2005 Aug 09
1
TE110P flashing red/green when PRI connected ... continued
Perhaps everything isn't as spiffy as I thought When running zttool the card still reports as internally clocked Zaptel.conf: # Global data span=1,1,0,ccs,hdb3,crc4 bchan=1-15 dchan=16 bchan=17-31 loadzone=se defaultzone=se And as pointed out by Peter I do get a lot of D-channel warnings ... Aug 9 16:21:25 NOTICE[1350]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 And
2005 Mar 15
1
PRI Card TE110p Question
Good Day list, I am having some issues with my card in that it wants to share IRQ's with everything else in my box. I am running WhiteBox Linux 3.0 Is there a way to tell linux to assign a specific IRQ to a card. (unfortunately my MB does not have feature of assigning IRQ to slot) Further, I know this is silly to even ask but I
2005 Jan 25
1
TE110P yellow errors
Hi All, I have a TE110P in E1 mode, in a dell poweredge 250. The 30 channel E1 supplied is from a telco in Australia, with the following in my zaptel.conf: span=1,1,0,ccs,hdb3 bchan=1-15 dchan=16 bchan=17-31 (yes the provider has NOcrc4 for some reason) After installing the latest cvs libpri and zaptel, I successfully loaded the kernel modules. The card is verified as not sharing an
2005 Mar 11
2
Re: Incoming echo cancel
Same problem here: if call come over ISDN PRI and it is for a SIP phone that equals to strong echo situation, at the SIP end. Interestingly this doesn't happen on all calls but it does on 95% of them. Asterisk load at that moment is insignificant - 1 to 2 calls. I have tried with all possible echo cancellers in zconfig.h, with and without MMX, and with and without CFLAGS+=-march=i686 in
2005 Jan 26
0
Getting a Wildcard TE110P working on E1's in Australia
Hello All, I have got my TE110P working at the hardware level, turned out to be a dodgy cable causing the Yellow errors in zttool. However, now I am getting yellow errors in asterisk, but zttool shows nothing out of the ordinary. here is my current config, and some asterisk console errors, any suggestions most welcome. zaptel.conf span=1,1,0,ccs,hdb3 bchan=1-15 dchan=16 bchan=17-31
2007 Oct 24
7
Compatibility Issues with dell poweredge 1950 and TE110P card
Has anyone had any compatibility issues with a TE110P card installed on a Dell Poweredge 1950? I noted the following error on the LCD display of the Dell Poweredge 1950: E1711 PCI PErr Slot 1 E171F PCIE Fatal Error B0 D4 F0. The Dell hardware owners manual states that it means the system BIOS has reported a PCI parity error on a component that resides in PCI configuration space at bus 0,
2005 Jul 27
0
R: TE110P Cable Pin Out
I think you can use normal network cable, I'm from Italy and it's work perfectly Good luck -----Messaggio originale----- Da: asterisk-users-bounces@lists.digium.com [mailto:asterisk-users-bounces@lists.digium.com] Per conto di Milo? Kocbek Inviato: mercoled? 27 luglio 2005 10.04 A: Asterisk Users Mailing List - Non-Commercial Discussion Oggetto: Re: [Asterisk-Users] TE110P Cable Pin Out
2007 Apr 27
0
Problems with Digium TE110P
Hi everyone I have a Digium card TE110P and after plug it, turn on the computer and configure, the LEDs don't light up in spite of what Digium FAQ says about the LEDs: When will the LED's light up on my TDM400P/TE110P/TE2XXP/TE4XXP? ... The TE110P LED's will light up RED when the span is configured and kernel module is loaded. If configured correctly and a circuit or channel bank is
2007 Jul 22
0
te110p stays in red alarm
Folks, I installed a te110p to connect to an E-1. Ensured the jumper is on for E-1, installed the card, and got the following from the phone company: hdb3 encoding (verbally confirmed ccs) euroisdn switchtype pri signalling So I set up zaptel.conf: span=1,1,0,ccs,hdb3 bchan=1-15 unused=17-31 dchan=16 loadzone=us defaultzone=us Card tries to come up but goes into RED alarm. Occasionally cycles
2005 Sep 26
0
TE110P Hanging up & sometimes not picking up on E&M T1
I'm getting unstable behavior with my newly installed TE110P T1 card. It hangs up any incoming call anywhere from 20 seconds to 6 minutes. Frequently, when you call back on our incoming T1 there'll be an automated announcement (maybe from the telco?) stating "we are unable to complete your call at this time". I simultaeously get a yellow alarm on the system and shortly
