Displaying 20 results from an estimated 90 matches similar to: "[HCL] CyberPower EC350G supported by usbhid-ups"
2024 Jan 13
1
Cyber Power LE1000DG UPS
I have a Cyber Power LE1000DG UPS I got from Best Buy this weekend. I plan to use it with a TrueNAS scale system, and it is connected via USB. Vendor link: https://www.cyberpowersystems.com/product/ups/battery-backup/le1000dg/.
TrueNAS has you pick a UPS driver. I could not find any "LE" related models on https://networkupstools.org/stable-hcl.html (which is the list TrueNAS uses). Per
2020 Oct 21
1
Can't get CyberPower UPS to work with Raspberry Pi 4
I've searched the listserv archive, to no avail, so I hope I'm not
duplicating a previous problem. I am anxious to get this working, so I'm
open to uninstalling what I have and starting over.
One note which may not be meaningful is that this UPS pre-dates the
Raspberry Pi I've got connected to it, and I used to use it with the
CyberPower software, which requires logging in with a
2006 May 07
3
Yet another HID device - Cyberpower AE550
Hope it's not too rude to just drop this here for y'all...
Checking device (0764/0501) (001/005)
- VendorID: 0764
- ProductID: 0501
- Manufacturer: CPS
- Product: UPS AE550
- Serial Number: unknown
This one and their 485 don't provide a load measurement -- the Windows drivers kick it onto battery for a timed period and measure the drain to guess the runtime -- apparently all their
2012 May 28
1
[HCL] Cyber Power Systems CP1000PFCLCD supported by usbhid-ups
Cyber Power Systems CP1000PFCLCD
= upsc output =
attached
= Shutdown results =
I experienced a genuine power outage shortly after setup. The 1 master
system and the 1 slave system both shutdown successfully. The master
shutdown before the slave (*not* a bug report; I may not have this
configured correctly yet). The UPS was not powered off by the master. I
don't know if the UPS
2012 Feb 22
1
[HCL] CyberPower OR700 supported by usbhid-ups
CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html)
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 6000
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 14.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS OR700
2020 Oct 31
2
ups.test.result meaning
Hi folks, new to list...
nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD.
After performing upscmd cp1350 at localhost test.battery.start.quick the
result was "Done and warning". I searched through syslog but could find no
additional information.
What is the warning?
Battery charge was 100% before test was performed.
Here's the full output from upsc after test:
2012 Apr 26
1
[HCL] CyberPower Systems PR6000LCDRTXL5U supported by usbhid-ups
CyberPower Systems PR6000LCDRTXL5U
http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/pp-series/PR6000LCDRTXL5U.html
I had to create the following udev rule (on RHEL6):
ATTR{idVendor}=="0764", ATTR{idProduct}=="0601", MODE="664", GROUP="dialout"
Shutdown testing successful. UPS comes back online after turning off.
# upsc
battery.charge:
2020 Oct 25
4
Can't get CyberPower UPS to work with Raspberry Pi 4
This was very helpful for me, thank you!
On Sat, Oct 24, 2020 at 9:06 AM Charles Lepple <clepple at gmail.com> wrote:
> The easiest way to tell if upsd is working is to run "upsc -l" on the same
> system, which will list the NUT UPS names, and then run e.g. "upsc mge"
> (replacing "mge" with the name returned by "upsc -l")
>
Here was the
2009 Jul 28
4
Patch for drivers.list
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Just a little patch for the drivers.list
The "Cyber Power Systems Intelligent Series CP1500EAVRLCD" ups
http://eu.cyberpowersystems.com/products/ups_systems/intelligent/cp1500eavrlcd.htm
Got one here running (see:
https://nut.stillbilde.net/cgi-bin/nut/upsstats.cgi?host=CyberPower at upsmonitor)
Works flawlessly.
Patch as follows:
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
CyberPower Battery Backup with Surge Protection, model LE825G
Appears to function properly with the driver listed on the HCL for the
Cyber Power Systems ups 2 685AVR USB (usbhid-ups).
Tested with shutdown mode "UPS Goes On Battery" with a 5 second timer
and the system successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
Cyber Power Systems CP600LCD
https://www.cyberpowersystems.com/product/ups/cp600lcd/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP600
device.type: ups
driver.name: usbhid-ups
2019 Mar 06
0
HCL Cyberpower CPS-850AVRLCD supported by usbhid
Cyberpower CPS850avrlcd
https://www.cyberpowersystems.com/product/ups/cp850avrlcd/
shutdown sequence: UNTESTED
upsc output:
_____
sudo upsc cp-ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1230
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS
2020 Oct 31
0
ups.test.result meaning
I'm going to guess that since your test runtime of 305 is very close to the low limit of 300, that's the warning. Not yet a fail, but very, very close.
On October 31, 2020 11:41:39 AM CDT, Rick Dicaire <kritek at gmail.com> wrote:
>Hi folks, new to list...
>nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD.
>
>After performing upscmd cp1350 at localhost
2020 Oct 26
0
Can't get CyberPower UPS to work with Raspberry Pi 4
On Oct 25, 2020, at 11:52 AM, Robert Stocker <kneadtoknow at gmail.com> wrote:
>
> Init SSL without certificate database
> battery.charge: 100
> battery.charge.low: 10
> battery.charge.warning: 20
> battery.mfr.date: CPS
> battery.runtime: 15690
> battery.runtime.low: 300
> battery.type: PbAcid
> battery.voltage: 24.0
> battery.voltage.nominal: 24
I
2011 Mar 31
1
Startup timing issue with CyberPower CP425HG UPS
Hi all -
I'm running into a small problem with the CyberPower CP425HG UPS and NUT 2.4 on Fedora 11.
For whatever reason, at system startup this UPS registers as a USB device very late in the boot process, *after* all the services have started. So at boot up when the "ups" service in init.d tries to start "upsdrvctl", it fails because no USB UPS device cannot be found.
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U
https://www.cyberpowersystems.com/product/ups/avrg750u/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 15360
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: AVRG750U
device.serial: <REDACTED>
device.type: ups
2003 Mar 10
2
AOL on Linux
Hello. I am a newbie to wine. In my local area, the only way to have unmetered access to th internet is to use AOL. After some research on the internet, it gas come to light that some linux users have managed to install AOL's version 5.0 of their software to access AOL.
Following these instructions, AOL5 is installed on my computer. The command "wine setup32.exe" was run. AOL5
2024 Apr 23
1
CyberPower CST150UC: Question re: battery.runtime.low configuration settings
I would like to solicit some feedback re: the
battery.runtime.lowconfiguration settings through NUT. I was able to set
the value using the 'upsrw' command but when I did a 'upsc' the
configuration seems incorrect. Please see below for details. Thank you
OS name and version:
?? ?Description:??? Debian GNU/Linux 12 (bookworm)
?? ?Release:??????? 12
?? ?Codename:?????? bookworm
2015 Jan 21
2
CyberPower BR850ELCD ignores offdelay and turns itself back on while still on battery
Hi there,
I just purchased a CyberPower BR850ELCD and while setting NUT up with
the install instructions from the homepage was pretty straightforward,
and the UPS was detected by the usbhid-ups driver, I'm having problems
getting the UPS to work properly.
First issue: whatever I set as the offdelay, seems to be ignored and the
UPS just cuts the power about 2sec after receiving the
2016 Dec 08
2
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
I didn't want to sign up for the nut-devs list or create a git account
just to provide this information, so I hope posting this info here is OK...
I just bought a Cyber Power Systems EC750G UPS for use as a spare. Here
are some info for it:
=========================
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: