voltage: 249.00 input.bypass.L2-N.voltage: 250.00 input.bypass.L3-N.voltage: 251.00 input.frequency: 50.10 input.L1-N.voltage: 249.00 input.L1.current: 183.00 input.L1.realpower: 42182.00 input.L2-N.voltage: 250.00 input.L2.current: 184.00 input.L2.realpower: 42366.00 input.L3-N.voltage: 250.00 input.L3.current: 184.00 input.L3.realpower: 42251.00 input.phases: 3.00 input.quality: 0.00 input.voltage.nominal: 239.00 output.frequency: 50.10 output.frequency.nominal: 50.00...
2007 Dec 11
2
nut-2.2.1-pre2
Shamelessly reusing the announcement Arnaud sent about three months ago for nut-2.2.1: "We're preparing to release 2.2.1-pre2, so if you have some fixes to backport on Testing, consider announcing it and doing asap. As always, compatibilities update and bugfixes only!" Regards, Arjen -- Eindhoven - The Netherlands Key fingerprint - 66 4E 03 2C 9D B5 CB 9B 7A FE 7E C1
2014 Mar 31
0
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card [UPDATE]
...ver.parameter.pollfreq: 15 driver.parameter.pollinterval: 2 driver.parameter.port: 10.2.1.226 driver.parameter.snmp_version: v1 driver.version: 2.7.1 driver.version.data: cpqpower MIB 1.5 driver.version.internal: 0.70 input.frequency: 50.00 input.L1-N.voltage: 224.00 input.L1.current: 0.70 input.L1.realpower: 0.00 input.L2-N.voltage: 223.00 input.L2.current: 1.00 input.L2.realpower: 0.00 input.L3-N.voltage: 223.00 input.L3.current: 0.60 input.L3.realpower: 0.00 input.phases: 3.00 input.quality: 0.00 outlet.count: 0.00 outlet.desc: All outlets outlet.id: 0 output.frequency: 50.00 output.L1-N.voltage:...
2010 Apr 21
2
liebert-esp2 patch (3-phase support)
...l: 50.0 output.frequency: 50.0 output.L1-N.voltage: 230.8 output.L1.crestfactor: 2.1 output.L2-N.voltage: 230.4 output.L2.crestfactor: 2.7 output.L3-N.voltage: 230.4 output.L3.crestfactor: 2.0 output.phases: 3 ups.delay.start: 900 ups.firmware: I170R150M260 ups.L1.load: 21 ups.L1.power: 1400 ups.L1.realpower: 1000 ups.L2.load: 20 ups.L2.power: 1400 ups.L2.realpower: 1000 ups.L3.load: 19 ups.L3.power: 1100 ups.L3.realpower: 1000 ups.mfr: Liebert ups.model: Liebert NX ups.power.nominal: 20000 ups.status: OL ups.temperature: 25.0 ups.type: online -------------- next part -------------- battery.current:...
2009 Aug 31
3
SNMP on HP UPS
..."1.3.6.1.2.1.33.1.2.6.0") not supported. battery.temperature ("1.3.6.1.2.1.33.1.2.7.0") not supported. output voltage is "1.3.6.1.2.1.33.1.4.4.1.2.1" output current is "1.3.6.1.2.1.33.1.4.4.1.3.1" The following output levels are not supported: output.realpower output.L1-N.voltage output.L2-N.voltage output.L3-N.voltage output.L1.current output.L2.current output.L3.current output.L1.realpower output.L2.realpower output.L3.realpower output.L1.power.percent output.L2.power.percent output.L3.power.percent in...
2007 Aug 11
1
apc-hid.c: watts_to_av_conversion
...e name of it made me wonder what the heck was going on. As far as I know, there is no way to convert between AV and W without knowing the phase relation between RMS voltage and -current. Could it be that for this particular UPS this works out to be correct by coincidence? Now that we have "ups.realpower.nominal", I think we should change line 215 { "ups.power.nominal", 0, 0, "UPS.Output.ConfigActivePower", NULL, "%s", HU_FLAG_OK, watts_to_av_conversion }, /* CyberPower */ to { "ups.realpower.nominal", 0, 0, "UPS.Output.ConfigActivePower&quot...
