similar to: AVR750U Low Power not Triggering Shutdown

Displaying 20 results from an estimated 3000 matches similar to: "AVR750U Low Power not Triggering Shutdown"

2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
I have a Tripp-Lite BCPERS450, connected to a system running Ubuntu 16.04.3 LTS and NUT 2.7.2-4ubuntu1.2. I had to make my own /lib/systemd/system-shutdown/nutshutdown, but now everything is working except for powering on and off the UPS. Regardless of the settings of offdelay and ondelay in upsconf, and regardless of whether the AC power is on, when I say "upsdrvctl shutdown" the UPS
2007 Feb 26
1
Tripp Lite USB UPS
Hello all, About a month ago Peter and Charles were kind enough to try to help me with getting a Tripp Lite USB UPS to work with NUT. I reported quite a bit of initial success, and then other things here fell apart. Between work, fence building and a week-long out of town business trip, I have had to drop this from my list of things to do lately. I am back at it, and I believe I will have
2016 May 04
2
New UPS Support: Eaton 5S 1000
Charles, It starts out good, then goes into a Connection timed out loop. If I can provide any information to fix a driver I'll do my best. Here's the output: # /usr/local/ups/bin/usbhid-ups -DD -a eaton Network UPS Tools - Generic HID driver 0.41 (2.7.4) USB communication driver 0.33 0.000000 debug level is '2' 0.002550 upsdrv_initups... 0.288229 Checking device
2006 Nov 15
1
Tripp Lite OMNI900LCD
I am having an issue running NUT and using an TrippLite OMNI900LCD. When I run ./upsdrvctl start I get : [player@V0002-S002 bin]$./upsdrvctl start Network UPS Tools - UPS driver controller 2.1.0 Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 (2.1.0) Detected a UPS: Tripp Lite /TRIPP LITE UPS Using subdriver: TrippLite HID 0.1 (experimental) dstate_setflags: base variable
2007 Dec 05
2
Crash when I start driver
It's been a while since I tried to use NUT, so I thought I would give it another try. Big trouble. The UPS is a Tripp-Lite AVR 550U. It has only a USB connector. The computer is running Red Hat Enterprise Linux 4. I just installed NUT version 2.2.0. I'm going through the steps in the INSTALL document. # cat ups.conf [igor] driver = usbhid-ups port = auto
2010 Feb 18
2
HP R1500 G2 UPS
Hi, I have a HP R1500 G2 UPS and want to get it working under Debian Lenny - as this OS is not supported by HP I'm trying to use nut for it - but I can't get it working. Do I have any chance to get the UPS running with nut. I also tried different drivers but had no luck either. Or does anyone has experience with HP UPS under debian ? Any help would be nice ! I tried /lib/nut/usbhid-ups
2012 Jul 18
1
Problem connecting to eaton ups. No matching HID UPS found. Driver failed to start(exit status=1)
Hi! Info OS: TinyCore Linux 4.5.6 NUT version: 2.6.4 NUT innstallation method: source tarball Device name: Eaton Ellipse ups eco 1600 usb din (EL1600USBDIN) /usr/local/ups/etc/ups.conf file: [eaton] driver = usbhid-ups port = auto When I run: root at Dalen:/usr/local/ups/bin/upsdrvctl start eaton I get this error message: Network UPS Tools - UPS driver controller 2.6.4
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help. From: Charles Lepple <clepple at gmail.com> Date: Mon, 18 Dec 2017 19:26:56 -0500 This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally: What was the largest
2018 May 25
1
[HCL] IBM 1500VA/1000W Tower HV UPS supported by usbhid-ups
Hi I would like to be able to use this UPS with NUT please ? Product id = 53962KX Network UPS Tools - Generic HID driver 0.38 (2.7.2) USB communication driver 0.32 0.000000 debug level is '2' 0.002761 upsdrv_initups... 0.014996 Checking device (03F0/0024) (001/005) 0.032670 - VendorID: 03f0 0.032790 - ProductID: 0024 0.032955 - Manufacturer:
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi, This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status. Details of our installation are: OS: Debian 6 NUT version: 2.7.4 Installation method: from source tarball UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in
2008 Dec 31
2
Unknown product ID for Tripp-Lite UPS (SU1500RTXL2UA)
