similar to: (no subject)

Displaying 20 results from an estimated 4000 matches similar to: "(no subject)"

2010 Dec 02
1
Powercom SXL-1000A-LCD
Hi All! I have a traoble whith my ups, - megatec driver can not calculating % of charging and voltage on battery: # uname -a FreeBSD backup.*.*.* 8.1-RELEASE FreeBSD 8.1-RELEASE #0: Wed Sep 22 12:25:01 EEST 2010 ups.conf [Powercom] driver = megatec port = /dev/cuau0 #battvolts=12:24 desc = "powercom sxl-1000A" # ./nut start Network UPS Tools - UPS driver controller 2.4.1
2010 Dec 02
1
(no subject)
I am have a nice result whith blazer_ser driver! respect! # ./nut start Network UPS Tools - UPS driver controller 2.4.1 Network UPS Tools - Megatec/Q1 protocol serial driver 1.51 (2.4.1) Supported UPS detected with megatec protocol Vendor information read in 1 tries Battery runtime will not be calculated (runtimecal not set) <================= !!! Starting nut. Network UPS Tools upsd 2.4.1
2010 Dec 17
3
online zinto usv
Hello, today I'm fighting with a Online Zinto 1000 (lsusb.txt) produced by Phoenixtec/Eaton ;-) http://www.eaton.com/EatonCom/OurCompany/NewsandEvents/NewsList/CT_141334 I have tested different drivers without success (please see attachments usbhid-ups.txt, bcmxcp_usb.txt, blazer_usb.txt) The help got unfortunately time outs (explore.txt)
2009 Nov 16
1
[Fwd: Re: Can anyone give me some ideas?]
Arjen de Korte ha scritto: > Citeren Nick Warr <nick at mobilia.it>: > >>> How is the driver failing? >> It says there's no Megatec protocol UPS on that port more or less. > > Could you run the driver in debug mode and post the (gzip'ed) logs as > an attachment? > > /path/to/megatec -DDD -a upsname > > The upsname should be the name as
2009 Mar 10
2
NUT and Ablerex MARS 3000RT
Hello, I own some Ablerex MARS 3000 (MS3000RT) UPS. Following the thread here : http://osdir.com/ml/monitoring.nut.user/2006-04/msg00091.html I would have the following issues : 1. The battery charge displayed seems wrong : It always shows 100.0 - even when the battery is disconnected for replacement. 2. Battery voltage 2.29 is also static ...and wrong. The initial assumption of being the voltage
2010 Mar 06
2
Adding support for NUMERIC UPS
Hi, I have been blessed with the "Numeric 2000 Plus" UPS, suspected to be of 2KVA rating. This UPS does not figure in the list of UPS recognised by NUT. However I get lucky with megatec driver. Here is the log... ----------------------------------------------------------------------------------------------------- Network UPS Tools - Megatec protocol driver 1.5 (2.0.5) Carlos Rodrigues
2009 Oct 24
1
Shutdown N-POWER MV-1000 LT UPS is not working
Hello! I use online UPS MV-1000 LT http://www.230v.ru/catalogue/?id=production/ups-sm/master-vision for the power of my Linux server SLES 10 SP1. I downloaded, compiled and configured diver nut 2.4.1 from this link http://www.networkupstools.org/source/2.4/nut-2.4.1.tar.gz Here are my configuration files: --- srv:/usr/local/ups # cat etc/ups.conf [npower] driver = megatec port = /dev/ttyS0
2010 Jul 09
2
SMS PowerVision PV2200 BIFX
Hello, I have two SMS PowerVision PV2200 BIFX, that came with a serial port, I used a serial - usb conversor to conect it to my pc it recognized as: lsusb -s 001:005 -vvv Bus 001 Device 005: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at
2009 Dec 28
4
Megatec driver floods logs #2 & mail notifications
Hi there! I'm a n00b NUT user trying to get it running on RHEL5 and actually do something useful for me. Few questions: 1) I want it to notify me by email on power loss and power back events. I can't find any sample scripts for this purpose... Where shall I look for them? 2) So far, I've backported the package from Fedora and got my Ablerex running (previously used with Upsilon /
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Hello First things first, thanks for great work with NUT. For years I used Informer compact 3kVA UPS http://www.informups.com/informer_compact.html with nut/megatec serial driver, but it stopped working when I switched to blazer_ser with 2.6.0 upgrade. I'm using 2.6.0 on gentoo. Blazer_ser seems to connect with UPS, but upsmon reports driver not connected. uname -a Linux localhost
2010 Feb 08
1
megatec and blazer drivers for (brand)Tuncmatik (series)Newtech Pro 1KVA
Hi, I would like to report that Tuncmatik Newtech Pro 1 KVA (http://www.tuncmatik.com/en-US/productDetail.asp?RecID=290) works with nut(2.4.1) blazer_usb, blazer_ser and megatec drivers. The UPS came with an usb cable and a java based software for both linux and windows, named ViewPower (http://www-power-software-download.com). This UPS has double interface a USB interface and a serial
2010 Feb 09
2
Online Xanto S1000 Driver
Good morning, i have an Xanto S1000 USV the Manufactor is ONLINE USV-Systeme AG. I tried all the buildin drivers, also the driver for the driver for the Generic UPS, nothing worked for this UPS so now my question has anyone else this UPS and functional driver? Thanks and Greets Dennis
2010 Oct 13
2
ups nut-2.4.x bug. driver megatec forceshutdown may dont work.
