Displaying 20 results from an estimated 2000 matches similar to: "nut-2.6.5: ups.timer.start problem with EATON Protection Station 650"
2020 Jan 08
0
Hardware compatability report: Eaton Ellipse ECO 1600
Here is a Compatibility Report for the Eaton Ellipse ECO 1600 UPS. Roger
battery.charge: 100
battery.charge.low: 20
battery.runtime: 1575
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse ECO 1600
device.serial: 000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.lowbatt: 37
driver.parameter.offdelay: 30
driver.parameter.ondelay: 40
driver.parameter.pollfreq: 30
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2017 Apr 07
0
[Eaton 5S 1500] overvoltage shut down?
Hello Charles,
I've attached a dump below. There were no long entries on any of the hosts,
neither the one running standalone, nor the master/slave combo, which is
not too surprising, it was really fast: I saw the light flickering in the
room, almost like flash, and all those 3 systems went down. I first heard
the "click" of the ports being disabled, heard the systems shut down, and
2014 Dec 17
2
EATON 9SX not display battery.charge
OS version: FreeBSD 8.4-RELEASE-p19
NUT version: nut-2.7.2_6
NUT installation method: from freebsd pkg system
Device info: EATON 9SX 5000i, manufacturing date: 05.09.2014
ups.firmware: 9SX5Ki
When i try to see battery charge, in output it have not such variable,
and i can't control my server and other clients connected to them. Any
options cannot power of server. How to see current battery
2014 May 05
1
communication problems with eaton 9130 over usb
Hi!
I am not really experienced with UPS devices or UPS control software
like NUT but i am enthusiastic and trying to use Eaton-9130 (it has one
extra EBM too) as rationally as possible with NUT. I believe in general
things are under control and behave, although i have some glitches and i
would like to ask for help.
I am using Debian v. 7 amd64 and from its packages nut-server and
nut-client, v.
2010 Feb 22
2
PowerOff on Debian, and driver issues
Hi!
After some problems doing the automatic shutdown of the UPS on Debian, I
have found this Debian bug:
http://bugs.debian.org/cgi-bin/bugreport.cgi?bug=293401
Now I fixed it calling always ups-monitor from the halt script despite
being halt'ed' or powered off (and relying on the POWERDOWNFLAG be set).
Which is the correct aproach or best solution to workarround this bug?
And now my
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
Hi,
I've been using NUT for many years to look after the UPS on my home
servers. Originally I was using a Compaq R3000 but that was replaced
with an MGE Pulsar Evolution 3000 about a couple of years ago because
the Compaq one was just too noisy!
I'm just setting up a replacement server and would like to connect it
using a serial cable as I've found that the USB connection
2007 Aug 11
1
[MGE EVOLUTION 850 VA/ ups 2.0.4] Output.voltage is at 0.0
Hello !
I've just a problem with upsd/upsmon 2.0.4, please have a look at the upsc command:
--------------------
battery.charge: 59
battery.charge.low: 5
battery.runtime: 1312
battery.voltage: 24.0
driver.name: newhidups
driver.parameter.port: auto
driver.version: 2.0.4
driver.version.data: MGE HID 0.9
driver.version.internal: 0.28
input.frequency: 0.0
input.transfer.boost.low: 184.0
2007 Jan 09
1
Differences between newhidups (MGE tables) in 2.0.4 and svn trunk
I was looking at how other drivers deal with outlet collections, and I
noticed some differences between newhidups in 2.0.4 (from Debian's
2.0.4-2.3) and the SVN trunk (rev 723) on an Evolution. Full diff is
below, but here are the highlights:
* MGE HID 0.9 vs 1.0
* outlet.#.switch seems to have moved to the commands outlet.#.load.{on,off}
Then I found this in the ChangeLog:
* fix
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
I am running NUT 2.2.0 compiled from the FreeBSD ports tree.
[inchoate 14:50] ~ >upsc ups1 at localhost
battery.charge: 59
battery.charge.low: 20
battery.charge.restart: 0
battery.runtime: 6350
battery.type: PbAc
battery.voltage: 43.0
driver.name: usbhid-ups
driver.parameter.offdelay: 120
driver.parameter.ondelay: 13
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version:
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote:
> Dear All,
>
> Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility?
