Displaying 20 results from an estimated 176 matches for "realpow".
Did you mean:
realpop
2016 May 20
1
ups.status don't switch to "OB LB"
...driver.parameter.pollfreq: 5
driver.parameter.pollinterval: 2
driver.parameter.port: 192.168.99.60
driver.parameter.snmp_version: v2c
driver.version: 2.7.2
driver.version.data: ietf MIB 1.4
driver.version.internal: 0.72
input.bypass.L1-N.voltage: 236.00
input.bypass.L1.current: 0.00
input.bypass.L1.realpower: 0.00
input.bypass.L2-N.voltage: 237.00
input.bypass.L2.current: 0.00
input.bypass.L2.realpower: 0.00
input.bypass.L3-N.voltage: 236.00
input.bypass.L3.current: 0.00
input.bypass.L3.realpower: 0.00
input.bypass.phases: 3.00
input.frequency.nominal: 0.00
input.L1-N.voltage: 236.00
input.L1.current...
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
...: 132
input.voltage: 116.7
input.voltage.extended: no
input.voltage.nominal: 120
outlet.1.autoswitch.charge.low: 0
outlet.1.current: 3.70
outlet.1.delay.shutdown: 65535
outlet.1.delay.start: 3
outlet.1.desc: PowerShare Outlet 1
outlet.1.id: 1
outlet.1.power: 432
outlet.1.powerfactor: 94.00
outlet.1.realpower: 410
outlet.1.status: on
outlet.1.switchable: yes
outlet.2.autoswitch.charge.low: 0
outlet.2.current: 5.50
outlet.2.delay.shutdown: 65535
outlet.2.delay.start: 6
outlet.2.desc: PowerShare Outlet 2
outlet.2.id: 2
outlet.2.power: 630
outlet.2.powerfactor: 97.00
outlet.2.realpower: 616
outlet.2.stat...
2010 Dec 14
1
Setting Battery Runtime Low
...erval: 2
driver.parameter.port: 192.168.10.25
driver.version: 2.4.3
driver.version.internal: 0.47 (mib: pw 0.6.1)
input.bypass.L1-N.voltage: 249.00
input.bypass.L2-N.voltage: 250.00
input.bypass.L3-N.voltage: 251.00
input.frequency: 50.10
input.L1-N.voltage: 249.00
input.L1.current: 183.00
input.L1.realpower: 42182.00
input.L2-N.voltage: 250.00
input.L2.current: 184.00
input.L2.realpower: 42366.00
input.L3-N.voltage: 250.00
input.L3.current: 184.00
input.L3.realpower: 42251.00
input.phases: 3.00
input.quality: 0.00
input.voltage.nominal: 239.00
output.frequency: 50.10
output.frequency.nominal: 50.00...
2007 Dec 11
2
nut-2.2.1-pre2
Shamelessly reusing the announcement Arnaud sent about three months ago
for nut-2.2.1:
"We're preparing to release 2.2.1-pre2, so if you have some fixes to
backport on Testing, consider announcing it and doing asap.
As always, compatibilities update and bugfixes only!"
Regards, Arjen
--
Eindhoven - The Netherlands
Key fingerprint - 66 4E 03 2C 9D B5 CB 9B 7A FE 7E C1
2014 Mar 31
0
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card [UPDATE]
...ver.parameter.pollfreq: 15
driver.parameter.pollinterval: 2
driver.parameter.port: 10.2.1.226
driver.parameter.snmp_version: v1
driver.version: 2.7.1
driver.version.data: cpqpower MIB 1.5
driver.version.internal: 0.70
input.frequency: 50.00
input.L1-N.voltage: 224.00
input.L1.current: 0.70
input.L1.realpower: 0.00
input.L2-N.voltage: 223.00
input.L2.current: 1.00
input.L2.realpower: 0.00
input.L3-N.voltage: 223.00
input.L3.current: 0.60
input.L3.realpower: 0.00
input.phases: 3.00
input.quality: 0.00
outlet.count: 0.00
outlet.desc: All outlets
outlet.id: 0
output.frequency: 50.00
output.L1-N.voltage:...
2010 Apr 21
2
liebert-esp2 patch (3-phase support)
...l: 50.0
output.frequency: 50.0
output.L1-N.voltage: 230.8
output.L1.crestfactor: 2.1
output.L2-N.voltage: 230.4
output.L2.crestfactor: 2.7
output.L3-N.voltage: 230.4
output.L3.crestfactor: 2.0
output.phases: 3
ups.delay.start: 900
ups.firmware: I170R150M260
ups.L1.load: 21
ups.L1.power: 1400
ups.L1.realpower: 1000
ups.L2.load: 20
ups.L2.power: 1400
ups.L2.realpower: 1000
ups.L3.load: 19
ups.L3.power: 1100
ups.L3.realpower: 1000
ups.mfr: Liebert
ups.model: Liebert NX
ups.power.nominal: 20000
ups.status: OL
ups.temperature: 25.0
ups.type: online
-------------- next part --------------
battery.current:...
