2006-Mar-15 05:22 UTC
[Nut-upsdev] APC Smart-UPS 1000 RM USB problems with newhidups
Well, after our first real extended power outage, I found out that even though the UPS 1000 RM is recognized okay, it does not work properly. It never seems to see any change in UPS status. It looks very similar to the other issue I reported with the APC CyberFort 350. I never was able to get to the bottom of the CyberFort issue, but I'll bet it's the same issue as we have with the APC 1000 RM. Here's what I have done so far: * Machine is a AMD Athlon, running current Debian stable, 2.4.27 stock Debian kernel * Machine has been verified working with a few APC BackUPS models with newhidups 1) Tested by unplugging the power, right after a fresh boot. -- Newhidups didn't see any change at all 2) Restarted the driver without rebooting. -- Still said the UPS was online 3) Stopped the driver, un/replugged the USB cable, restarted driver. -- Newhidups saw that it was OB 4) Plugged in UPS power cable. -- Newhidups saw battery level going up, but still saw OB Then, I decided to try on my Toshiba Centrino laptop, running Fedora Core 4, stock 2.6.11 Fedora kernel. I started just newhidups with -DD without upsd or upsmon. It did notice all the UPS events and battery level changing, but segfaulted after a couple minutes. Does anyone have any ideas here? George, I'm also wondering what kernel you're running on the box you have attached to your SmartUPS 1000 RM.
George Ross
2006-Mar-15 09:22 UTC
[Nut-upsdev] APC Smart-UPS 1000 RM USB problems with newhidups
> Does anyone have any ideas here? George, I'm also wondering what kernel > you're running on the box you have attached to your SmartUPS 1000 RM.2.6.12-1.1381_FC3 on Dell PE650 and PE750. I don't have time to run one down right now, but I've just tried pulling the plug and newhidups did go "on battery" and then back "on line" again. Our load graphs seem to be unbroken for at least the last couple of weeks. -- Dr George D M Ross, School of Informatics, University of Edinburgh Kings Buildings, Mayfield Road, Edinburgh, Scotland, EH9 3JZ Mail: gdmr@inf.ed.ac.uk Voice: +44 131 650 5147 Fax: +44 131 667 7209 PGP: 1024D/AD758CC5 B91E D430 1E0D 5883 EF6A 426C B676 5C2B AD75 8CC5 -------------- next part -------------- A non-text attachment was scrubbed... Name: not available Type: application/pgp-signature Size: 239 bytes Desc: not available Url : http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20060315/9b976ae3/attachment.pgp
Justin Maggard
2006-Mar-16 02:24 UTC
[Nut-upsdev] APC Smart-UPS 1000 RM USB problems with newhidups
I was able to do a little more testing today. I hooked up the UPS to another Linux FC4 box, running the newest stock Fedora kernel, 2.6.14-1.1656_FC4. I checked out the latest nut Development code from CVS; patched upsdrvctl.c so it will compile; and patched libusb.c to shorten desc->wDescriptorLength to 1040 if it is reported as 61939 (needed for 1000 RM). I set up the config files, and started newhidups and upsd. I then pulled the power cord before running a little loop to monitor ups status using upsc. Pretty soon after pulling the cord, newhidups died. So, 2.6 behavior is not much better than 2.4. Also, I did try the old hidups driver after newhidups died, and it worked fine except for the fact that it started adding an extra "0" to the end of the battery.charge line in upsc for some reason. Here is output from the shell running the while loop using newhidups: --- Pulled the power cord before starting typing --- [root@FC4 clients]# while true; do ./upsc UPS@localhost|egrep '^battery.charge:|^battery.runtime:|^ups.status:'; sleep 10; done battery.charge: 100 battery.runtime: 5280 ups.status: OL battery.charge: 100 battery.runtime: 5280 ups.status: OL battery.charge: 100 battery.runtime: 5280 ups.status: OL battery.charge: 100 battery.runtime: 5280 ups.status: OL battery.charge: 100 battery.runtime: 4980 ups.status: OL battery.charge: 100 battery.runtime: 4980 ups.status: OL battery.charge: 100 battery.runtime: 4980 ups.status: OL battery.charge: 100 battery.runtime: 4980 ups.status: OB DISCHRG battery.charge: 100 battery.runtime: 4800 ups.status: OB DISCHRG Error: Driver not connected Error: Driver not connected Error: Driver not connected>Well, after our first real extended power outage, I found out that even >though the UPS 1000 RM is recognized okay, it does not work properly. It >never seems to see any change in UPS status. It looks very similar to the >other issue I reported with the APC CyberFort 350. I never was able to get >to the bottom of the CyberFort issue, but I'll bet it's the same issue as >we have with the APC 1000 RM. Here's what I have done so far: >* Machine is a AMD Athlon, running current Debian stable, 2.4.27 stock >Debian kernel >* Machine has been verified working with a few APC BackUPS models with >newhidups >1) Tested by unplugging the power, right after a fresh boot. -- >Newhidups didn't see any change at all >2) Restarted the driver without rebooting. -- Still said the UPS was >online >3) Stopped the driver, un/replugged the USB cable, restarted driver. -- >Newhidups saw that it was OB >4) Plugged in UPS power cable. -- Newhidups saw battery level going up, >but still saw OB > >Then, I decided to try on my Toshiba Centrino laptop, running Fedora Core >4, stock 2.6.11 Fedora kernel. I started just newhidups with -DD without >upsd or upsmon. It did notice all the UPS events and battery level >changing, but segfaulted after a couple minutes. > >Does anyone have any ideas here? George, I'm also wondering what kernel >you're running on the box you have attached to your SmartUPS 1000 RM. > > > >_______________________________________________ >Nut-upsdev mailing list >Nut-upsdev@lists.alioth.debian.org >http://lists.alioth.debian.org/mailman/listinfo/nut-upsdev
Peter Selinger
2006-Mar-16 15:52 UTC
[Nut-upsdev] APC Smart-UPS 1000 RM USB problems with newhidups
I'm on vacation. The bugs you are reporting sound serious; I'll investigate after I get back home, in late March at the earliest. Greetings from Kerman, Iran, -- Peter Justin Maggard wrote:> > Well, after our first real extended power outage, I found out that even > though the UPS 1000 RM is recognized okay, it does not work properly. It > never seems to see any change in UPS status. It looks very similar to the > other issue I reported with the APC CyberFort 350. I never was able to get > to the bottom of the CyberFort issue, but I'll bet it's the same issue as we > have with the APC 1000 RM. Here's what I have done so far: > * Machine is a AMD Athlon, running current Debian stable, 2.4.27 stock > Debian kernel > * Machine has been verified working with a few APC BackUPS models with > newhidups > 1) Tested by unplugging the power, right after a fresh boot. -- Newhidups > didn't see any change at all > 2) Restarted the driver without rebooting. -- Still said the UPS was > online > 3) Stopped the driver, un/replugged the USB cable, restarted driver. -- > Newhidups saw that it was OB > 4) Plugged in UPS power cable. -- Newhidups saw battery level going up, > but still saw OB > > Then, I decided to try on my Toshiba Centrino laptop, running Fedora Core 4, > stock 2.6.11 Fedora kernel. I started just newhidups with -DD without upsd > or upsmon. It did notice all the UPS events and battery level changing, but > segfaulted after a couple minutes. > > Does anyone have any ideas here? George, I'm also wondering what kernel > you're running on the box you have attached to your SmartUPS 1000 RM. > >