Eric Bishop
2007-Apr-11 04:16 UTC
[asterisk-users] Purposely setting red alarm on PRI for testing purposes
Does anyone know if is possible to purposely set red alarm status on PRI circuit for testing purposes (other than unplugging it). I have looked for a console command which might allow this.... -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20070411/985e8e64/attachment.htm
Alex Balashov
2007-Apr-11 07:17 UTC
[asterisk-users] Purposely setting red alarm on PRI for testing purposes
On Wed, 11 Apr 2007, Eric Bishop said something to this effect:> Does anyone know if is possible to purposely set red alarm status on PRI > circuit for testing purposes (other than unplugging it). I have looked for a > console command which might allow this....That depends on the equipment into which it is terminated. :-) If the T1 dumps into an offboard CSU/DSU, you can loop back the network side toward the telco which will cause an alarm to be perceived on the DTE side. Most T1 cards and T1 interfaces with integrated CSU/DSUs will allow you to do something similar for testing, which will have the effect of putting the interface into the same state it would be in if you unplugged it. Are you bringing this PRI into a Digium PRI card? -- Alex -- Alex Balashov <sasha@presidium.org>