2006 Nov 23
2
apcsmart and ambient data (was: NUT and MonAMI plugin)
...t; these include Ganglia, Nagios, KSysguard and a file-logger (amongst
others).
interesting though I've not had time to investigate more.
I've just added a new entry on the client projects page.
Thanks for your work on this point.
> As an aside, I've configured NUT to talk to our APC-8000[3], which comes
with
> an "AP9619" [4] expansion card. This card has an external temperature
probe,
> but it doesn't seem to appear in the variables NUT returns: the UPS's
> internal temperature is mentioned, but no
"ambient.temperature.measured".
&...
2013 Jun 10
2
Best way to add APC and change size of apc.shm_size
Hello!!
I am a new user to puppet and I need to use puppet to install apc and
change the size of apc.shm_size to 64.
I have found a module here: https://github.com/ridonkulous/puppet-apc
However, when I add the module in, it does not work. I get errors on the
puppet code.
Is there a way to just install the apc package normally and just use puppet
code to change ap...
2010 Feb 13
4
UPS connection established, lost, established, etc.
I have an APC Back-UPS CS 500 which connects via USB. I am running NUT
2.4.1 under Karmic amd64. The entry in ups.conf is
[apc]
driver = usbhid-ups
port = auto
desc = "APC Back-UPS CS 500"
I left upsd.conf at the default values, nut.conf is "mode standalone",
and in upsmon.conf, the monitor...
2014 Jul 29
1
APC protocols and drivers (was: Documenting the NUT driver-qualification process)
...Late last week I had to buy a UPS under time pressure. The Eaton unit
>> that thus project gifted me with in 2006(?) died during a severe
>> thunderstorm watch, so it was off to MicroCenter to get a replacement
>> pronto.
>>
>> I wound up buying an APC BN700MC. It was what they had in the
>> performance range I needed. The removable battery door was pleasing.
>>
>
>
>
>> Based on the experience, I have updated the UPS HOWTO:
>>
>> http://www.catb.org/esr/ldp/UPS-HOWTO.html
>>
>>...
2007 Mar 02
1
APC/MGE and NUT support
Hi,
Perhaps as you know it Schneider Electric acquired APC, which involves
the combination of APC and MGE. http://www.apc-mge.com
MGE is an important contributor for NUT with for example Arnaud Quette,
it's does not that the MGE strategy for the free software is stopped by
Schneider Electric or APC.
It is the good moment to make pressure on Schnei...
2005 Dec 23
2
APC regexp match example in newhidups.8
I was testing out newhidups with an APC UPS, and I noticed that I
needed '-x vendor=American.Power.*' instead of '-x vendor=APC.*' as
indicated in the man page.
Do other APC USB UPSes use 'APC' in the vendor string? Should we
sidestep any such problems and just go with the hex vendor ID for APC
examples?
This wa...
2011 Jul 26
5
Problem with upsmon on x64 Windows
...xe, version 0.0.0.0, fault address 0x0000458f.
I try use another server, on 32-bit all is ok. Problem only on x64 platform (maybe in libusb)?
And no different - upsmon master or slave.
C:\Program Files (x86)\NUT\sbin>upsmon.exe -DDDD
Network UPS Tools upsmon 2.6.1-3057:3116M
0.000000 UPS: apc at 192.168.4.8 (slave) (power value 1)
0.015625 Using power down flag file C:\killpower
0.015625 debug level is '4'
0.015625 Trying to connect to UPS [apc at 192.168.4.8]
0.078125 Logged into UPS apc at 192.168.4.8
0.078125 pollups: apc at 192.168.4.8
0...
2009 Nov 19
3
APC BR1500LCD
Hi gang, I have the
APC BR1500LCD [1]
and would like to know if NUT can handle it. The compatibility list
[2] does not show it but I thought that perhaps it would fit in as
some other unit. Does anyone else have this unit?
[1] http://www.apc.com/resource/include/techspec_index.cfm?base_sku=BR1500LCD
[2] http://www.net...
2013 Sep 11
2
New APC "SMT" UPSes support MODBUS, will there be support in NUT?
Hi All,
About a month ago APC announced they were including MODBUS protocol
support in their new APC UPSes. The technical note on this is here:
http://www.apcmedia.com/salestools/MPAO-98KJ7F/MPAO-98KJ7F_R0_EN.pdf
"Application Note #176 Modbus Implementation in APC Smart-UPS"
The APC "announcement" appe...
2017 Apr 26
0
APC Back-UPS XS1300 battery behaviour on test shutdown
Hi there,
Seeing an odd behaviour when running upsmon -c fsd to test my Raspberry Pi
(running Jesse Lite) setup as a upsmon master, attached via USB to an APC
Back-UPS XS1300.
The Raspberry Pi is plugged into the Master outlet on the APC.