2009 Aug 31
3
SNMP on HP UPS
..."1.3.6.1.2.1.33.1.2.6.0") not supported.
battery.temperature ("1.3.6.1.2.1.33.1.2.7.0") not supported.
output voltage is "1.3.6.1.2.1.33.1.4.4.1.2.1"
output current is "1.3.6.1.2.1.33.1.4.4.1.3.1"
The following output levels are not supported:
output.realpower
output.L1-N.voltage
output.L2-N.voltage
output.L3-N.voltage
output.L1.current
output.L2.current
output.L3.current
output.L1.realpower
output.L2.realpower
output.L3.realpower
output.L1.power.percent
output.L2.power.percent
output.L3.power.percent
in...
2007 Aug 11
1
apc-hid.c: watts_to_av_conversion
...e name of it made me wonder what the
heck was going on. As far as I know, there is no way to convert between AV
and W without knowing the phase relation between RMS voltage and -current.
Could it be that for this particular UPS this works out to be correct by
coincidence? Now that we have "ups.realpower.nominal", I think we should
change line 215
{ "ups.power.nominal", 0, 0, "UPS.Output.ConfigActivePower", NULL, "%s",
HU_FLAG_OK, watts_to_av_conversion }, /* CyberPower */
to
{ "ups.realpower.nominal", 0, 0, "UPS.Output.ConfigActivePower"...
2011 Mar 31
2
Cyberpower CP850PFCLCD 120% battery charge
...driver.version.internal: 0.34
input.transfer.high: 139
input.transfer.low: 88
input.voltage: 117.0
input.voltage.nominal: 120
output.voltage: 117.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 56
ups.mfr: CP850PFCLCD
ups.model: CRDA103.981
ups.productid: 0501
ups.realpower.nominal: 510
ups.serial: CPS
ups.status: OL
ups.test.result: No test initiated
ups.timer.shutdown: -60
ups.timer.start: -60
ups.vendorid: 0764
Tue Mar 29 23:30:44 CDT 2011
battery.charge: 105
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 367
battery.run...
2017 Nov 16
1
[HCL] Riello IPG 600 supported by riello_usb / incorrect battery.charge and ups.temperature values
...ort: auto
driver.parameter.synchronous: no
driver.version: 2.7.4
driver.version.internal: 0.03
input.bypass.frequency: 409.50
input.bypass.voltage: 4095
input.frequency: 50.10
input.voltage: 235
output.frequency: 50.10
output.frequency.nominal: 50.0
output.L1.current: 0
output.L1.power: 0
output.L1.realpower: 0
output.L2.current: 0
output.L2.power: 0
output.L2.realpower: 0
output.L3.current: 0
output.L3.power: 0
output.L3.realpower: 0
output.power.percent: 0
output.voltage: 233
output.voltage.nominal: 230
ups.firmware: SWM036-01-02
ups.load: 0
ups.mfr: RPS S.p.a.
ups.model: USV5
ups.power.nominal: 60...
2011 Mar 16
1
Liebert PSIXR 3000 intellislot web card support with NUT 2.6.0
...snmp-ups
driver.parameter.mibs: auto
driver.parameter.pollinterval: 2
driver.parameter.port: 192.168.0.11
driver.version: 2.6.0
driver.version.internal: 0.50 (mib: ietf 1.3)
input.bypass.phases: 0.00
input.current: 0.00
input.frequency: 50.00
input.frequency.nominal: 50.00
input.phases: 1.00
input.realpower: 0.00
input.transfer.high: 0.00
input.transfer.low: 0.00
input.voltage: 247.00
input.voltage.nominal: 2300.00
output.current: 0.00
output.frequency: 50.00
output.frequency.nominal: 50.00
output.phases: 1.00
output.power.nominal: 0.00
output.realpower: 0.00
output.realpower.nominal: 0.00
output.vo...
2014 Mar 11
2
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card [UPDATE]
...>> output.phases: 1.00
>> output.voltage: 223.00
>> output.voltage.nominal: 230
>> ups.delay.shutdown: 20
>> ups.delay.start: 30
>> ups.firmware: 01.06.0026;01.02.0004
>> ups.load: 19.00
>> ups.mfr: HP
>> ups.model: HP RT3000 G2 UPS
>> ups.realpower: 3000.00
>> ups.serial: 3C83435450
>> ups.status: OL OB <================ !!!
>> ups.test.result: Unknown
>> ups.timer.shutdown: 0.00
>> ups.timer.start: 0.00
>> ups.type: normal
>> -----------------------------<cut>------------------...
2020 Sep 30
2
reset "replace battery" flag
...igh: 265
input.voltage: 227.8
input.voltage.extended: no
input.voltage.nominal: 230
outlet.1.autoswitch.charge.low: 0
outlet.1.current: 0.00
outlet.1.delay.shutdown: 65535
outlet.1.delay.start: 3
outlet.1.desc: PowerShare Outlet 1
outlet.1.id: 1
outlet.1.power: 0
outlet.1.powerfactor: 0.00
outlet.1.realpower: 0
outlet.1.status: on
outlet.1.switchable: yes
outlet.2.autoswitch.charge.low: 0
outlet.2.current: 0.00
outlet.2.delay.shutdown: 65535
outlet.2.delay.start: 6
outlet.2.desc: PowerShare Outlet 2
outlet.2.id: 2
outlet.2.power: 0
outlet.2.powerfactor: 0.00
outlet.2.realpower: 0
outlet.2.status: on...
