Displaying 20 results from an estimated 900 matches similar to: "[PRI] TE110P"
2011 Jan 21
4
Does Asterisk support NI-1 (DMS 100) and NI-2 for T1s?
Hi list,
For a client I am setting up a system which will use T1 PRI from Primus, who
offer only NI-1 and NI-2 protocols for D-Channels. Previousely I have only
used switchtypes euroISDN and National. Although the documentation says
Asterisk does support NI-1 ans NI-2, but wanted to get your opinion if you
have used these protocols on an Asterisk box and if there were any things to
consider. If
2006 Apr 27
5
PRI configuration
Hi,
I am getting this message on the * console on my first pri span. Pri
show span show it is down, and I can't make any calls from the span.
Apr 27 07:40:23 NOTICE[23988]: chan_zap.c:8202 pri_dchannel: PRI got
event: HDLC Abort (6) on Primary D-channel of span 1
Apr 27 07:40:23 NOTICE[23988]: chan_zap.c:8202 pri_dchannel: PRI got
event: HDLC Abort (6) on Primary D-channel of span 1
Apr 27
2005 Sep 14
1
TE110P - Asterisk@Home Install Problems
I am having problems sending and receiving calls over the T1. They never seem to connect - outbound keeps ringing, inbound gets busy. The T1 looks ok - no errors on the line. Any ideas on what is wrong? I have tried a variety of fxsks and fxoks configurations without avail. This is a single asterisk@home system with a single T1 card. Robbed Bit T1 ami, d4.
------------------inbound call
2003 Nov 10
2
ISDN TBCT....
Greetings,
This may be a bit arcane but does anyone know what the contents of a facility message should be for initiating a TBCT on an NI2 ISDN. I've been trying to get it to work on a DMS100 for the last four months to no avail. The message I am currently sending makes it to the switch but is returned with unknown message. Perhaps someone here has done it before and can help me out.
2009 Nov 06
1
Best dahdi switchtype to emulate (network side)?
We are connecting a new device to our voice system, and the vendor has
a whole list of "supported" network devices and associated parameters
for the Telco to adjust... Yes, it's the telcos issue... Anyway, out
of all of the swtich types that dahdi can emulate, what is the most
complete/tunable solution?
The premise for those interested is a PRI connection to a Dialogic
card,
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable
in Omaha using a T100P (installed but not yet configured). While discussing
the interface parameters with a very knowledgable Cox engineer, we decided
on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits
of called number forwarded to *, and switchtype=national (NI2). They
indicated their CO switch is a
2005 Feb 23
5
Difference between E1 and PRI
Hi all,
I have seen the term E1 and PRI used interchangably when referring to
a voice service with 30B channels and 1 D channel. Are they just
different terms for the same thing or is there some technical
difference. Even Newton's telco dictonary seemed a bit fuzzy on this
topic. I have seen it said the PRi is a protocol that runs on top of
E1. Is this true?
2007 Aug 21
2
compatibility of PRI Two B channel transfers TBTC/2BTC
Hello,
A client has asked for Two B channel Transfer capability (known as
TBCT or 2BCT, similar to other features such as ECT, RTL and Q,SIG
Path Replacement) in a new Asterisk system and so I researched the
capability and came up with quite a few gaps in documentation.
2006 Mar 22
3
PRI DMS100 -> Nortel Meridian Option 81
Hello all,
I have Asterisk 1.2.1 and a TE110P connected to a Nortel Meridian Option
81C system. The PRI line is currently setup as DMS100. Here are the
relevant lines from zaptel.conf and zapata.conf:
zaptel.conf:
span=1,1,0,esf,b8zs
bchan=1-23
dchan=24
loadzone = us
defaultzone = us
zapata.conf:
[channels]
language=en
context=from-internal
musiconhold=default
switchtype=dms100
2005 Aug 09
3
First PRI
Hello All,
I am getting my first PRI installed in a couple of weeks and I wanted to
ask for a little advice. I have a single span Digium card I will be
using for the install.
Id there a benefit to which protocol I use? When asked, I told them to
set it up as NI2. The PRI is through MCI and will be used for local and
long distance with DIDs and features like CallerID, etc.