The UPS clicks onto battery (and the fan spins up) for a few minutes, then
resets, then repeats again, while finally remaining on AC power afterwards.
The result is that my test ESXi server never quite boots up, befo...
2009 Oct 13
6
USB/UPS connectivity issue on Intel DP55KG Motherboard
Hello,
I use the following in my ups.conf:
# USB:
[apc]
driver = usbhid-ups
port = auto
desc = "APC 1500VA"
pollfreq = 5
On my new motherboard (an Intel DP55KG), every once and awhile I get this:
Broadcast Message from nut at box.com
(somewhere) at 17:48 ...
Communications with UPS apc at localhost lost
Broadcast Mes...
2007 Jan 27
2
"no longer stale" when disconnected with 2.0.5 newhidups
Hello,
I'm using driver newhidups with APC Back-UPS CS 500. Most things works fine
except the following:
After I disconnect the UPS the upsd write "Data for UPS [apc] is stale -
check driver" in /var/log/messages. In the same second it tells "UPS [apc]
data is no longer stale". This repeats all the time the ups is
disco...
2013 Feb 26
1
APC SMX3000RMLV2UNC with AP9631 NUT compatibility via network
I have an APC SMX3000RMLV2UNC UPS, with installed network card model AP9631.
http://www.apc.com/resource/include/techspec_index.cfm?base_sku=SMX3000RMLV2UNC
http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9631
I planned to use network connectivity with this unit and apcupsd, but have not
this...
2013 Sep 13
0
New APC "SMT" UPSes support MODBUS, will there be support in NUT?
Hello Ted,
2013/9/11 Ted Mittelstaedt <tedm at mittelstaedt.us>
> Hi All,
>
> About a month ago APC announced they were including MODBUS protocol
> support in their new APC UPSes. The technical note on this is here:
>
> http://www.apcmedia.com/**salestools/MPAO-98KJ7F/MPAO-**98KJ7F_R0_EN.pdf<http://www.apcmedia.com/salestools/MPAO-98KJ7F/MPAO-98KJ7F_R0_EN.pdf>
>
> "Appl...
2007 Jan 12
2
APC Question...
Greetings:
I've been following through the instructions on how to connect an APC
BackUPS 650 ES to USB, and have it monitored with NUT...
I know my system can SEE the UPS, as DMESG shows this:
hiddev96: USB HID v1.10 Device [APC Back-UPS ES 650 FW:818.w1.D USB FW:w1]
on usb-0000:00:04.2-1
usbcore: registered new driver usbhid
drivers/usb/input/hid-core.c: v2.6:USB HID core dr...
2005 Nov 18
1
APC Matrix 5000 UPS
Hello,
I can get nut to work with this UPS using the apcsmart driver, but only
with limited functionality. It is only reporting the OL/OB status and
that's about it. None of the other useful variables such as run time,
load etc are reported and initiating battery tests does not work either.
Has anyone managed to get nut to report more than thes...
2024 May 24
2
APC SMC1500 question
Hello mailing List.
I manage 2 UPS via NUT, an APC Smart-UPS_1500 and an ?EATON 5S 1500.
I can get load information on the EATON but not on the APC.
Actually upsc doesn?t give much information on the APC.
Does someone know whether this is a driver limitation or a configuration issue ?
Many thanks for your views.
Laurent
PS: my goal is to m...
2024 May 25
1
APC SMC1500 question
d tbsky <tbskyd at gmail.com>
>
> Laurent Taieb via Nut-upsuser
> >
> > Hello mailing List.
> >
> > I manage 2 UPS via NUT, an APC Smart-UPS_1500 and an EATON 5S 1500.
> >
> > I can get load information on the EATON but not on the APC.
> >
> > Actually upsc doesn?t give much information on the APC.
> >
> > Does someone know whether this is a driver limitation or a configuration issue ?
>...
2024 May 25
1
APC SMC1500 question
Thanks d tbsky,
Actually, my nut server is connected via usb. APC looks to be a very common UPS brand.
I wonder whether there is another version of the usbhid server or another server for this UPS ?
Laurent
?Le 25/05/2024 07:00, ? d tbsky ? <tbskyd at gmail.com <mailto:tbskyd at gmail.com>> a ?crit :
d tbsky <tbskyd at gmail.com <mailto:tbsk...
2010 Jun 25
1
Supporting APC 5G UPSs
Hi Guys,
I'd like to submit a patch to enable NUT to communicate with APC 5G UPSs.
The current usbhid-ups driver recognises APC UPSs by the Vendor ID and
Product ID of 0x051D and 0x0002. This needs to be amended with the new
Product ID of 0x0003.
(See attached file: apc-hid.patch)
Secondly, when Nut polls the UPS via the interrupt channel, these will time
out, resulti...