On Thu, Jul 12, 2012 at 02:09:12PM +0400, Anton Nikiforov
wrote:> Dear All,
>
> I have problem with setting up migration on Intel Multi-Flex server.
> The problem is that SAS controller IDs (and volume ids in
> /dev/disk/by-path directory) are different between nodes.
>
> For example on node0 i have:
> lrwxrwxrwx 1 root root 9 Jun 29 07:20
> pci-0000:04:00.0-sas-0x500015500002040a-lun-0 -> ../../sda
> lrwxrwxrwx 1 root root 10 May 27 09:17
> pci-0000:04:00.0-sas-0x500015500002040a-lun-0-part1 -> ../../sda1
> .......
>
> On node1 i have:
> lrwxrwxrwx 1 root root 9 Jul 12 21:19
> /dev/disk/by-path/pci-0000:04:00.0-sas-0x5000155000020409-lun-0 ->
> ../../sda
> lrwxrwxrwx 1 root root 10 Jul 12 21:19
> /dev/disk/by-path/pci-0000:04:00.0-sas-0x5000155000020409-lun-0-part1
> -> ../../sda1
> ........
>
> Difference is in 0x500015500002040a and 0x5000155000020409
> But this is the matter of migration falure because migration script
> cannot find needed volume.
>
> Is there any chance to fix it somehow?
Have you tried using /dev/disk/by-id/ aliases instead ? IIRC, those are
based on the SCSI volume WWID which should be stable across any host
seeing the LUN
Daniel
--
|: http://berrange.com -o- http://www.flickr.com/photos/dberrange/ :|
|: http://libvirt.org -o- http://virt-manager.org :|
|: http://autobuild.org -o- http://search.cpan.org/~danberr/ :|
|: http://entangle-photo.org -o- http://live.gnome.org/gtk-vnc :|