Displaying 20 results from an estimated 600 matches similar to: "N-Power MEV-3000LT compatibility report and problem"
2013 Aug 11
2
N-Power MEV-3000LT compatibility report and problem
On Aug 11, 2013, at 2:12 PM, ????????? ???????? wrote:
> I see no problem with how the device communicates the Blazer/Megatec protocol.
> I must have found a bug in the driver.
It is possible that the shutdown was tested with a different implementation of the protocol. What do you get from the "I" command?
On Aug 11, 2013, at 11:25 AM, ????????? ???????? wrote:
> So I
2013 Aug 11
0
N-Power MEV-3000LT compatibility report and problem
Hello,
sorry for messing up the things. I mean many copies of the same text
in my previous message and mixing up the command names, it turned
out that I forgot the protocol details after so many years.
I found my records, connected a serial terminal to the UPS and found
that the device itself works as expected so my problem cannot be
explained with device incompatibility.
Below is excerpt from
2013 Aug 11
1
N-Power MEV-3000LT compatibility report and problem
Hello,
the code below the failing part mentions this flavor of protocol, drivers/blazer_ser.c:463
/*
* If a command is invalid, it will be echoed back.
* As an exception, Best UPS units will report "ACK" in case of success!
*/
I prepared a patch, it adds a similar check and also checks (in both occurencies) for
blazer_command()<0, the latter
2013 Aug 11
0
N-Power MEV-3000LT compatibility report and problem
Hello,
> What do you get from the "I" command?
A string of 8 spaces.
>> So I believe the compatibility list deserves two new lines.
>
>Probably best to delay adding this to the HCL until we can get the driver to shut down the UPS properly.
I debugged the problem. From the source, drivers/blazer.c:418
/*
* If a command is invalid, it
2014 Apr 29
1
blazer_ser battery.high / battery.low
Hello list,
we've got a PowerWalker VI 1000E/RT LCD UPS and like to use it with NUT
using the blazer_ser driver.
For the blazer_ser driver to display percentage, one has to add
battery.voltage.high and battery.voltage.low voltages to the ups config.
Here's what I received from the powerwalker customer service:
Battery-Low Voltage: 21.6VDC
Battery Shutdown: 19.2VDC
Now my questions:
1.
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Hello
First things first, thanks for great work with NUT.
For years I used Informer compact 3kVA UPS
http://www.informups.com/informer_compact.html with nut/megatec serial
driver, but it stopped working when I switched to blazer_ser with
2.6.0 upgrade.
I'm using 2.6.0 on gentoo.
Blazer_ser seems to connect with UPS, but upsmon reports driver not connected.
uname -a
Linux localhost
2014 May 04
1
blazer_ser: UPS behind seriell ethernet converter
Hi,
I'm trying to get an Effekta UPS (works directly with blazer_ser) working
behind a seriell to ethernet converter (Brainboxes ES-246).
I've set the converter to 2400 baud, 8N1, no flow control. On the linux side I
started socat and blazer_ser. All I got are timeouts after 12 seconds. I can
see network traffic with tcpdump but I've no idea what to do to get this
working.
Does
2018 Jan 25
0
HCL Zinto 800 supported by blazer_ser and blazer_usb
Hi,
today I have tested the Zinto 800 with blazer_ser and blazer_usb on
Citrix Server 7.0. Both works fine.
upsc-Output (blazer_ser):
battery.charge: 94
battery.voltage: 25.70
battery.voltage.high: 26.00
battery.voltage.low: 20.80
battery.voltage.nominal: 24.0
device.mfr:
device.model: ZINTO 800
device.type: ups
driver.name: blazer_ser
driver.parameter.pollinterval: 2
driver.parameter.port:
2012 Nov 17
1
[HCL] Aviem Power RT 1000-3000VA supported by blazer_ser
Manufacturer: Aviem Power RT 1000-3000VA
Description: Rack/Tower Intelligent Online LCD UPS.
connected with serial cable.
#upsc
battery.voltage: 24.96
battery.voltage.low: 21.5
battery.voltage.nominal: 24.0
beeper.status: enabled
device.mfr:
device.model:
device.type: ups
driver.name: blazer_ser
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ttyUSB1
driver.version: 2.6.3
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi,
I have a bunch of UPSs, most connected to pcs with Linux working 100% with
NUT.
The only one I have a problem with, is connected to Windows 7 64bit, and I
used the straight MSI installed from the website
named NUT-Installer-2.6.5-4.msi
Took me a while to find a way to get it to work, but it is ugly for now.