Any advice would be
2009 Mar 27
1
General help for a function I'm attempting to write
Hello,
I have written a small function ('JostD' based upon a recent molecular
ecology paper) to calculate genetic distance between populations (columns in
my data set). As I have it now I have to tell it which 2 columns to use (X,
Y). I would like it to automatically calculate 'JostD' for all combinations
of columns, perhaps returning a matrix of distances. Thanks for any help
2006 Jun 08
6
revisit to legacy PBX and CID over PRI
My legacy PBX accepts CID number, but not name.
My old PRI vendor never sent the name, so there was never an issue.
I have wedged asterisk between the Legacy PBX and PSTN. PSTN - PRI - asterisk - PRI - Legacy.
Any calls from asterisk (sip and iax extensions) which have callerID set, will not connect.
The legacy PBX hangs up, but asterisk thinks that it is still ringing.
I have added
2007 Aug 06
4
low-level dump for PRI dchan debugging
I've been going back and forth with my telco for several days, trying
different configurations to get a new PRI to come up. The bchannels
are all up and the T1 is not in alarm status. The dchannel refuses to
come up however. We've tried ni2, qsig, and now dms100 for the
switchtype. The telco tech I've been working with says that he's been
sending "reset all channels"
2008 Jun 09
1
Long call setup with non-PRI T1
We have 2 T1's coming from our phone switch to a digium TE220B. We have
managed to get CPN and the extension outpulsed from the switch, but call
setups are really slow.
Our T1's are set up as E&M Wink, and they send us the last 5 digits
dialed followed by the 10 digit calling party number (we couldn't get
the switch to be happy with *CPN*+5* to use featd).
We are using asterisk
2007 Feb 28
4
Help: CallerID Name not being sent on outbound PRI trunk
Outbound calls on my Telus PRI aren't taking the Name portion of the
callerID. I've looked at the logs, and it is being set (see below), but
the PRI debug output doesn't show the name being sent anywhere. As a
result, received calls always display from Unknown (or just the number).
Is there some config that I've missed somewhere?
I'm running NI-1 (Telus says NI-2 doesn't
2009 Mar 27
3
AT&T PRI Install - What is outpulsed?
Hey All,
AT&T is installing a PRI in a couple weeks and while I've been doing
homework on PRI's for the last few weeks there's something I'm still
confused about. After being asked how many digits I wanted them to send
us (10) was how many digits will you outpulse to us, 4, 7 or 10? I asked
her what that meant and all I got was the question repeated. Do any of
you have
2004 Dec 03
8
Why, why, why???
Help.
Why is it that I can call out from my GSBudgetone SIP phone but the
audio is "one-way'?
Why is it that when I call my asterisk phone number, I get a fast busy?
2004 Sep 24
2
What type of PRI setup is best
I am having my colo set up 2 PRI's for my new asterisk implementation. They
asked the following...
##SNIP##
What type (NI2, NTI, 4ESS, or 5ESS) and whether they want to be USER or
NETWORK.
If the equipment is flexible, NI2, with us as NETWORK is preferred.
##SNIP##
We are using a digium quad span T1 card. What is the recommended setup?
Thanks,
Chris
2006 Apr 04
1
Ideal setup for PRI/T1 and TE110P
Hi all, I'm sure something similar has been discussed, but one can only
wade through the archives for so long.
I'm setting up a T1 and my telco has a bunch of questions it wants me to
answer. I know much of the TE110p is configurable to do any of this, but
I wanted to know if there is an optimal or preferred setup.
Any help would be appreciated. Here is the quiz my telco is giving me:
2003 Aug 18
8
PRI Question
I managed to get Asterisk working with my PBX using T1, now I am moving
on to trying to make PRI work.
I have my zaptel.conf and zapata.conf configured as follows:
Zaptel.conf:
span=1,1,0,esf,b8zs
bchan=1-23
dchan=24
loadzone=us
defaultzone=us
Zapata.conf:
[channels]
transfer=yes
immediate=yes
callprogress=yes
language=en
context=default
switchtype=national
signalling=pri_net
group=1