similar to: Success and USB IDs for TrippLite SmartOnline SU1000RTXL2ua

Displaying 20 results from an estimated 800 matches similar to: "Success and USB IDs for TrippLite SmartOnline SU1000RTXL2ua"

2010 May 10
3
Support for Tripp Lite SmartOnline SU1000XLA?
Hi, I'm running the latest stable nut (2.4.3). It doesn't appear to provide support for the Tripp Lite SmartOnline SU1000XLA. [sups] driver = usbhid-ups port = auto vendorid = 09ae productid = 4004 4337# upsdrvctl start Network UPS Tools - UPS driver controller 2.4.3 Network UPS Tools - Generic HID driver 0.34 (2.4.3) USB communication driver 0.31 Using subdriver:
2016 Oct 20
2
TrippLite SU3000XLCD
I'm having trouble with a TrippLite SU3000XLCD. I'm using a Raspberry Pi running Raspbian (wheezy) with NUT 2.6.4. I can monitor my older TrippLite UPSs, mostly SU1000RT2Us, with this Pi and a USB to serial adapter. My first thought with the SU3000XLCD was to use the USB port instead of the serial port as that's the "modern" thing to do. When I plugged the USB cable in
2020 Mar 26
0
thoughts on tripp lite Smart Online UPSs?
On Mar 25, 2020, at 6:09 PM, Lee Damon <nomad at ee.washington.edu> wrote: > > I have no experience with Tripp Lite UPSs and the reviews I've found online are scant and fairly mixed so I thought I'd ask here... It's always hard to get a good read on whether a particular UPS brand is problematic, or if there is more noise on the lists because people are trying to make
2010 Mar 09
1
Tripp-Lite SU2200XLA problem
Hi, I kludged support for the TrippLite SU2200XLA into nut-2.4.3 as follows: --- ./drivers/tripplite-hid.c.0 2010-03-03 15:53:20.000000000 -0500 +++ ./drivers/tripplite-hid.c 2010-03-03 15:53:40.000000000 -0500 @@ -81,6 +81,8 @@ { USB_DEVICE(TRIPPLITE_VENDORID, 0x4002), battery_scale_1dot0 }, /* e.g. TrippLite SmartOnline SU1500RTXL2ua */ {
2006 May 18
1
Tripplite SU2200XL
Can anyone help getting a Tripplite SU2200XL to work with nut 2.0.3 using the supplied serial cable? Starting the ups service yields: Starting tripplitesu: Network UPS Tools - Tripp Lite SmartOnline driver 0.02 (2.0.3) Unable to detect Tripp Lite SmartOnline UPS on port /dev/ttyS0 I also have Tripplite's PowerAlert 12 software installed and when run it finds the UPS without a problem. So
2020 Mar 25
5
thoughts on tripp lite Smart Online UPSs?
We're looking at replacing some old APC SmartUPS 5000s with something that has USB so NUT can more easily talk with it (and yes, I've tried USB-RS232 adapters and every one I tried started kicking out errors within a few hours). One of the bids we have is for a "Tripp Lite UPS Smart Online 5000VA 4500W Rackmount 5kVA 200V/240V" as the potential replacement unit. I have no
2010 Mar 26
5
Tripp Lite SmartOnline 3U
I have the following UPS that I'm trying to get to work with NUT: SU3000RTXL3U I have it connected via USB. My ups.conf looks like: [test] driver = usbhid-ups vendorid = 09ae port = auto When I run upsdrvctl -DD start, I get: Network UPS Tools - UPS driver controller 2.4.1 Starting UPS: test exec: /lib/nut/usbhid-ups -a test Network UPS Tools - Generic HID driver 0.34 (2.4.1)
2020 Mar 25
2
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
Re: "Does it work well with NUT?" Assuming it is the SU5000RT4UHV, the similar units I've tried seemed to work fine. For reference, the SU5000RT4UHV should be a 4004 USB protocol. ________________________________ From: David Zomaya Sent: Wednesday, March 25, 2020 5:21 PM To: Lee Damon; nut-upsuser Mailing List Subject: Re: [EXTERNAL] [Nut-upsuser] thoughts on tripp lite Smart
2014 Feb 07
3
Tripplite UPS (SU10KRT3/1X) through snmp-ups (nut 2.6.5)
Hi, Nut-upsusers, I am having problem configuring NUT to work with Tripplite UPS through SNMP. There is a Tripplite SmartOnline SU10KRT3/1X and attempts to monitor it using NUT though SNMP are failing... OS: Enterprise Linux 6, Nut version: 2.6.5. ups.conf is configured: [trippliteups] driver = snmp-ups port = 10.200.254.39 desc = "ProductionServer"
2005 Dec 19
1
tripplitesu driver fix
The 2.0.2+ tripplitesu drivers do not recognize SmartOnLine SU2200XL and possibly other SmartOnLine UPSes. Here is a one-line fix. Lee --- ../nut-2.0.2/drivers/tripplitesu.c Thu Jan 27 08:33:21 2005 +++ drivers/tripplitesu.c Sat Oct 1 13:38:51 2005 @@ -227,7 +227,7 @@ buffer[4] = '\0'; if (!strcmp(buffer, "~00D")) { - if (ser_get_buf_len(upsfd, buffer, 4, 3, 0) <=
