2012 Oct 11
4
Eaton 3S550
Windows 7 Pro x64 Eaton 3S550 (brand new, battery mfg 8/15/2012) NUT 2.6.5-3 ups.status: OL CHRG CHRG was present even though it has been plugged in a few days turned on and battery.charge was 100%. Log includes me running upsc and removing power long enough to see that battery.charge will decrease. This UPS doesn't have controlled outlets despite what the upsc output says. ---
2012 Oct 01
1
Tripp-Lite INTERNET525U
Test machine: Windows 7 Pro x64, NUT 2.6.5-3 UPS model: Tripp-Lite Internet Office UPS (INTERNET525U) I needed a UPS and I had this old, but lightly used Tripp-Lite in storage. On the compatibility list I see a (?similar?) INTERNETOFFICE700 using the tripplite_usb driver. But the driver is not liking this particular model that I have. I'll be receiving a 3S550 soon, so I'm not
2013 Feb 07
1
Problem with NUT and an Eaton 5PX UPS, usbhid-ups won't start
Hello, I have trouble connecting to an Eaton 5PX UPS via the usbhid-ups driver. It is supposed to be fully working according to the compatibility list (support level 5). OS: A fresh Debian stable install. Then changed the apt source to unstable and did "aptitute update" and "aptitude install nut". Nothing else. I did that, because the "unstable" package is a more
2014 Nov 10
0
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
On Nov 9, 2014, at 9:35 AM, ??????? ?????????? <v.linch at icloud.com> wrote: > I've installed latest NUT under Windows XP, all works fine, but when I run "upsc ups" command I don't see the battery.voltage parameter, which I most need. Can you provide a few more details? The latest version of NUT (2.7.2 at the moment) has not been ported to Windows. Also, what does
2014 Nov 09
3
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
Hi all. I've installed latest NUT under Windows XP, all works fine, but when I run "upsc ups" command I don't see the battery.voltage parameter, which I most need. Please help, where am I wrong? --- Valeri Linchevski
2014 Jun 11
1
Setting the transfer threshold voltage on a TrippLite OMNI900LCD
At the company I work for, we are using many TrippLite OMNI900LCD UPSs and are having difficulty setting the lower transfer threshold voltage. On our other model, the Eaton MGE-3S550, this can be set using upsrw to set the input.transfer.lowsetting, but on the Omni900, this option is not available. In our testing, it defaults to ~95v but we want to set it to 84v. More info: - OS = OpenSuse 13.1 -
2014 Nov 10
2
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
My windows version is 2.6.5-3, latest on NUT site. "upsc ups" shows many ups parameters such as ups.load, battery.charge etc. but there is no battery.voltage, which I need (ups - is the name of my device in config). If I load driver usbhid-ups in debug mode (-DD), I see something like Ups.summary.bla-bla (sorry, don't remember exactly it's name) parameter with the value, which
2012 Jul 21
1
Windows NUT shutdown UPS?
