Hi all,
I've finally gotten around to setting up the netbook that controls my 
UPS and I would like to make sure that I've got the metacode correct 
before configuring nut :)
Here's what I've got:
Belkin UPS F6C120auUNV
  * Batteries recently replaced
  * On battery: 24 port switch, PoE AP, antenna power booster, ADSL
    modem, MythTV server, 19" monitor
  * On surge protection: Netbook (details below)
  * I would like the UPS to turn off at 20% battery capacity
Netbook with Debian 7.7.0,
  * Attached via USB to Belkin UPS
  * Battery in netbook lasts three hours, it will outlast the UPS by a
    fair way, so does not need UPS battery supply
  * 'master' where upsd runs
  * runs upsc, upsd, upsmon, upsc, nut-cgi, apache, nagios
MythTV server with Ubuntu 14.04
  * plugged into Belkin UPS
  * to be turned off within 5 minutes of loss of supply
  * to be turned back on after 15 minutes of return of supply (WOL?)
  * 2xSSD drives, 1x4Tb 3.5", 1x250Gb 2.5"
  * 'slave' system
I'm digging through the nut documentation now, I'm sure that I can 
configure nut to do all of this... right?
Thanks,
Greg
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
<http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20141114/409c6679/attachment.html>
Charles Lepple
2014-Nov-17  03:24 UTC
[Nut-upsuser] Belkin UPS, master netbook, slave MythTV server
On Nov 14, 2014, at 6:16 AM, Greg Vickers <daehenoc at iinet.net.au> wrote:> Hi all, > > I've finally gotten around to setting up the netbook that controls my UPS and I would like to make sure that I've got the metacode correct before configuring nut :) > > Here's what I've got: > Belkin UPS F6C120auUNV > Batteries recently replaced > On battery: 24 port switch, PoE AP, antenna power booster, ADSL modem, MythTV server, 19" monitor > On surge protection: Netbook (details below) > I would like the UPS to turn off at 20% battery capacityI'm assuming the "120" means "1200 VA", like this model: http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/Belkin/Universal_UPS_F6C120-UNV.html Depending on the UPS settings, you might be able to use upsrw to directly tell the UPS to shut off at 20%, or you might need the "ignorelb" flag: http://www.networkupstools.org/docs/man/ups.conf.html> Netbook with Debian 7.7.0, > Attached via USB to Belkin UPS > Battery in netbook lasts three hours, it will outlast the UPS by a fair way, so does not need UPS battery supply > ?master? where upsd runs > runs upsc, upsd, upsmon, upsc, nut-cgi, apache, nagiosSeems reasonable. One question which you may have already answered: what if the UPS battery gets to 20% and upsmon signals a shutdown - how does the netbook know how to turn back on later? If the netbook doesn't have a way to boot back up automatically when the power comes back, you might be able to find a cheap SBC or WiFi router with a USB port, that can run NUT and act as the master. (A few people have discussed using a Raspberry Pi for this.)> MythTV server with Ubuntu 14.04 > plugged into Belkin UPS > to be turned off within 5 minutes of loss of supply > to be turned back on after 15 minutes of return of supply (WOL?) > 2xSSD drives, 1x4Tb 3.5?, 1x250Gb 2.5? > ?slave? system > I'm digging through the nut documentation now, I'm sure that I can configure nut to do all of this... right?I think you want upsmon to trigger upssched for the "off after 5 minutes" requirement. I don't use upssched myself; hopefully someone else can offer help if needed. If nothing else, we do have source code :-) The soft shutdown/WOL part seems possible. -- Charles Lepple clepple at gmail -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20141116/451ca008/attachment.html>