>
> 850 or 1000 VA
>
> I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it.
>
> Thank you,
> Bart
Can you tell
2010 Oct 06
1
Model list missing my UPS, here is info for inclusion on the list
Hello Niels,
thanks a lot for this compatibility submission. This is part of the
remaining things at Eaton.
I've added an entry to the new Hardware Compatibility List:
http://new.networkupstools.org/stable-hcl.html
BTW, have you tested a shutdown with this unit?
Otherwise, you should!
thanks again,
Arnaud Quette
Le samedi 02 octobre 2010 ? 12:42 +0200, Niels Kristian Jensen a
?crit :
2014 May 26
2
Resetting replace battery status on Pulsar 1500
Hi,
I have a FreeBSD 9.2 system with NUT 2.6.5 (installed via the ports tree) with an MGE Pulsar 1500 connected. A while ago it complained it needed the battery replaced and it was finally replaced last week, however I can't find out how to reset the flag in NUT.
I've looked in upsc, upsrw and upscmd but none seem to have a suitable option.
The UPS is connected via RS232 and upsc output
2006 May 11
0
MGE Pulsar Extreme communication problems
Hi,
I am trying to talk to an MGE Pulsar Extreme UPS over RS232 with the
mge-shut driver but I'm having some problems.
It appears to init OK but I can't, say, turn the outlets off, eg..
harrow:~>upsc mge@localhost
battery.charge: 78
battery.charge.low: 20
battery.runtime: 05760
driver.name: mge-shut
driver.parameter.port: /dev/cuad1
driver.version: 2.0.3
driver.version.internal: 0.65
2007 Feb 01
2
NUT-2.0.3 - problems on setting values
Hello,
we have a MGE Pulsar Evolution 800 connected to a Fedora Core5 Server
using a serial cable.
Installed and configured properly are RPM versions of
nut-2.0.3-0.1.fc5
nut-client-2.0.3-0.1.fc5
nut-cgi-2.0.3-0.1.fc5
which all work (mostly) fine.
The server is connected to outlet.0 and properly shuts down when it's
loosing power after around 20 minutes. It also boots up whenever the ups
2014 Jun 05
0
Question about voltage threshold setting in NUT
Hey Charles,
Latest update. Looks like in ups.conf I setup default.input.transfer.low =
84. After I took that line out, restart upsdrvctl, upsmon, and upsd, the
command of
sudo upsrw -s input.transfer.low=70 -u * -p * ups
return OK. Still need to verify if it works by using voltage regulator and
will keep you updated.
Thank you for your help
Regards
Shen
On Thu, Jun 5, 2014 at 8:54 AM,
2013 Dec 25
2
Delayed UPS start up after shutdown?
On 12/25/2013 12:16 AM, Kris Jordan wrote:
> Angel Tsankov wrote, On 12/24/2013 1:22 AM:
[...]
>> I can see that my UPS (MGE Protection Center 675) has a parameter
>> ups.timer.start (currently holding the strange value of -10). Any idea
>> if this could help and how this parameter can be changed?
>
> in upsrw?
In upsc only. Here's the complete output:
2020 Sep 30
2
reset "replace battery" flag
On Fri, Sep 25, 2020 at 11:47:42PM +0300, Manuel Wolfshant wrote:
> On 9/25/20 1:36 PM, Lionel Élie Mamane wrote:
>> On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote:
>>> On 9/21/20 9:47 PM, Lionel Élie Mamane wrote:
>>> We have a HP R/T 3000 G4 UPS; according to the data returned by
>>> the usbhid-ups driver, it seems to be a "badge
2007 Mar 12
3
upsmon keeps broadcasting on battery / on power (driver is newhidups)
Hi,
I try to install the newhidups driver for a MGE Pulsar M2200 connected to a USB
port under Linux Red Hat 4 Upd 4.
I have compiled and installed the usb driver (make usb && make install-usb). I
followed the instructions in /nut-2.0.5/scripts/hotplug-ng/README abour the
/etc/udev/rules.d/025_nut-usbups.rules.
The ups is recognized by the kernel:
Mar 12 14:52:03 serveur1 kernel: usb