Peter, Just to let you know that I have done all my tests with the latest development stuff (Oct 3 23:46 to be specific, with NO local patches!), and everything turned out fine except for the cleaning up of ups.status: as presented by upsc that I reported earlier. I suspect that that cleanup is generic to newhidups, because a couple of month ago Arnaud made some changes for cleaning up LB with OL once the battery is adequately charged, a problem that looks rather similar to me. I will now think about the documentation issue that you suggested, although right now I have no idea what to do! Thanks again for your work, AG -- ---------------------------------------------------------------------- Alfred Ganz alfred-ganz@agci.com AG Consulting, Inc. (203) 624-9667 440 Prospect Street # 11 New Haven, CT 06511 ----------------------------------------------------------------------
Alfred Ganz wrote:> > Peter, > > Just to let you know that I have done all my tests with the latest > development stuff (Oct 3 23:46 to be specific, with NO local patches!), > and everything turned out fineExcellent.> except for the cleaning up of ups.status: > as presented by upsc that I reported earlier. I suspect that that cleanup > is generic to newhidups, because a couple of month ago Arnaud made some > changes for cleaning up LB with OL once the battery is adequately > charged, a problem that looks rather similar to me.I don't know. It is normal for some UPSs to show "OL CHRG" even when the battery is full. About "OL DISCHRG", I am not so sure. I know the status info usually comes directly from the UPS, so it might not be a driver issue at all, but I don't know.> I will now think about the documentation issue that you suggested, > although right now I have no idea what to do!Great! -- Peter