similar to: Voltage transfer points.

Displaying 20 results from an estimated 10000 matches similar to: "Voltage transfer points."

2006 Aug 03
1
Re: [Nemo-devel] nuts status page
Adam: Thanks for putting up this page. But something is wrong. In particular, our Powerware 9135 is a three phase UPS system with THREE 480 volt outputs. So the displayed voltage is not correct -- in fact there should really be THREE voltages displayed, all around 480v. Nut developers: I am copying the NUT mailing list to see if anyone can suggest how to fix this. NUT developers, see the
2009 Jun 20
1
upsmon says ONBATT when status: TRIM
Hi, I've been getting emails from upsmon saying: Subject: UPS PW5125 at localhost notification: ONBATT UPS PW5125 at localhost on battery But then the machines on the UPS stay on for hours; we haven't got that kind of runtime, more like 10-20 minutes. After a few occurrences, it now happened at a time where I could log in to see in real time what is happening and: $ upsc PW5125 |
2013 Jul 02
2
bcmxcp: Patch for adding ups.load and battery.voltage.low
Hi I have the following UPS : ups.mfr: Eaton ups.model: POWERWARE UPS 500i ups.power.nominal: 500 It is using the bcmxcp_usb driver. I started the driver with debug options, and noticed the following for the meter map : 0.475625 0027 0000 51 output.frequency 0.475634 0028 0004 51 input.frequency 0.475641 0033 0008 51 battery.voltage
2012 Oct 26
3
Eaton , Powerare 9120 6kva
Are there driver to this device it works? I trie with 9130 and 9140 driver but didn't work. Thanks Ignacio Fridemberg -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20121025/af016ac1/attachment.html>
2009 Dec 27
4
XPCC XVRT-1000 driver
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Has anyone used nut with a XPCC UPS, in particular one of the XVRT units? Their supplied monitoring tool "works", but I'd really prefer to use nut if possible. I've systematically gone through each of the drivers in /lib/nut and none seem to talk with the unit properly. I'll be talking with a XPCC support person tomorrow, though
2015 Nov 23
2
[PATCH 0/2] Fix some voltage issues found on Kepler cards
With these both patches, most of the kepler cards should be able to reclock their core clock without issues. These patches should be tested carefully among nouveau devs, so that these don't break reclocking on other cards (especially Teslas). Particularly the second one might break reclocking here and there. Karol Herbst (2): bios/volt: handle voltage table version 0x50 with 0ed header
2006 Aug 17
1
powercom upstype identify problem
Mr Claesson, with my current configuration, the ups.status when the UPS is disconnected from the mains is "OB". There is no more "OB BOOST". Now my upsd.users is: [root] password = password allowfrom = localhost upsmon master actions = SET instcmds = ALL and upsmon.conf is: RUN_AS_USER root MONITOR Inform@localhost 1 root password master MINSUPPLIES 1 SHUTDOWNCMD
2014 Nov 28
2
[PATCH 1/2] volt: allow non-bios voltage scaling
Signed-off-by: Vince Hsu <vinceh at nvidia.com> --- nvkm/subdev/volt/base.c | 67 ++++++++++++++++++++++++++++--------------------- 1 file changed, 38 insertions(+), 29 deletions(-) diff --git a/nvkm/subdev/volt/base.c b/nvkm/subdev/volt/base.c index 32794a999106..26ccd8df193f 100644 --- a/nvkm/subdev/volt/base.c +++ b/nvkm/subdev/volt/base.c @@ -101,6 +101,41 @@ nouveau_volt_set_id(struct
2007 Mar 28
4
snmp ups Status: Not supported
Hi I set up my ups with driver snmp-ups, and it get recognized as a AEC T2003. In the nut-cgi upstats page input/output/load are displayed corectly, but the Status field is marked as "Not supported". Is "Status" important to initiate shutdown in case of low battery ? Will my server shut down correctly ? thanks Massimo I include "upsc snmp@localhost" output:
2005 Sep 23
11
trying to use powerware 3110 USB with NUT
Ok, I installed the ups, and installed nut, and /proc/bus/usb/devices says this T: Bus=03 Lev=01 Prnt=01 Port=01 Cnt=01 Dev#= 2 Spd=1.5 MxCh= 0 D: Ver= 1.10 Cls=00(>ifc ) Sub=00 Prot=00 MxPS= 8 #Cfgs= 1 P: Vendor=06da ProdID=0002 Rev= 0.01 S: Manufacturer=POWERWARE S: Product=Powerware UPS C:* #Ifs= 1 Cfg#= 1 Atr=80 MxPwr= 20mA I: If#= 0 Alt= 0 #EPs= 1 Cls=ff(vend.) Sub=00 Prot=00
2016 Mar 28
1
[PATCH v2 06/22] volt: parse the both max voltage entries