Just starting up the service results in a NUT not working at all, and I
tracked it
2015 Feb 10
2
[HCL] Artronic art 1000 bl supported by blazer_ser
Hi Artronic art 1000 bl is supported partially by blazer_ser:
battery.voltage: 13.40battery.voltage.nominal: 12.0
beeper.status: enabled
device.type: ups
driver.name: blazer_ser
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ttyS0
driver.version: 2.6.3
driver.version.internal: 1.51
input.current.nominal: 4.0
input.frequency: 50.1
input.frequency.nominal: 50
input.voltage: 232.9
2010 Dec 02
1
(no subject)
I am have a nice result whith blazer_ser driver! respect!
# ./nut start
Network UPS Tools - UPS driver controller 2.4.1
Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.4.1)
Supported UPS detected with megatec protocol
Vendor information read in 1 tries
Battery runtime will not be calculated (runtimecal not set)
<================= !!!
Starting nut.
Network UPS Tools upsd 2.4.1
2011 Aug 26
1
Unsupported UPS Orvaldi 520PL?
Hello,
I am new to UPS stuff, please be patient with me ;-)
Archlinux i686, kernel 3.0-ARCH #1 SMP PREEMPT.
nut 2.6.1 installed from source via Arch's AUR repository.
Mother board GA D525TUD with two serial ports, both enabled in BIOS.
I got some old Orvaldi 520 PL UPS [1], which is supposed to be
supported by the vendor [2] with sw called UPSmart. The statically
compiled i386 binary ran
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
Hello all,
long time away from this list, glad to be around again!
I have this Powercom Vanguard VGN VGD-20K31. Some details of this model:
* 3-phase input, single phase output
* Model has 240V / 12V9AH x 20 x 2SET, plus another set of 20 batteries.
All in all, 3 sets
* Serial connection to Windows 2k3 server with UPSMon
Now I was strongly considering replacing the bundled no-good upsmoon
2020 Jul 07
2
New UPS to the DB
Hi, I have an OEM of KStar UDC9101S which is Megatec protocol rs232 capable
unit.
So I use blazer_ser protocol=megatec /dev/ttyUSB0 with no issue to get NUT
running.
Please direct me what command should I issue to collect the data in order
to include the UPS to device database?
P.S. tryed /lib/nut/blazer_ser -DD... but no difference from a regular
output has being added by the driver.
2014 Feb 19
0
nut driver for SMS (brazil) UPS
Hi Charles,
I'll try the blazer_ser and the nutdrv_qx with version 2.7.1 later.
Below, the result of 'lsusb -vvv' requested:
Bus 004 Device 002: ID 04b4:5500 Cypress Semiconductor Corp. HID->COM RS232
Adapter
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 1.00
bDeviceClass 0 (Defined at Interface level)
2015 Nov 19
2
Contact-closure UPS
Hi Charles,
I am done with few things:
I made the cable - looks good, because I see some activities.
I upgraded NUT to 2.7.3.
but I have no success to start driver(this are the outputs)
nut.cfg
MODE = netserver
ups.conf
[infosec]
driver = nutdrv_qx (or blazer_ser)
port = /dev/ttyS1
desc = "XP Pro 2500 RM"
output(nutdrv_qx cmd upsdrvctl -DDD start)
Network UPS
2014 Jun 02
0
blazer_ser battery.high / battery.low
On Jun 2, 2014, at 12:25 PM, Andreas Lausch / TBT wrote:
>
> Hi,
>
> thanks for the reply.
>
> On 2014-05-29 05:21, Charles Lepple wrote:
>>> Now my questions:
>>> 1. should the blazer_ser's high voltage be the voltage during charging
>>> or right after I've unplugged it from the mains?
>> sounds like during charging (or more
2012 Jun 09
3
[HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
The REDi Blazer 600VA (BLAZER600c) UPS found here [ro_RO]:
http://www.emag.ro/ups-redi-blazer-600va-blazer600c/pd/EX5X2BBBM/
which is actually a Centralion Blazer 600VA [en_TW]:
http://www.centralion.com/html/product/back-Product-ups-blazer400.htm
works with the blazer_ser driver
----------shell output----------
# upsrw ups
# upscmd -l ups
Instant commands supported on UPS [ups]:
beeper.toggle -
2015 Nov 16
2
Contact-closure UPS
Hi Charles,
>----- Original Message -----
>From: "Charles Lepple" <clepple at gmail.com>
>To: "R?bert SZAKSZ" <robert at szaksz.eu>
>Cc: nut-upsuser at lists.alioth.debian.org
>Sent: Monday, November 16, 2015 3:20:17 PM
>Subject: Re: [Nut-upsuser] Contact-closure UPS
>
>[please use reply-all when responding - the list does not modify the