2006 Apr 04
1
Ideal Setup for T1/PRI and TE110P - second try
Hi all, I'm sure something similar has been discussed, but one can only wade through the archives for so long. I'm setting up a T1 and my telco has a bunch of questions it wants me to answer. I know much of the TE110p is configurable to do any of this, but I wanted to know if there is an optimal or preferred setup. Any help would be appreciated. Here is the quiz my telco is giving me:
2006 Apr 10
7
te110p and interrupts
Guys. I have an issue with a te110p card and also some tdm04b cards on the same system: Zttest returns this for the tdm04b cards: [root@mollendo ~]# /usr/src/zaptel-1.2.4/zttest 38 -v Opened pseudo zap interface, measuring accuracy... 8192 samples in 8191 sample intervals 99.987793% 8192 samples in 8192 sample intervals 100.000000% 8192 samples in 8192 sample intervals 100.000000% 8192 samples
2008 Jun 11
2
TE110P with 40,000 IRQ missess
I have an Asterisk server that was running fine until Sunday. Monday there was a power outage and the server was off most of the day. This server has a TE110P, two TDM04B and an Astribank 32. Today I noticed that the TE110P started having IRQ missess. Before today it only had about two or three per month. Today, this is the miss count after ten minutes on: IRQ Misses: 1443
2006 Apr 04
1
Ideal setup for PRI/T1 and TE110P
Hi all, I'm sure something similar has been discussed, but one can only wade through the archives for so long. I'm setting up a T1 and my telco has a bunch of questions it wants me to answer. I know much of the TE110p is configurable to do any of this, but I wanted to know if there is an optimal or preferred setup. Any help would be appreciated. Here is the quiz my telco is giving me:
2005 Aug 30
1
TE110p and E1
Hi All, I have configure my Asterisk as follow (using Asterisk@home): [zaptel.conf] span=1,1,0,ccs,hdb3,yellow bchan=1-15,17-31 dchan=16 loadzone = uk defaultzone=uk [zapata.conf] [channels] switchtype=euroisdn pridialplan=local prilocaldialplan=local internationalprefix=00 nationalprefix=0 usecallingpres=yes busydetect=no ; not need on pri callprogress=no ; was yes but wiki says experimatley
2007 Feb 07
9
Digium TE110P
Helo, I have problem with Digium TE110P connected to CISCO 3640 (port on NM-HDV-2E1-60) wth PRI E1 link. I use CISCO now for testing but when I tried with real PBX problem was exactly same. I have this messages in Asterisk conole and log sometimes: NOTICE[1115] chan_zap.c: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Usually 2-5 such messages in series, can be repeated after 10
2007 Feb 26
3
Yellow or Red alarm on TE110P ????
i get this message with a red signal on TE110P card: ***************** TE110P: span configured for... Calling startuo (flug is 4099) wcte1xxp: Setting yellow alarm ***************** what does mean ? thank you :)
2007 Sep 19
2
Supermicro PDSME+ and TE110P
Hello all, Has anyone use the Supermicro PDSME+ in combination with the TE110P successfully? My experience so far is not very good. I am running trixbox 2.0 but: 1) with zttool I am getting IRQ Misses. Don't seem to have IRQ conflict, but I am now running my SATA HD in DMA. And I am not able to set it in DMA(HIO... operation not permitted) 2) With zttool the Alarm is RED 3) When I do the
2007 Jan 25
2
TE110P and HDLC problems
Hi!, this issue makes me crazy. I read a lot of docs, also * mailling list and I try a lot of things without success. Any help will be appreciated. Here is the info: Hardware: -------------------------------------------- Supermicro Server with motherboard X7DB8, chipset Intel 5000P, Xeon 5050 Digium TE110P Software --------------------------------------------- Asterisk version 1.2.12.1
2007 Apr 06
0
Yellow alarm TE110P with latest release
Hello Approximately every 15 minutes I'm getting the following error (on all channels): [Apr 7 01:34:27] WARNING[6530]: chan_zap.c:6628 handle_init_event: Detected alarm on channel 31: Yellow Alarm [Apr 7 01:34:27] WARNING[6529]: chan_zap.c:2388 pri_find_dchan: No D-channels available! Using Primary channel 16 as D-channel anyway! [Apr 7 01:34:27] == Primary D-Channel on span 1 up