2011 Mar 31
2
Cyberpower CP850PFCLCD 120% battery charge
...driver.version.internal: 0.34 input.transfer.high: 139 input.transfer.low: 88 input.voltage: 117.0 input.voltage.nominal: 120 output.voltage: 117.0 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 56 ups.mfr: CP850PFCLCD ups.model: CRDA103.981 ups.productid: 0501 ups.realpower.nominal: 510 ups.serial: CPS ups.status: OL ups.test.result: No test initiated ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 Tue Mar 29 23:30:44 CDT 2011 battery.charge: 105 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 367 battery.run...
2017 Nov 16
1
[HCL] Riello IPG 600 supported by riello_usb / incorrect battery.charge and ups.temperature values
...ort: auto driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.internal: 0.03 input.bypass.frequency: 409.50 input.bypass.voltage: 4095 input.frequency: 50.10 input.voltage: 235 output.frequency: 50.10 output.frequency.nominal: 50.0 output.L1.current: 0 output.L1.power: 0 output.L1.realpower: 0 output.L2.current: 0 output.L2.power: 0 output.L2.realpower: 0 output.L3.current: 0 output.L3.power: 0 output.L3.realpower: 0 output.power.percent: 0 output.voltage: 233 output.voltage.nominal: 230 ups.firmware: SWM036-01-02 ups.load: 0 ups.mfr: RPS S.p.a. ups.model: USV5 ups.power.nominal: 60...
2011 Mar 16
1
Liebert PSIXR 3000 intellislot web card support with NUT 2.6.0
...snmp-ups driver.parameter.mibs: auto driver.parameter.pollinterval: 2 driver.parameter.port: 192.168.0.11 driver.version: 2.6.0 driver.version.internal: 0.50 (mib: ietf 1.3) input.bypass.phases: 0.00 input.current: 0.00 input.frequency: 50.00 input.frequency.nominal: 50.00 input.phases: 1.00 input.realpower: 0.00 input.transfer.high: 0.00 input.transfer.low: 0.00 input.voltage: 247.00 input.voltage.nominal: 2300.00 output.current: 0.00 output.frequency: 50.00 output.frequency.nominal: 50.00 output.phases: 1.00 output.power.nominal: 0.00 output.realpower: 0.00 output.realpower.nominal: 0.00 output.vo...
2014 Mar 11
2
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card [UPDATE]
...>> output.phases: 1.00 >> output.voltage: 223.00 >> output.voltage.nominal: 230 >> ups.delay.shutdown: 20 >> ups.delay.start: 30 >> ups.firmware: 01.06.0026;01.02.0004 >> ups.load: 19.00 >> ups.mfr: HP >> ups.model: HP RT3000 G2 UPS >> ups.realpower: 3000.00 >> ups.serial: 3C83435450 >> ups.status: OL OB <================ !!! >> ups.test.result: Unknown >> ups.timer.shutdown: 0.00 >> ups.timer.start: 0.00 >> ups.type: normal >> -----------------------------<cut>------------------...
2020 Sep 30
2
reset "replace battery" flag
...igh: 265 input.voltage: 227.8 input.voltage.extended: no input.voltage.nominal: 230 outlet.1.autoswitch.charge.low: 0 outlet.1.current: 0.00 outlet.1.delay.shutdown: 65535 outlet.1.delay.start: 3 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 1 outlet.1.power: 0 outlet.1.powerfactor: 0.00 outlet.1.realpower: 0 outlet.1.status: on outlet.1.switchable: yes outlet.2.autoswitch.charge.low: 0 outlet.2.current: 0.00 outlet.2.delay.shutdown: 65535 outlet.2.delay.start: 6 outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 2 outlet.2.power: 0 outlet.2.powerfactor: 0.00 outlet.2.realpower: 0 outlet.2.status: on...