2020 Sep 25
2
reset "replace battery" flag
On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote:
> On 9/21/20 9:47 PM, Lionel Élie Mamane wrote:
>> We have a HP R/T 3000 G4 UPS; according to the data returned by the
>> usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX
>> UPS LI R 3000.
>> We have a stubborn "Replace Battery" alarm that stays (...):
>> The
2009 Feb 04
2
[nut-commits] svn commit r1765 - in trunk: . drivers man
...gt; ups.ShortStatus) ;
Don't 'invent' new variables without discussing this on the
development mailinglist. Since these are probably useful only for
debugging purposes, they shouldn't be exposed to the server/clients
anyway.
> 629 dstate_setinfo("ups.realpower", "%d",
> (int)((float)(p[4]*256 + p[5]) * 0.6)) ;
This suggests a fixed relationship between apparent and active power.
This might be the case for the nominal values, but this is not true in
the general case. So don't export 'ups.realpower' unless it is truly...
2014 Feb 27
2
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card
...s
outlet.id: 0
output.current: 0.20
output.frequency: 50.00
output.frequency.nominal: 500
output.phases: 1.00
output.voltage: 223.00
output.voltage.nominal: 230
ups.delay.shutdown: 20
ups.delay.start: 30
ups.firmware: 01.06.0026;01.02.0004
ups.load: 19.00
ups.mfr: HP
ups.model: HP RT3000 G2 UPS
ups.realpower: 3000.00
ups.serial: 3C83435450
ups.status: OL OB <================ !!!
ups.test.result: Unknown
ups.timer.shutdown: 0.00
ups.timer.start: 0.00
ups.type: normal
-----------------------------<cut>--------------------------------
If I use a MIB browser to inspect the .1.3.6.1....
2015 Apr 15
2
Cannot connect to a GPSER on serial, USB returning wrong data
...hases: 3
input.frequency: 5243.20
input.L1-N.voltage: 52432
input.L2-N.voltage: 52432
input.L3-N.voltage: 52432
input.phases: 3
output.frequency: 0.00
output.frequency.nominal: 5243.2
output.L1-N.voltage: 52432
output.L1.current: 52432
output.L1.power: 52432
output.L1.power.percent: 64720
output.L1.realpower: 52432
output.L2-N.voltage: 52432
output.L2.current: 52432
output.L2.power: 52432
output.L2.power.percent: 64720
output.L2.realpower: 52432
output.L3-N.voltage: 52432
output.L3.current: 52432
output.L3.power: 52432
output.L3.power.percent: 64720
output.L3.realpower: 52432
output.phases: 3
output....
2013 Sep 22
1
Question on weird output from a Compaq R3000
...put.voltage.maximum: 145.00
input.voltage.minimum: 84.00
input.voltage.nominal: 120.00
output.current: 15.15
output.current.maximum: 28.50
output.current.nominal: 25.00
output.frequency: 60.00
output.frequency.maximum: 63.00
output.frequency.minimum: 57.00
output.phases: 1
output.power: 1.82
output.realpower: 1810.00
output.realpower.nominal: 2250.00
output.voltage: 121.00
output.voltage.maximum: 128.00
output.voltage.minimum: 108.00
output.voltage.nominal: 120.00
ups.delay.reboot: 060
ups.delay.shutdown: 180
ups.load: 60.6
ups.mfr: unknown
ups.model: UPS 3000 VA FW -0026
ups.power.nominal: 3000.00
u...
2008 Oct 30
2
Adding PDU support to NUT
...three phase)
and possibly
device.id
device.firmware
device.temperature
* the outlet collection has to be extended with the following data:
outlet.n.current: Current (milliamps RMS)
outlet.n.current.maximum: Maximum seen current (milliamps RMS)
outlet.n.realpower: Current value of real power (Watts)
outlet.n.voltage: Voltage (V)
outlet.n.powerfactor: Power Factor (dimensionless value between
0.00 and 1.00)
outlet.n.power: Apparent power (VA)
- status_{}() needs only to process when device.type=ups
More generally, I think that NUT i...
2012 Aug 30
2
UPS - CYBERPOWER CPS DX600E supported by usbhid-ups
...berPower HID 0.3
driver.version.internal: 0.35
input.transfer.high: 0
input.transfer.low: 0
input.voltage: 230.0
input.voltage.nominal: 230
output.voltage: 239.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 21
ups.mfr: CPS
ups.model: DX600E
ups.productid: 0501
ups.realpower.nominal: 360
ups.status: OL
ups.timer.shutdown: -60
ups.timer.start: 0
ups.vendorid: 0764