2010/10/13 Vitaly Lavrov > I found bug in nut/drivers/megatec.c - force shutdown may dont work. > See patch. > could you please give a try to blazer, since it is set to replace megatec with 2.6.0. Arjen will quite probably comment on your patch usefulness within the blazer scope. thanks for your contrib. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton -
2012 Sep 06
2
Communications with UPS lost: No status from UPS
Hello, i've a problem, this is my configuration: - Atlantis Land UPS with serial port - a generic RS232 to USB cable adapter (QinHeng Electronics HL-340 USB-Serial adapter for linux). The problem is in the syslog file where i find: [...] Aug 19 09:07:25 ProLiant megatec[1126]: Communications with UPS lost: No status from UPS. Aug 19 09:07:26 ProLiant megatec[1126]: Communications with UPS
2009 Aug 09
1
New NUT HCL entry / (brand)Inform (series)Informer Compact
Hi Mutlu, 2009/8/7 Mutlu T. <cmtunc at gmail.com> > Redirecting to debian.org domain due to being rejected as spam by free.fr > > > ------- Forwarded message ------- > From: "Mutlu T." <cmtunc at gmail.com> > To: arnaud.quette at free.fr > Cc: > Subject: New NUT HCL entry / (brand)Inform (series)Informer Compact > Date: Fri, 07 Aug 2009 15:31:04
2020 Jul 07
2
New UPS to the DB
Hi, I have an OEM of KStar UDC9101S which is Megatec protocol rs232 capable unit. So I use blazer_ser protocol=megatec /dev/ttyUSB0 with no issue to get NUT running. Please direct me what command should I issue to collect the data in order to include the UPS to device database? P.S. tryed /lib/nut/blazer_ser -DD... but no difference from a regular output has being added by the driver.
2019 Aug 06
4
Monitor UPS Brand SMS
Hi Users NUT, I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a raspberry-pi. In compatibility list, is listed to use the blazer_ser driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow the comands e confs. root at rasp:/home/pi# lsusb *Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port* Bus 001 Device 003: ID 0424:ec00 Standard
2018 Aug 19
2
Protocol for an Arduino based UPS
Hi, I'm building a DIY UPS for a Raspberry Pi using a 12V SLA battery, charger, and an off the shelf 5V regulator. To monitor the battery level I'd like to use an Arduino or similar type device. Since the Arduino can have a serial over USB connection with the Pi I'd like to implement a protocol that can be used with NUT. Does anyone know if something like this has already been done?
2015 Nov 16
2
Contact-closure UPS
Hi Charles, >----- Original Message ----- >From: "Charles Lepple" <clepple at gmail.com> >To: "R?bert SZAKSZ" <robert at szaksz.eu> >Cc: nut-upsuser at lists.alioth.debian.org >Sent: Monday, November 16, 2015 3:20:17 PM >Subject: Re: [Nut-upsuser] Contact-closure UPS > >[please use reply-all when responding - the list does not modify the
2014 Jun 02
2
blazer_ser battery.high / battery.low
Hi, thanks for the reply. On 2014-05-29 05:21, Charles Lepple wrote: >> Now my questions: >> 1. should the blazer_ser's high voltage be the voltage during charging >> or right after I've unplugged it from the mains? > sounds like during charging (or more accurately, during float charging at the end of the cycle): > >