I was wondering what you guys do about UPS shutdown on Windows systems? Apcupsd has the same issue, so I'm assuming it is the same with NUT. Windows just makes it hard/impossible to do. Do you find draining the batteries down so much cause issues for longevity? Regarding my Eaton 5110, I found that automatic driver setup works just fine on Windows XP but not at all on Windows 7 x64 (I
2018 Oct 09
0
NUT driver usbhid-ups for EATON 5E650iUSB does not work on CENTOS 6.1
OS name and version, *CentOS release 6.10 (Final) Linux 2.6.32-754.3.5.el6.centos.plus.x86_64 #1 SMP Wed Aug 15 02:28:38 UTC 2018 x86_64 x86_64 x86_64 GNU/Linux* exact NUT version Name : nut Arch : x86_64 Version : 2.6.5 Release : 2.el6 Size : 4.2 M Repo : installed >From repo : epel Summary : Network UPS Tools URL :
2014 Nov 10
0
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
On Nov 10, 2014, at 9:10 AM, ??????? ?????????? <v.linch at icloud.com> wrote: > My windows version is 2.6.5-3, latest on NUT site. > "upsc ups" shows many ups parameters such as ups.load, battery.charge etc. but there is no battery.voltage, which I need (ups - is the name of my device in config). > If I load driver usbhid-ups in debug mode (-DD), I see something like
2013 Jul 18
1
UPS Liebert GXT-3
Kris Jordan <nut.kj <at> sagebrushnetworks.com> writes: > > Marcelo Roccasalva wrote, On 3/1/2013 12:10 PM: > > On Thu, Feb 28, 2013 at 6:17 PM, Marcelo Roccasalva <roccas <at> gmail.com> wrote: > >> On Tue, Feb 26, 2013 at 10:56 PM, Charles Lepple <clepple <at> gmail.com> wrote: > >>> On Feb 21, 2013, at 6:21 PM, Marcelo
2015 Jul 27
0
[HCL] Eaton 5E1100i supported by usbhid-ups
Device manufacturer and name: *Eaton 5E 1100i USB* *upsc eaton5e* Init SSL without certificate database eaton5e root at eger:/home/siposg# upsc eaton5e Init SSL without certificate database battery.charge: 100 battery.runtime: 3160 battery.type: PbAc device.mfr: EATON device.model: 5E 1100i device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton Device Name: 5S1500LCD ---------------------------------------------------------- upsc output: battery.charge: 100 battery.charge.low: 20 battery.runtime: 3515 battery.type: PbAc device.mfr: EATON device.model: Ellipse PRO 1500 device.serial: 0000000000 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton Device Name: 5S1500LCD ---------------------------------------------------------- upsc output: battery.charge: 100 battery.charge.low: 20 battery.runtime: 3515 battery.type: PbAc device.mfr: EATON device.model: Ellipse PRO 1500 device.serial: 0000000000 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2
2018 Jul 03
2
No run cmd /usbhid-ups -k !
Hi all. UPS is Eaton 5SC 500i. I tested three solutions: 1. swap "usbhid-ups -a qnapups" with "usbhid-ups -a qnapups -k" Result: server shutdown, but ups does not shut off! 2. run prog with params "upsmon -c fsd" Result: server shutdown, but ups does not shut off! 3. run prog "upscmd -u name -p passwd qnapups shutdown.return" and next
2020 Jul 30
0
Eaton 5E 2000i - incorrect values reported by usbhid-ups
Hi, I've recently bought the UPS in subject to support a small load (around 60-80W). I've installed nut and did the basic configuration and confirmed basic communication. At that stage I did not configure upsmon, but simply was monitoring the values. I carried out a test to see how long the setup would last - according to the values reported via upsc - it should have been around 45mins.
2014 Nov 10
3
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20141111/7dd98eaa/attachment-0001.html> -------------- next part -------------- A non-text attachment was scrubbed... Name: usbhid.zip Type: application/zip Size: 5991 bytes Desc: not available URL:
2014 Nov 11
0
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
On Nov 10, 2014, at 6:44 PM, Valeri Linchevski <lincher at ya.ru> wrote: > Parameter, "blabla" :-) really is Ups.PowerSummary.Voltage, debug output is in attach. > Apparently some models are missing from the table that is consulted for "mge_type": https://github.com/networkupstools/nut/blob/master/drivers/mge-hid.c#L201 Arnaud or Emilien, Is there any way we
2014 Nov 11
2
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20141111/42cd1a34/attachment.html>
2014 Nov 11
0
Eaton-9130 (usbhid-ups) no battery.voltage parameter!
On Nov 10, 2014, at 11:00 PM, Valeri Linchevski <lincher at ya.ru> wrote: > So, how can I get this value? You could comment out the switch statements in drivers/mge-hid.c, functions mge_battery_voltage_nominal_fun() and mge_battery_voltage_fun(), and recompile. I logged an issue for fixing this the right way: https://github.com/networkupstools/nut/issues/170 -- Charles Lepple clepple