Displaying 20 results from an estimated 8000 matches similar to: "Two zaptel T1 cards: no clock from one"
2012 Dec 21
2
dahdi timing source multiple cards
I have a box with 12 T1s (4 Te410P cards). The PSTN provider is reporting
slips and ask me to update the clock source. I have my system.conf set as
the following but when I run dahdi_scan only the ports on Card 1 are showing
up with syncsrc=1
system.conf :
span=1,1,0,esf,b8zs
bchan=2-24
mtp2=1
span=2,2,0,esf,b8zs
bchan=26-48
mtp2=25
span=3,3,0,esf,b8zs
bchan=49-72
2011 Aug 03
1
TE410P hardware problems
TE410P card down.
I have three (3) TE410P in one machine running asterisk with SS7.
My problems started last week when one of my cards started switching to E1
every time after reboot. I set the following in dahdi.conf and that solve
the problem.
/etc/modprobe.d/
options wct4xxp t1e1override=0x00
Now all 4 ports on that card is down with Red Alarm. I tried rebooting the
machine and
2004 Jul 18
1
TE405P
I'm installing TE405P card.
This is my zaptel.conf.
--------------------------------------
span=1,0,0,ccs,hdb3,crc4
span=2,1,0,ccs,hdb3,crc4
span=3,0,0,ccs,hdb3,crc4
span=4,0,0,ccs,hdb3,crc4
loadzone = us
defaultzone= us
--------------------------------------
When i modprobe wct4xxp,
--------------------------------------
PCI: Found IRQ 11 for device 02:0b.0
PCI: Sharing IRQ 11 with
2004 Nov 29
3
TE410P lights don't blink read after the module is loaded
Greetings,
According to the FAQ "When you load the module and have no
circuit/channel bank the LED's should flash red"
I get the "knight rider" lights before the module loads, but after the
modules are loaded I don't get any lights, other equipment plugged in or
not.
The card has been on my shelf a while so I wonder if it needs a firmware
upgrade ? Can the cards
2005 Jan 06
1
TE410P problem (Looping UP Span 1...)
Hi list,
We have been trying to configure a Quad Span T1 card in a system running RH9. We have followed the instructions in the Wiki and searched the mailing lists, but so far havent got any success. Cable is connected to the first span, and module is loaded. Without loading the module the LED glows in red colour, but the moment we load module, it goes off. (No red or green) .
We ran zttool
2003 Oct 14
2
T100P to Adtran TA750 - No dialtone or ring
Hello all,
I've got a T100P connected to an Adtran TA750 with a T1 crossover...
This connects to a patch panel with phone ports. The Adtran is fully
populated with FXS cards.
All I get on any phone port is a fast clicking noise... No dialtone.
Asterisk 'sees' the card, (the channels show up in /proc/zaptel).
Incoming calls are routed to the zap/x channel, but no ring.
I'm
2005 Oct 09
2
Clicks, pops and noise
Hi all,
I've got a TE410p connected via T1 to four channel banks (2 FXO and 2 FXS), no PRIs.
Some users are complaining that they hear clicks and pops on the FXS lines,
generally when they pick up the phone it's noisy. This happens only after a
while, e.g. after a fresh restart of everything, all is fine but after some time
these noises start appearing. From what I've read on the
2004 Apr 21
3
T100P + Zap Errors
I am having some difficulty getting a T100P card to work with my PRI.
When I attempt to make an outbound call via:
exten => 1004,1,Dial(Zap/g1/NPANXXXXXX)
I see the following on the asterisk console:
-- Executing Dial("SIP/sbruton-b8ce", "Zap/g1/NPANXXXXXX") in new stack
Apr 21 08:18:48 NOTICE[16401]: app_dial.c:554 dial_exec: Unable to create channel of type
2014 Jun 24
1
T1 Card RED ALARM
Hello All,
I have a Digium Wildcard TE410P Quad-Span T1 Card, when I do connect T1
lines it goes in RED. When I do connect the same line on a different Server
(Same Model T1 Card) it works fine. How do I examine/diagnose my T1 Card
for any hardware failures. I heard about loopback test , how helpful it is?
Here are my configuration
/etc/zaptel.conf
span=1,1,0,esf,b8zs
2004 Jul 05
2
T1 configuration, getting help via IRC?