On 21/03/16 18:16, Karol Herbst wrote: > these entries specify a maximum voltage nvidia never exceeds, we shouldn't do > that, too. > > Signed-off-by: Karol Herbst <nouveau at karolherbst.de> > --- > drm/nouveau/include/nvkm/subdev/bios/vmap.h | 2 ++ > drm/nouveau/include/nvkm/subdev/volt.h | 2 ++ > drm/nouveau/nvkm/subdev/bios/vmap.c | 5
2016 Apr 20
2
[PATCH 0/2] add min/max voltage to hwmon
The first patch is also part of my reclocking series Karol Herbst (2): volt: save the voltage range we are able to set hwmon: add in_min and in_max drm/nouveau/include/nvkm/subdev/volt.h | 3 +++ drm/nouveau/nouveau_hwmon.c | 36 ++++++++++++++++++++++++++++++++++ drm/nouveau/nvkm/subdev/volt/base.c | 14 ++++++++++++- 3 files changed, 52 insertions(+), 1 deletion(-) --
2016 Mar 16
2
[PATCH 0/2] Fix some VID parsing in the voltage table version 0x50
On a very few GPUs with the voltage table version 0x50 we have to read out the VIDs out of the entries of the table, where all the other gpus are either PWM based or get a base and a step voltage out of the table header. Currently nouveau tried to autodetect this and actually doesn't parse the entries. This Series adds two things: 1. It parses the entries 2. It decides upon a field in the
2019 Aug 02
1
[PATCH] volt: Fix for some cards having 0 maximum voltage
Some, mostly Fermi, vbioses appear to have zero max voltage. That causes Nouveau to not parse voltage entries, thus users not being able to set higher clocks. When changing this value Nvidia driver still appeared to ignore it, and I wasn't able to find out why, thus the code is ignoring the value if it is zero. CC: Maarten Lankhorst <maarten.lankhorst at linux.intel.com> Signed-off-by:
2017 Mar 03
2
MGE ESV+ and Power Trim
On Mar 3, 2017, at 8:21 AM, Charles Lepple <clepple at gmail.com> wrote: > > On Mar 2, 2017, at 3:38 PM, David Baker <david at baker.im> wrote: >> >> I?ve read the documentation, and it would appear that this can be set by the U-Talk protocol (page 34 of http://networkupstools.org/protocols/mge/9261zwfa.pdf) but I can?t seem to figure out how to send the device the
2016 Mar 16
1
[PATCH v2 2/2] volt: properly detect entry based voltage tables
there is a field in the voltage table which tells us if the VIDs are taken from the entries or calculated through the header v2: don't break older versions of the table Signed-off-by: Karol Herbst <nouveau at karolherbst.de> --- drm/nouveau/include/nvkm/subdev/bios/volt.h | 5 +-- drm/nouveau/nvkm/subdev/bios/volt.c | 47 ++++++++++++++++-------------
2006 Apr 21
1
RE: [Nut-upsuser] SOS : Help needed for UPS CentralionBlazer2000VAUSB
Ok Guillaume, It is Megatec protocol. It sends Q1<cr> and answers with (227.2 227.2 227.2 038 50.1 13.5 25.0 00001001<cr> And if you check http://eu1.networkupstools.org/protocols/megatec.html it matches. And now, ho has time to code ? Kjell fre 2006-04-21 klockan 17:18 +0200 skrev Guillaume JAOUEN: > Hello, > > As I wish to help you the most I can in order to get a
2016 Mar 17
22
[PATCH 00/19] Volting/Clocking improvements for Fermi and newer
This series fixes most of the issues regarding volting on GPUs with any form of GPU Boost inside their vbios, which is mainly Kepler and newer, but we find some boosting related tables in Fermi vbios' already In the end reclocking should work on most Kepler cards without any issues Karol Herbst (19): bios/volt: handle voltage table version 0x50 with 0ed header volt: properly detect entry
2016 Feb 29
9
[PATCH 0/9] Groundwork for clocking fixes
This series contains a lot of groundwork to finally fix reclocking issues on Kepler+ gpus. There shouldn't be any functional changes with the first patch being the only exception (fixes some voltage table parsing issues with of few kepler gpus) The most interessting thing is the tool in the last patch, which can be ran alongside the nvidia driver to test nouveaus volting code and print the
2013 Jul 02
0
bcmxcp: Patch for adding ups.load and battery.voltage.low
tisdagen den 2 juli 2013 20.24.47 skrev Alf H?gemark: > Hi > Hi Alf, > I have the following UPS : > ups.mfr: Eaton > ups.model: POWERWARE UPS 500i > ups.power.nominal: 500 > > It is using the bcmxcp_usb driver. > > I started the driver with debug options, and noticed the following for > the meter map : > > 0.475625 0027 0000 51