2007 Jan 21
1
TrippLite USB UPS
Good afternoon, I am trying to communicate with a new Tripp-Lite UPS via usb and having little luck. After more than a week on this I've decided to ask for help. I am very inexperienced at posting information to message boards, so hopefully I'm doing this right. I assume this is the correct place to post this message. I will start with the equipment I have. I am using Debian Sarge
2009 Mar 06
2
Question about Tripplite SU10KRT3U
Hello list! I can't seem to get this running via RS232 monitoring; I've been told that NUT won't support serial connections, and find this hard to verify. Does anyone else have this running on the SU10KRT3U via RS232? If so, what driver did you use? I'm getting no satisfaction from the "tripplite" driver; upon upsdrvctl start, I get "Failed to find UPS - giving
2008 May 08
0
Tripplite SU1500RTXL2Ua and nut versions, battery line state fluctuates
I am trying to get a TrippLite SU1500RTXL2Ua working with nut on Mandriva 2007.1, is there a particular version of nut needed to get this to work? At first I tried nut 2.0.5 (which came with 2007.1) but it wouldn't work, and then research showed it was an older version of nut. So nut-2.2.1-2 src rpm was pulled from Mandriva 2008.1, the binary rpm built, and nut and nut-server installed from
2007 Mar 08
1
Tripp-Lite SU6000RT4U - not supported?
Greetings, I have a Tripp-Lite SU6000RT4U unit connected via USB and RS-232. # tripplitesu -DD -u root -a tl6000 Unable to detect Tripp Lite SmartOnline UPS on port /dev/ttyS0 # tripplite -DD -u root -a tl6000 Failed to find UPS - giving up... # newhidups -DD -u root -a tl6000 Checking device (09AE/4002) (001/003) - VendorID: 09ae - ProductID: 4002 - Manufacturer: Tripp Lite - Product: TRIPP
2020 Mar 25
0
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
On 3/25/20 3:31 PM, David Zomaya wrote: > Just to confirm, it sounds like you are looking at the SU5000RT4UHV, > correct? > > https://www.tripplite.com/smartonline-208-240v-5kva-4.5kw-double-conversion-ups-4u-rack-tower-extended-run-snmpwebcard-option-usb-db9-serial~SU5000RT4UHV > That does seem to be the one they are quoting, yes. thanks, nomad
2020 Mar 25
0
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
I'm obviously biased but I like Tripp Lite stuff. I try to pitch in and help with Network UPS Tools issues related to Tripp Lite when I can too (albeit the developers and users on this list are usually more helpful than me). Just to confirm, it sounds like you are looking at the SU5000RT4UHV, correct?
2008 Dec 31
2
Unknown product ID for Tripp-Lite UPS (SU1500RTXL2UA)
To all, I attempted to configure the UPS tools for the Tripp-Lite SmartOnline 1500VA 2U rackmount UPS. I followed the instructions from the 'upsdrvctl start' output and posted the diagnostic information below. Is my UPS using an unknown product ID as reported? From the mailing list archive, I have found another posting for the same UPS with device model '09AE/4003', whereas
2020 Mar 25
2
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
Thanks. I haven't used that unit specifically with Network UPS Tools, but have used similar (from a protocol perspective) units. I'm working remotely for a while, but on the off chance I get into the position to connect a unit via USB, what Operating System are you using? If the opportunity arises, I can try to set up a basic test. Thank you, David Zomaya Business/Quality Analyst-
2007 Dec 30
1
Constant "on battery" and "on line power" status changes
Good afternoon all, I have a Tripp-Lite SmartOnline SU1500RTXL2ua UPS that I had previously tried to get up and running with NUT earlier this year. Peter Selinger had been working with this, but he had to devote time to more important things, and I did too, so it got pushed to the back burner. I saw in the release announcement of 2.2 that the UPS is now supported and decided I would try once
2003 Apr 04
2
Bug in %in% (match)
Hi, Am I hitting some limit in match? Consider the following example: > tst<-seq(100,125,by=.2)%in%seq(0,800,by=.1) > sum(tst) [1] 76 > seq(100,125,by=.2) [1] 100.0 100.2 100.4 100.6 100.8 101.0 101.2 101.4 101.6 101.8 102.0 102.2 [13] 102.4 102.6 102.8 103.0 103.2 103.4 103.6 103.8 104.0 104.2 104.4 104.6 [25] 104.8 105.0 105.2 105.4 105.6 105.8 106.0 106.2 106.4 106.6 106.8