In my * server I have a T100P, connected with a T1 crossover cable to an
Adtran TA750 with 2 FXO cards. After I do 'modprobe wct1xxp;ztcfg' the
alarm on the card starts blinking red. Running zttool confirmed that
yes, it is a red alarm. I've read a few previous posts on this type of
setup and I'm not too much closer. What should I be checking next? A
different cable? The
2004 Apr 22
2
Problems with ADIT600 and T100P
I am having trouble getting my T100P and ADIT 600 talking. I have 2 FXO
8 port cards in the ADIT and a T1 controller card. I have a T1 x-over
cable connecting two together. Here are copies of the relevant bits of
my zaptel.conf and Zapata.conf
Zaptel.conf
span=1,0,0,esf,b8zs
loadzone=us
defaultzone=us
Zapata.cfg
context=default
signalling=fxs_ks
group=1
channel => 1-24
My
2004 Jun 20
2
Channel Bank Frustrations
I'm trying to get a Carrier Access Corp. Channel Bank I working with a
Digium T100P without success.
What is stranger is that the status lights on the channel bank and T100P
seem to change almost each time I power cycle the channel bank or reset the
T100P.
The channel bank has three status lights: T1, Framing, Status. T1 is green,
Status is yellow, and Framing is usually red but sometime
2005 Jan 12
2
T1 Timing Slips
Does anyone know how to monitor * to see if they are receiving timing slips
on a span connected to a T100P card? I am seeing b-channel restarts quite
often and also getting "No D-channels available" warnings from time to time.
Yesterday I had all the b-channels crash during a MeetMe Conference. Not
good! This PRI is connected to an Avaya Definity PBX that is onsite and
located in the
2003 Apr 09
6
Configuring for outbound calls with PRI on T100P
I run a SIP-only shop with a 23 channel PRI and single T100P.
Here are my configs:
/etc/zaptel.conf:
span=1,0,0,esf,b8zs
bchan=1-23
dchan=24
loadzone = us
defaultzone=us
/etc/asterisk/zapata.conf
[channels]
context=default
switchtype=dms100
signalling=pri_cpe
pridialplan=unknown
rxwink=300 ; Atlas seems to use long (250ms) winks
usecallerid=no
hidecallerid=no
callwaiting=no
2004 Dec 14
2
Verizon PRI Setup Problems - Only Busy and Congestion
Hi -
We're moving up in the world to a PRI (Verizon), and I'm having some
problems with it. I'm new to this PRI thing, though, so maybe I've
just screwed up a simple config detail. I've got a TE410P on a Dell
PE1600SC (ServerWorks Chipset). The card itself has a green light for
the PRI, and Zttool shows Span1 as "OK". All I'm getting when I call
into any
2003 Dec 03
2
COnfiguring an * system for a non-profit organization
Hi,
Maybe someone has seen this before...
I've installed a new T100P, but it doesn't seem to work. I've attached
the T100P to an Adtran 750 using a crossover cable. The Adtran shows a
red alarm on the T1 interface. The Adtran has been set to factory
defaults with FXS cards in 1-3 and an FXO card in 5.
The T100P shows no signs of life--the leds are not lit. Should I be
seeing
2006 Apr 30
2
PRI Issue: D-Channel woes
Hi,
I am about to pull my hair out after trying to get our PRI up and working.
We are switching from a Cisco gateway to an Asterisk box which provides
the 23 phone lines for our office. So, because the Cisco gateway is
working I can assume I have all the settings right (b8zs, esf, dms100,
etc) and the PRI is live (because we are switching over). When dialing
from PSTN, I get busy signal. When
2011 Aug 16
1
PRI Problem
I am having a problem with a new PRI turn-up on dahdi 2.5.0 and
asterisk 1.8.5 that I have not seen before. The PRI is setup as B8ZS,
ESF and the span shows up and ok. This PRI is merely a crossover T1
going into an old DC0 class 5 switch.
I am getting the following errors over and over again
[Aug 16 10:26:10] NOTICE[8002]: chan_dahdi.c:3043
my_handle_dchan_exception: PRI got event: HDLC Bad FCS
2004 Jul 02
3
IRQ Misses and Dropped Calls?
Hello everyone,
I'm using a TE410P, no irq sharing, and all extraneous devices disabled,
such as USB, Parallel etc. I'm getting a few IRQ misses according to
ZTTOOL.
We're running a standard PRI_CPE interface and seem to be getting
dropped calls, and errors on the D-CHANNEL occasionally. The circuit
itself is very solid, it was in use on our old PBX just a few weeks ago,
never
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable
in Omaha using a T100P (installed but not yet configured). While discussing
the interface parameters with a very knowledgable Cox engineer, we decided
on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits
of called number forwarded to *, and switchtype=national (NI2). They
indicated their CO switch is a