To all, I attempted to configure the UPS tools for the Tripp-Lite SmartOnline 1500VA 2U rackmount UPS. I followed the instructions from the 'upsdrvctl start' output and posted the diagnostic information below. Is my UPS using an unknown product ID as reported? From the mailing list archive, I have found another posting for the same UPS with device model '09AE/4003', whereas
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Thanks for the quick response! On Sat, Jun 27, 2020, at 22:17, Manuel Wolfshant wrote: > On 6/28/20 4:25 AM, Scott Colby wrote: > > Hello, > > > > I am having difficulty using NUT to shut down my Netgate SG-1100 > > (a pfSense router) when the power level of the UPS gets critically > > low. > > > > Here is some relevant information: > > - OS:
2013 Aug 07
4
HP R1500 G3 problems
Hi there, OS: (L)ubuntu 12.04 precise LTS Nut: 2.6.3-1ubuntu1.1 Installation Method: Package (apt-get install nut) Hardware: HP R1500 G3 INT Hardware-Specs: http://h18004.www1.hp.com/products/quickspecs/14059_div/14059_div.pdf Problem: I tried to set up nut with our new arrived HP R1500 G3 UPS but there is a failure with the usb connection. After trying "/lib/nut/usbhid-ups -DD -a
2019 Dec 08
3
Tripp Lite SMART1500LCD repeatedly disconnecting and reconnecting
My UPS is connected to a Raspberry Pi by USB. After a few hours of working, the service fails. Looking at kernel messages I noticed that the device is repeatedly disconnecting and reconnecting. I have tried using a different USB port and using a brand new USB cable. I have not had success by changing config parameters like pollfreq/pollinterval/etc. What is causing the UPS to keep disconnecting?
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
I tested your fix (newhidups -DDD /dev/null) using both and APC Back-UPS 350 an APC Smart-UPS RT 2000 XL. No more segmentation fault due to the fixed-size array. ~Jacob -----Original Message----- From: nut-upsdev-bounces@lists.alioth.debian.org [mailto:nut-upsdev-bounces@lists.alioth.debian.org] On Behalf Of Peter Selinger Sent: Monday, October 16, 2006 12:12 PM To: Schmier, Jacob Cc: NUT
2020 Jan 01
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
When running 'sudo upsmon -c fsd' UPS turns off then back on after a delay as expected. But when power is disconnected and the command is ran, the UPS turns off but still turns back on again. Changing 'ondelay' to -1 or 0 does not change the behavior. How can I get the UPS load to stay turned off if there is no power? Or am I misunderstanding how to test this functionality?
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
On Jun 10, 2019, at 2:32 PM, Marc Finns wrote: > > Hello, I read all FAQ and other sources but I could not find this situation, so I thought of asking the experts. > I successfully configured a Raspberry NUT server to control my UPS that powers several devices (NUC with ESXI VMs, Synology NAS etc). > All works well in principle, but I have the following behaviours that I could not
2015 Mar 03
0
Ippon Smart Winner 3000 New
Hello, I've recently bought Ippon Smart Winner 3000 New (note the "New" in the model name) and I can't make NUT to work with it. Linux gateway 3.17.8-gentoo-r1 #1 SMP Mon Feb 16 13:46:11 MSK 2015 x86_64 Intel(R) Celeron(R) CPU 1037U @ 1.80GHz GenuineIntel GNU/Linux Network UPS Tools 2.7.2 1) USB connection partially works using usbhid-ups driver, the problem is that I
2017 Aug 21
5
TrippLite SMART1500LCD no delay before ups shutdown.
Hello, I am hoping someone can point me in the right direction. I am setting up a new UPS, most things seem to be working except the UPS turns off immediately during a test shutdown using///"//upsmon -c fsd".//No delay before the UPS turns itself off leaving no time for the server to shutdown properly. I have attempted to set the delay higher using "upsrw -s
2015 Aug 15
2
Small patch to scale the values for TRIPP-LITE SMART*LCDT's
Hi, I just decided to fix some scaling issues for my UPS (TRIPP-LITE SMART1500LCDT). Apparently that issue existed for some time (and I knew about it as well:-() See http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 for a thread. My little patch is attached (against 2.7.3). It seems to be working better for me but I don't have any other TRIPP-LITE's to test that I did