2020 Sep 25
2
reset "replace battery" flag
On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote: > On 9/21/20 9:47 PM, Lionel Élie Mamane wrote: >> We have a HP R/T 3000 G4 UPS; according to the data returned by the >> usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX >> UPS LI R 3000. >> We have a stubborn "Replace Battery" alarm that stays (...): >> The
2009 Feb 04
2
[nut-commits] svn commit r1765 - in trunk: . drivers man
...gt; ups.ShortStatus) ; Don't 'invent' new variables without discussing this on the development mailinglist. Since these are probably useful only for debugging purposes, they shouldn't be exposed to the server/clients anyway. > 629 dstate_setinfo("ups.realpower", "%d", > (int)((float)(p[4]*256 + p[5]) * 0.6)) ; This suggests a fixed relationship between apparent and active power. This might be the case for the nominal values, but this is not true in the general case. So don't export 'ups.realpower' unless it is truly...
2014 Feb 27
2
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card
...s outlet.id: 0 output.current: 0.20 output.frequency: 50.00 output.frequency.nominal: 500 output.phases: 1.00 output.voltage: 223.00 output.voltage.nominal: 230 ups.delay.shutdown: 20 ups.delay.start: 30 ups.firmware: 01.06.0026;01.02.0004 ups.load: 19.00 ups.mfr: HP ups.model: HP RT3000 G2 UPS ups.realpower: 3000.00 ups.serial: 3C83435450 ups.status: OL OB <================ !!! ups.test.result: Unknown ups.timer.shutdown: 0.00 ups.timer.start: 0.00 ups.type: normal -----------------------------<cut>-------------------------------- If I use a MIB browser to inspect the .1.3.6.1....
2015 Apr 15
2
Cannot connect to a GPSER on serial, USB returning wrong data
...hases: 3 input.frequency: 5243.20 input.L1-N.voltage: 52432 input.L2-N.voltage: 52432 input.L3-N.voltage: 52432 input.phases: 3 output.frequency: 0.00 output.frequency.nominal: 5243.2 output.L1-N.voltage: 52432 output.L1.current: 52432 output.L1.power: 52432 output.L1.power.percent: 64720 output.L1.realpower: 52432 output.L2-N.voltage: 52432 output.L2.current: 52432 output.L2.power: 52432 output.L2.power.percent: 64720 output.L2.realpower: 52432 output.L3-N.voltage: 52432 output.L3.current: 52432 output.L3.power: 52432 output.L3.power.percent: 64720 output.L3.realpower: 52432 output.phases: 3 output....
2013 Sep 22
1
Question on weird output from a Compaq R3000
...put.voltage.maximum: 145.00 input.voltage.minimum: 84.00 input.voltage.nominal: 120.00 output.current: 15.15 output.current.maximum: 28.50 output.current.nominal: 25.00 output.frequency: 60.00 output.frequency.maximum: 63.00 output.frequency.minimum: 57.00 output.phases: 1 output.power: 1.82 output.realpower: 1810.00 output.realpower.nominal: 2250.00 output.voltage: 121.00 output.voltage.maximum: 128.00 output.voltage.minimum: 108.00 output.voltage.nominal: 120.00 ups.delay.reboot: 060 ups.delay.shutdown: 180 ups.load: 60.6 ups.mfr: unknown ups.model: UPS 3000 VA FW -0026 ups.power.nominal: 3000.00 u...
2008 Oct 30
2
Adding PDU support to NUT
...three phase) and possibly device.id device.firmware device.temperature * the outlet collection has to be extended with the following data: outlet.n.current: Current (milliamps RMS) outlet.n.current.maximum: Maximum seen current (milliamps RMS) outlet.n.realpower: Current value of real power (Watts) outlet.n.voltage: Voltage (V) outlet.n.powerfactor: Power Factor (dimensionless value between 0.00 and 1.00) outlet.n.power: Apparent power (VA) - status_{}() needs only to process when device.type=ups More generally, I think that NUT i...
2012 Aug 30
2
UPS - CYBERPOWER CPS DX600E supported by usbhid-ups
...berPower HID 0.3 driver.version.internal: 0.35 input.transfer.high: 0 input.transfer.low: 0 input.voltage: 230.0 input.voltage.nominal: 230 output.voltage: 239.0 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 21 ups.mfr: CPS ups.model: DX600E ups.productid: 0501 ups.realpower.nominal: 360 ups.status: OL ups.timer.shutdown: -60 ups.timer.start: 0 ups.vendorid: 0764