2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the
manufacturer's PowerChute software and smart signaling, so I have
decided to try NUT. The smartups driver can't make contact through
the serial port.
Since this is rack-mounted, it comes with a 940-1524 serial cable.
As far as I can tell, this is supposed to work with smart signaling.
Here's my ups.conf:
2014 Dec 17
0
interrupt pipe disabled [APC SMT3000RMI2U]
Le Tue, 16 Dec 2014 20:38:50 -0500
Charles Lepple <clepple at gmail.com> ?crivait:
> On Dec 16, 2014, at 9:45 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
>
> > Bye the way I just realize that I can't retrieve the ups.load, among other
> > thing :-(
>
> To the best of my knowledge, Microlink is not supported by any third-party tools
2014 Dec 17
2
interrupt pipe disabled [APC SMT3000RMI2U]
On Dec 16, 2014, at 9:45 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
> Bye the way I just realize that I can't retrieve the ups.load, among other
> thing :-(
To the best of my knowledge, Microlink is not supported by any third-party tools (including NUT), but some variables are exposed via standard USB HID. Apparently, ups.load is not one of them.
Your UPS might
2014 Dec 05
2
Changing self test date
Le Thu, 4 Dec 2014 08:42:37 -0500
Charles Lepple <clepple at gmail.com> ?crivait:
> On Dec 4, 2014, at 5:30 AM, Frantz de Germain <frantz at info.univ-angers.fr>
> wrote:
>
> > Hello,
> >
> > does any one know how to change the date of the self tests on APC UPSes ?
> > I'd like to be able to choose the day and the hour so that it happens at
>
2014 Dec 19
1
Changing self test date
On Dec 18, 2014, at 9:16 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
> What is the difference between "test.battery.start.deep" and
> "test.battery.start.quick" command (upscmd) ?
The intent for the quick test is to only discharge the battery a little bit, whereas the deep test would discharge until the low battery threshold is reached (or the
2014 Dec 16
0
interrupt pipe disabled
Le Tue, 16 Dec 2014 15:36:29 +0100
Frantz de Germain <frantz at info.univ-angers.fr> ?crivait:
> Hello,
>
> I'm testing an APC SMT3000RMI2U connected to an USB port with Nut 2.7.2. I've
> got the message :
>
> "interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of this message)"
>
> I've been looking for
2014 Dec 18
0
Changing self test date
Le Fri, 5 Dec 2014 10:07:33 +0100
Frantz de Germain <frantz at info.univ-angers.fr> ?crivait:
> Le Thu, 4 Dec 2014 08:42:37 -0500
> Charles Lepple <clepple at gmail.com> ?crivait:
[...]
> > This forum post from 2013 suggests that an easy way is to change the UPS
> > setting to "test at power on", then use a script (with NUT, you would run
> >
2014 Dec 04
0
Changing self test date
On Dec 4, 2014, at 5:30 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
> Hello,
>
> does any one know how to change the date of the self tests on APC UPSes ? I'd
> like to be able to choose the day and the hour so that it happens at office
> hours, in case of any problem...
>
> I've tried to do this by launching a test at a convenient time, but
2012 Dec 04
2
Does NUT include support for older UPSD servers?
I have a network with two older systems protected by APC UPSs. Both
systems run OS/2 and will continue to do so. Both systems have APC
PowerChute Plus 4.2.3 installed and I can use that software to monitor
and control both systems.
I am also now running several linux systems, in fact I spend almost all
my time on the linux systems and these OS/2 systems are servers running
in the
2014 Dec 17
2
interrupt pipe disabled [APC SMT3000RMI2U]
On Dec 17, 2014, at 3:46 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
> This seems to me a little bit complicated :-( Instead, can I use the
> apcsmart driver with the provided 940-0625a c?ble (RJ45/DB9 connectors) ? Or
> do I need to acquire an AP9620 SmartSlot expansion card, as I've seen in the
> Hardware compatibility list page ?
It sounds like you might
2014 Dec 04
2
Changing self test date
Hello,
does any one know how to change the date of the self tests on APC UPSes ? I'd
like to be able to choose the day and the hour so that it happens at office
hours, in case of any problem...
I've tried to do this by launching a test at a convenient time, but the self
tests still occurs at the previous date and hour :-(
Regards.
--
Frantz de Germain
D?partement Informatique UFR
2014 Dec 16
4
interrupt pipe disabled
Hello,
I'm testing an APC SMT3000RMI2U connected to an USB port with Nut 2.7.2. I've
got the message :
"interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of this message)"
I've been looking for "pollonly" in the usbhid-ups man page, but it didn't help
me.
Could someone explain me what does this means exactly ? What are
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html
See the large commit message in the follow-up for the details and rationale.
I realize it's a bit larger diff - so if it's required I can split it into few
smaller ones.
Michal Soltys (1):
APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features
and fixes to the apcsmart driver, following the remarks in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html
Major changes from v1:
- handle battery.charge and battery.runtime checks at main.c level
- handle "immutable but writable" conflict gracefully at driver level
-
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work.
This is the next iteration of the patch adding some functionality to apcsmart
driver, and relying on 'ignorelb' recently added.
Follow up from previous thread:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html
Main differences is that V3 is split into many small patches, so the
2015 Jul 20
1
apcsmart: doesn't detect missing battery on Smart-UPS 2200 RM
Michal,
I ran across this Debian bug today:
https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=707223
It's a bit of a corner case, and it's for NUT 2.6.4 (apcsmart driver v3.04), but I was wondering if it was still applicable for the latest code?
"nut reports 100% battery charge after unplugging the battery on a Smart-UPS 2200 RM (SUA2200RMI2U) using apcsmart.
Powerchute correctly
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All,
I've got two APC SmartUPS's that behave differently with nut, I have a
SmartUPS1400 & a SmartUPS1250.
I'm fairly sure this isn't a nut problem but more likely a problem with
the age of the SmartUPS1250 and the apcsmart driver not being able to
identify it. Under the APC Powerchute software the same monitoring &
command parameters are available for both
2015 Jul 01
1
Need help
Hi,
I run os x yosemite and found out about NUT tonight. I messed around with fink and macports but get stuck very soon.
I dont know how to install anything that doesnt have a .dmg or .pkg installer.
Does anyone have a step by step (written in "for dummies" format on how to get this all to work? Just looking for a PowerChute alternative that actually lets me control and monitor my
2007 May 07
3
newhidups/APC: load always 0?
'lo,
UPS model: APC Back-UPS BR 800 (supplied by Dell)
My USB connection:
Bus 001 Device 002: ID 051d:0002 American Power Conversion Back-UPS Pro
500/1000/1500
# upsc desk@localhost|grep load
ups.load: 0.0
This UPS has 2 pc's and some minor other gear connected, yet the load
stays at 0.0 when checking with nut.
driver.version: 2.0.5
driver.version.data: APC/CyberPower HID 0.9
2014 Dec 16
0
interrupt pipe disabled
tisdagen den 16 december 2014 15.36.29 skrev Frantz de Germain:
> Hello,
Hi Frantz,
>
> I'm testing an APC SMT3000RMI2U connected to an USB port with Nut 2.7.2.
> I've got the message :
>
> "interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of
> this message)"
>
> I've been looking for "pollonly" in